Valid

YS/T 1046.6-2015Methods for chemical analysis of copper slag concentrates. Part 6: Determination of aluminum oxide content. Inductively coupled plasma atomic emission spectrometry (English PDF)

铜渣精矿化学分析方法 第6部分:三氧化二铝量的测定电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 1046.6-2015 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

April 30, 2015

Implementation date

October 1, 2015

Scope

YS/T 1046.6-2015 is the English-translated version of 铜渣精矿化学分析方法 第6部分:三氧化二铝量的测定电感耦合等离子体原子发射光谱法.

YS/T 1046.6-2015 — This section YS/T 1046 specifies the method for determination of copper slag concentrate aluminum oxide content. This section applies to the determination of copper slag concentrate aluminum oxide content. Measurement range of 1.00% to 5.00%.

Found what you need?

Document preview — YS/T 1046.6-2015

National Standard of the People's Republic of China

ICS
77.120.60
Classification
H 13

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 4.1 Instruments and resolution
  • 4.2 Analysis of line

Foreword

YS/T 1046-2015 "copper slag concentrates chemical analysis method" is divided into seven sections.

--- Part 1. Determination of copper content iodometry;

--- Part 2. Determination of gold and silver atomic absorption spectroscopy and fire assay gravimetric method;

--- Part 3. Determination of sulfur content of combustion titration method;

--- Part 4. Determination of iron content dichromate method;

--- Part 5. Determination of the amount of silica silicon potassium fluoride titration;

--- Part 6. aluminum oxide content - Inductively coupled plasma atomic emission spectrometry;

--- Part 7. arsenic, antimony, bismuth, lead, zinc, magnesium oxide content - Inductively coupled plasma atomic emission spectrometry.

Part is divided into 6 sections.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

This section is responsible for drafting unit. Daye Nonferrous Metals Group Holdings Limited, Zhongtiaoshan Nonferrous Metals Group Co., Ltd.

This section is drafted. Beijing Nonferrous Metal Research Institute.

It participated in the drafting of this section. Daye Nonferrous Metals Group Holdings Co., Ltd., Tongling Nonferrous Metals Group Holdings Co., Ltd., Beijing Mine Metallurgical Research Institute, Jinchuan Group Co., Jiangxi Copper Company Limited, Zijin Mining Group Co., Ltd.

1 Scope

This section YS/T 1046 specifies the method for determination of copper slag concentrate aluminum oxide content.

This section applies to the determination of copper slag concentrate aluminum oxide content. Measurement range of 1.00% to 5.00%.

2 Method summary

Sample by the use of hydrochloric acid and nitric acid and sodium hydroxide dissolved in molten sodium peroxide, inductively coupled plasma spectrometer measured.

3 Reagents

Unless otherwise indicated, used in the analysis confirmed only for the gifted class pure reagents, the water is a water.

3.1 sodium hydroxide.

3.2 sodium peroxide.

3.3 hydrochloric acid (rho = 1.19g/mL).

3.4 nitric acid (rho = 1.42g/mL).

3.5 nitric acid (11).

3.6 hydrochloric acid (595).

3.7 Aluminum Standard stock solution. Weigh 0.1000g of aluminum (wAl>=99.99%), placed in a beaker of 200mL, 10mL of nitric acid was added (3.5), after dissolved by heating, boiling, remove the cooled and transferred to 100mL volumetric flask, dilute with water to volume, and mix. This solution containing 1mL 1000µg aluminum.

3.8 aluminum standard solution. Pipette 10.00mL aluminum standard stock solution (3.7) in 100mL volumetric flask, dilute with water to volume, and mix.

This solution 1mL containing 100µg aluminum.

3.9 Argon (wAr>=99.99%).

4 Instrument

4.1 Instruments and resolution

Inductively coupled plasma atomic emission spectrometer.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Resolution. The 200nm optical resolution of not more than 0.008nm; at 400nm optical resolution no greater than 0.020nm.

--- Instrument stability. Under optimum working conditions, with aluminum standard solution measurement 1.0µg/mL of 11 times, the light intensity of the phase the standard deviation does not exceed 2.5%.

4.2 Analysis of line

Analysis line wavelength aluminum elements recommended as 396.125nm.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 1046.6-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included