YS/T 1028.5-2015Methods for chemical analysis of lithium iron phosphate. Part 5: Determination of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, manganese content. Inductively coupled plasma atomic emission spectrometry (English PDF)
磷酸铁锂化学分析方法 第5部分:钙、镁、锌、铜、铅、铬、钠、铝、镍、钴、锰量的测定 电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for YS/T 1028.5-2015 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of PRC
Level / Type
National · Recommended
Issue date
April 30, 2015
Implementation date
October 1, 2015
Scope
YS/T 1028.5-2015 is the English-translated version of 磷酸铁锂化学分析方法 第5部分:钙、镁、锌、铜、铅、铬、钠、铝、镍、钴、锰量的测定 电感耦合等离子体原子发射光谱法.
YS/T 1028.5-2015 - This part of YS/T 1028 specifies the determination method of the content of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium iron phosphate.
This part applies to the determination of the content of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium iron phosphate.
The measurement range is shown in Table 1. Table 1 -- Measuring range of each element
Found what you need?
Document preview — YS/T 1028.5-2015
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 71
Issued by: Ministry of Industry and Information Technology of PRC
Contents
- Foreword...3
- 1 Scope...4
- 2 Method summary...4
- 3 Reagents...4
- 4 Instruments...5
- 5 Samples...6
- 6 Analysis steps...6
- 7 Calculation...7
- 8 Precision...7
- 9 Test report...9
Foreword
YS/T 1028 Methods for chemical analysis of lithium iron phosphate consists of 5 parts.
-- Part 1.Determination of total iron content - Titanium trichloride reduction
potassium dichromate titration methods;
-- Part 2.Determination of lithium content - Flame photometry;
-- Part 3.Determination of phosphor content - Quinoline phosphomolybdate
gravimetry;
-- Part 4.Determination of carbon content - High frequency combustion with
infrared absorption method;
-- Part 5.Determination of calcium, magnesium, zinc, copper, lead, chromium,
sodium, aluminium, nickel, cobalt and manganese content - Inductively coupled
plasma atomic emission spectrometry
This part is Part 5 of YS/T 1028.
This part was drafted in accordance with the rules given in GB/T 1.1-2009.
This part was proposed and shall be under the jurisdiction of the National Technical
Committee on Nonferrous Metals of Standardization Administration of China
(SAC/TC243).
Drafting organizations of this part. Guangdong Brunp Recycling Technology Co., Ltd.,
Beijing General Research Institute of Mining & Metallurgy, General Research Institute
of Nonferrous Metals, Guangzhou Research Institute of Nonferrous Metals.
Main drafters of this part. Li Changdong, Yu Haijun, Xie Yinghao, Zhang Xuemei, Feng
Xianjin, Jiang Qiutao, Zhang Diankai, Ding Hao, Xiong Xiaoyan, Wang Jin.
Methods for chemical analysis of lithium iron phosphate -
Part 5.Determination of calcium, magnesium, zinc, copper,
lead, chromium, sodium, aluminium, nickel, cobalt,
manganese content - Inductively coupled plasma atomic
emission spectrometry
1 Scope
This part of YS/T 1028 specifies the determination method of the content of calcium,
magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and
manganese in lithium iron phosphate.
This part applies to the determination of the content of calcium, magnesium, zinc,
copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium
iron phosphate. The measurement range is shown in Table 1.
Table 1 -- Measuring range of each element
2 Method summary
The sample is dissolved with hydrochloric acid, the carbon in it is filtered out, and the
element to be measured is measured by using an inductively coupled plasma atomic
emission spectrometer.
3 Reagents
3.1 Hydrochloric acid (guaranteed reagent, rho~1.19 g/mL).
Element Element Measuring range w / % Measuring range w / %
3.2 Hydrochloric acid (1+1).
3.3 Hydrochloric acid (1+19).
4 Instruments
Inductively coupled plasma atomic emission spectrometer.
Under the best working conditions of the instrument, any instrument that can achieve
the following indexes can be used.
5 Samples
The particle size of the sample shall not be larger than 0.10 mm.
6 Analysis steps
6.1 Specimen
Weigh the sample (Chapter 5) according to Table 3, accurate to 0.0001 g.
6.2 Number of measurements
Weigh 2 specimens, conduct parallel measurements, and take the average value.
6.3 Blank test
Do a blank test along with the specimen.
6.5 Drawing of working curve
Accurately pipette 0 mL, 0.40 mL, 1.00 mL, 2.00 mL, 5.00 mL, 10.00 mL, and 20.00
mL of mixed standard solution (3.5) into 100 mL volumetric flasks, dilute to the mark
with hydrochloric acid (3.3), and mix well. On the ICP spectrometer with optimized
parameters, measure the spectral intensity of each element such as calcium, magnesium,
zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, and manganese, and
draw a working curve.
6.6 Determination
Mass fraction / % Specimen / g Test solution volume / mL
On the ICP spectrometer with optimized parameters, measure the spectral intensity of
calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt,
7 Calculation
The content of the element to be measured is calculated based on the mass fraction wx
of the element to be measured, and the value is expressed in % and calculated according
to formula (1).
8 Precision
8.1 Repeatability
The measured values of two independent test results obtained under repeatability
conditions are within the average value range given below; the absolute difference
between the two test results does not exceed the repeatability limit (r), the probability
of exceeding the repeatability limit (r) does not exceed 5%, and the repeatability limit
(r) is obtained by linear interpolation according to the data in Table 4.
9 Test report
The test report shall include the following content.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
How to Download YS/T 1028.5-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 1028.1-2015 — Methods for chemical analysis of lithium iron phosphate. Part 1: Determination of total iron content. Titanium trichloride reduction potassium dichromate titration methods
YS/T 1028.2-2015 — Methods for chemical analysis of lithium iron phosphate. Part 2: Determination of lithium content. Flame photometry
YS/T 1028.4-2015 — Methods for chemical analysis of lithium iron phosphate. Part 4: Determination of carbon content. High frequency combustion with infrared absorption method
Secure payment via Stripe
Payments accepted
YS/T 1028.5-2015