Valid

YS/T 1122.2-2016Methods for chemical analysis of(hydro) chloroplatinic acid--Part 2: determination of palladium, rhodium, iridium, gold, silver, chromium, copper, iron, nickel, lead, tin contents--Inductivity coupled plasma mass spectrometry (English PDF)

氯铂酸化学分析方法 第2部分:钯、铑、铱、金、银、铬、铜、铁、镍、铅、锡量的测定 电感耦合等离子体质谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for YS/T 1122.2-2016 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

July 11, 2016

Implementation date

January 1, 2017

Scope

YS/T 1122.2-2016 is the English-translated version of 氯铂酸化学分析方法 第2部分:钯、铑、铱、金、银、铬、铜、铁、镍、铅、锡量的测定 电感耦合等离子体质谱法.

YS/T 1122.2-2016 — This part of YS/T 1122 specifies the determination of palladium, rhodium, iridium, gold, silver, chromium, copper, iron, nickel, lead and tin in chloroplatinic acid.

This part is suitable for the determination of palladium, rhodium, iridium, gold, silver, chromium, copper, iron, nickel, lead and tin in chloroplatinic acid.

Table 1 Determination of each element Element Measurement Range /% Element Measurement Range /% Elemental Measurement Range /% Pd 0.0001 to 0.01 Rh 0.0001 to 0.01 Ir 0.0001 to 0.01 Au 0.0001 to 0.01 Ag 0.0001 to 0.01 Cr 0.0001 to 0.01 Fe 0.0001 to 0.01 Ni 0.0001 to 0.01 Pb 0.0001 to 0.01 Cu 0.0001 to 0.01 Sn 0.0001 to 0.01

Found what you need?

Document preview — YS/T 1122.2-2016

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 15

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Principle of the method
  • 3 Reagent

Foreword

YS/T 1122 "Chloroplatinic acid chemical analysis method" is divided into the following two parts.

- Part 1. Determination of platinum content - Ammonium chloride weight method;

Part 2. Determination of palladium, rhodium, iridium, gold, silver, chromium, copper, iron, nickel, lead and tin - Inductively coupled plasma mass spectrometry.

This part is part 2 of YS/T 1122.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized.

This part of the main drafting unit. Beijing Nonferrous Metals Research Institute, Nonferrous Metals Technology and Economic Research Institute.

This part participates in the drafting unit. Jinchuan Group Co., Ltd., Research and Development Co., Ltd., Guangzhou Nonferrous Metals Research Institute, Beijing Mining and Metallurgy Research Institute, your research platinum industry Co., Ltd., Xuzhou Haotong new materials Technology Co., Ltd.

This part of the main drafters. Wang Li, Chen Yingchun, Li Na, Xiang Lei, Liu Ying, Yang Hongyu, Lv Qingcheng, Li Xikai, Shang Zaiyan, Wang Weihua, Bai Weihua, Xiong Xiaoyan, Wang Jin, Liu Runting, Li Guangli, Sun Qi, Qu Xiaoke, Xi Hongjie, Gong Weilong.

Methods for chemical analysis of chloroplatinic acid - Part 2.

Palladium, rhodium, iridium, gold, silver, chrome, copper, iron, nickel, lead, tin Determination of inductively coupled plasma mass spectrometry

1 Scope

This part of YS/T 1122 specifies the determination of palladium, rhodium, iridium, gold, silver, chromium, copper, iron, nickel, lead and tin in chloroplatinic acid.

This part is suitable for the determination of palladium, rhodium, iridium, gold, silver, chromium, copper, iron, nickel, lead and tin in chloroplatinic acid.

Table 1 Determination of each element

Element Measurement Range /% Element Measurement Range /% Elemental Measurement Range /% Pd 0.0001 to 0.01 Rh 0.0001 to 0.01 Ir 0.0001 to 0.01 Au 0.0001 to 0.01 Ag 0.0001 to 0.01 Cr 0.0001 to 0.01 Fe 0.0001 to 0.01 Ni 0.0001 to 0.01 Pb 0.0001 to 0.01 Cu 0.0001 to 0.01 Sn 0.0001 to 0.01

2 Principle of the method

The contents of rhodium, silver, copper, nickel, lead and tin were determined by using cesium as internal standard, palladium, iridium and gold.

The ruthenium was used as an internal standard to determine the signal intensity of its isotope in normal operating mode.

3 Reagent

Unless otherwise specified, only the primary reagent identified as the analytical reagent and the resistivity of not more than 18.2 Mohm · cm-1 is used in the analysis.

3.1 nitric acid (rho1.42g/mL), MOS grade.

3.2 hydrochloric acid (rho1.19g/mL), MOS grade.

3.3 Hydrochloric acid (1 1).

3.4 Hydrogen peroxide (rho1.44g/mL), MOS grade.

3.5 nitric acid (1 1), with the current distribution.

3.6 hydrochloric acid (1 4), with the current distribution.

3.7 mixed acid. 3 volumes of hydrochloric acid (3.2) and 1 volume of nitric acid (3.1) mix, with the current distribution.

3.8 silver standard storage solution. Weigh 0.5000g metal silver (wAg >= 99.99%), placed in.200mL beaker, add 30mL nitric acid (3.1), cover the surface dish, heat dissolved, cooled, into the 500mL volumetric flask, diluted with water to the mark, mix. This solution 1mL Containing 1000 µg of silver.

3.9 palladium standard storage solution. Weigh 0.1000 g of metal palladium (wPd >= 99.99%), placed in 100mL polytetrafluoroethylene beaker, add 3 mL hydrochloric acid (3.2), 1 mL nitric acid (3.1), dissolve completely at low temperature, into a 100 mL volumetric flask, add 10 mL of hydrochloric acid (3.2) Diluted with water to the mark. Mix well. 1 mL of this solution containing 1000 g of palladium.

3.10 Rhodium Standard Storage Solution. Ammonium Rhodium Dioxide [w (NH4) 3RhCl6 >= 99.99%] was previously dried in an oven at 105 ° C for 2 h and placed in a desiccator

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download YS/T 1122.2-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 1122.2-2016

$169.00