YS/T 1047.9-2015Methods for chemical analysis of copper magnetite - Part 9: Determination of metallic iron content - Sulfosalicylic acid photometric method (English PDF)
铜磁铁矿化学分析方法 第9部分:金属铁量的测定 磺基水杨酸分光光度法
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for YS/T 1047.9-2015 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
April 30, 2015
Implementation date
October 1, 2015
Scope
YS/T 1047.9-2015 is the English-translated version of 铜磁铁矿化学分析方法 第9部分:金属铁量的测定 磺基水杨酸分光光度法.
YS/T 1047.9-2015 — YS/T 1047 This section specifies the method for the determination of metallic iron content of magnetite copper. This section applies to the determination of metallic iron content of magnetite copper. Measurement range (mass fraction) of 0.012% to 0.45%.
Found what you need?
Document preview — YS/T 1047.9-2015
National Standard of the People's Republic of China
- ICS
- 73.060.10
- Classification
- D 31
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Method summary
- 4 Reagents
Foreword
YS/T 1047-2015 "Methods for chemical analysis of copper magnetite" is divided into 11 sections.
--- Part 1. Determination of copper content of 2,2'-quinoline spectrophotometry and flame atomic absorption spectrometry;
--- Part 2. Determination of total iron content of dichromate method;
--- Part 3. Copper and iron - Determination of the amount of sodium thiosulfate titration;
--- Part 4. Determination of the amount of sulfur by high frequency combustion infrared absorption spectroscopy;
--- Part 5. Determination of phosphorus content titration;
--- Part 6. copper, total iron, silica, alumina, calcium oxide, magnesium oxide, titanium oxide, manganese and phosphorus contents - wave Long-dispersive X-ray fluorescence spectrometry;
--- Part 7. copper, manganese, aluminum, calcium, magnesium, titanium and phosphorus content - Inductively coupled plasma atomic emission spectrometry;
--- Part 8. silicon dioxide content - Gravimetric method;
--- Part 9. Determination of metallic iron content of sulfonic acid spectrophotometry;
--- Part 10. Determination of the amount of ferrous oxide dichromate method;
--- Part 11. Determination of the amount of magnetic iron dichromate method.
Part is divided into 9 parts.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for the drafting of People's Republic of China Bayuquan Exit Inspection and Quarantine.
1 Scope
YS/T 1047 This section specifies the method for the determination of metallic iron content of magnetite copper.
This section applies to the determination of metallic iron content of magnetite copper. Measurement range (mass fraction) of 0.012% to 0.45%.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat of the basic methods of reproduction Laboratory use specifications and test methods GB/T 6682 Analysis GB/T 7729 chemical analysis of metallurgical products spectrophotometry General GB/T 10322.1 iron ore sampling and sample preparation methods
3 Method summary
Manually, using magnetic separation method, a sample of ethanol in the media in the magnetic and non-magnetic material was separated. Under magnetic stirring with a mercuric chloride - water Yang ethanol solution of sodium leaching of metallic iron magnetic material with sulfosalicylic acid spectrophotometric determination of metallic iron content.
4 Reagents
Unless otherwise stated, use only in the analysis confirmed analytically pure reagents and in line with two water GB/T 6682 regulations.
4.1 mercuric chloride.
4.2 sodium salicylate.
4.3 sulfosalicylic acid.
4.4 sodium acetate.
4.5 iron (wFe>=99.9%).
4.6 Ethanol (95%).
4.7 hydrogen peroxide.
4.8 pairs nitrophenol ethanol solution (1g/L).
4.9 hydrochloride (21).
4.10 hydrochloric acid (14).
4.11 mercuric chloride - ethanol solution of sodium salicylate. Weigh take 2.5g sodium mercuric chloride (HgCl2) and 3g of salicylic acid dissolved in 100mL ethanol (4.6) in.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6379.2Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 7729Chemical analysis of metallurgical products—General rule for spectrophotometric methods
- GB/T 10322.1Iron ores - Sampling and sample preparation procedures
How to Download YS/T 1047.9-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10322.1-2023 — Iron ores - Sampling and sample preparation procedures
GB/T 6379.2-2004 — Measurement methods and results -- Accuracy (trueness and precision) -- Part 2: Determine the standard methods of measurement repeatability and reproducibility of the basic method
GB/T 6379.2-2026 — Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
Secure payment via Stripe
Payments accepted
YS/T 1047.9-2015
$145.00