YS/T 1006.2-2014Methods for Chemical Analysis of Lithium Nickel Cobalt Manganese Oxide - Part 2: Determination of Lithium, Nickel, Cobalt, Manganese, Sodium, Magnesium, Aluminum, Potassium, Copper, Calcium, Iron, Zinc and Silicon Content - Inductively Coupled Plasma Atom (English PDF)
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for YS/T 1006.2-2014 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of the People’s Republic of China
Level / Type
National · Recommended
Issue date
October 14, 2014
Implementation date
April 1, 2015
Scope
YS/T 1006.2-2014 (Methods for Chemical Analysis of Lithium Nickel Cobalt Manganese Oxide - Part 2: Determination of Lithium, Nickel, Cobalt, Manganese, Sodium, Magnesium, Aluminum, Potassium, Copper, Calcium, Iron, Zinc and Silicon Content - Inductively Coupled Plasma Atom) is available as an English-translated PDF.
YS/T 1006.2-2014 — This Part of YS/T 1006 specifies the method for the determination of lithium, nickel, cobalt, manganese, sodium, magnesium, aluminum, potassium, copper, calcium, iron, zinc and silicon content in lithium nickel cobalt manganese oxide, which is the cathode material for lithium ion batteries.
This Part is applicable to the determination of lithium, nickel, cobalt, manganese, sodium, magnesium, aluminum, potassium, copper, calcium, iron, zinc and silicon content in lithium nickel cobalt manganese oxide, which is the cathode material for lithium ion batteries. The range of determination is shown in Table 1.
Found what you need?
Document preview — YS/T 1006.2-2014
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 14
Issued by: Ministry of Industry and Information Technology of the People’s Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Method Summary...5
- 3 Reagents...5
- 4 Instrument...8
- 5 Specimen...9
- 6 Analytical Procedures...9
- 7 Calculation of Analysis Result...10
- 8 Precision...11
- 9 Test Report...12
Foreword
YS/T 1006-2014 Methods for Chemical Analysis of Lithium Nickel Cobalt Manganese
Oxide is divided into 2 parts.
---Part 1.Determination the Total of Nickel Cobalt Manganese Content - EDTA
Disodium Salt Titration;
---Part 2.Determination of Lithium, Nickel, Cobalt, Manganese, Sodium,
Magnesium, Aluminum, Potassium, Copper, Calcium, Iron, Zinc and Silicon
Content - Inductively Coupled Plasma Atomic Emission Spectrometry.
This is Part 2 of YS/T 1006.
This Part shall be under the jurisdiction of National Technical Committee on Non-
ferrous Metals of Standardization Administration of China (SAC/TC 243).
The drafting organizations of this Part. CITIC GUOAN MGL Power Science &
Technology Co., Ltd.; Guangdong BRUNP Recycling Technology Co., Ltd.; Jining
Wujie Science & Technology Co., Ltd.; Shenzhen Tianjiao Technology Development
Co., Ltd.
1 Scope
This Part of YS/T 1006 specifies the method for the determination of lithium, nickel,
cobalt, manganese, sodium, magnesium, aluminum, potassium, copper, calcium, iron,
zinc and silicon content in lithium nickel cobalt manganese oxide, which is the cathode
material for lithium ion batteries.
This Part is applicable to the determination of lithium, nickel, cobalt, manganese,
sodium, magnesium, aluminum, potassium, copper, calcium, iron, zinc and silicon
content in lithium nickel cobalt manganese oxide, which is the cathode material for
lithium ion batteries. The range of determination is shown in Table 1.
2 Method Summary
Use hydrochloric acid to dissolve the specimen. In the hydrochloric acid medium, in
accordance with the optimized operating conditions of the instrument and the
recommended analytical spectrums, adopt the working curve method and an
inductively coupled plasma atomic emission spectrometer to determine the lithium,
nickel, cobalt, manganese, sodium, magnesium, aluminum, potassium, copper,
calcium, iron, zinc and silicon content, in which, the determination of the lithium, nickel,
cobalt and manganese content is conducted by adding yttrium standard solution as an
internal standard.
3 Reagents
Unless it is otherwise specified, only reagents of top-grade purity and Grade-2 (and
above) water are used in the analysis.
3.5 Internal standard solution. weigh-take 2.5400 g of yttrium trioxide [w(Y2O3) >= 99.99%]
in a beaker; add 30 mL of hydrochloric acid (3.3). Heat it up to dissolve it, then, remove
it and cool it down. Use water to wash the watch glass and the wall of the beaker;
transfer it into a 1,000 mL volumetric flask. Use water to dilute it to the scale, then, mix
it up. 1 mL of this solution contains 2 mg of yttrium.
3.8 Cobalt standard stock solution. weigh-take 1.0000 g of pure cobalt [w(Co) >= 99.99%]
in a beaker; add 50 mL of hydrochloric acid (3.3). Heat it up to dissolve it, then, remove
it and cool it down. Use water to wash the watch glass and the wall of the beaker;
transfer it into a 500 mL volumetric flask. Use water to dilute it to the scale, then, mix it
up. 1 mL of this solution contains 2.0 mg of cobalt.
3.9 Manganese standard stock solution. weigh-take 1.0000 g of pure manganese [w(Mn)
>= 99.99%] in a beaker; add 50 mL of hydrochloric acid (3.3). Heat it up to dissolve it,
then, remove it and cool it down. Use water to wash the watch glass and the wall of
the beaker; transfer it into a 500 mL volumetric flask. Use water to dilute it to the scale,
then, mix it up. 1 mL of this solution contains 2.0 mg of manganese.
3.10 Sodium standard stock solution. weigh-take 2.5420 g of dried reference sodium
chloride [w(NaCl) >= 99.99%] in a beaker; slowly add 100 mL of water and cover the watch
glass. Conduct low-temperature dissolution, then, cool it down. Use water to wash the
watch glass and the wall of the beaker; transfer it into a 1,000 mL volumetric flask. Use
water to dilute it to the scale, then, mix it up; immediately transfer it to a dry plastic
bottle. 1 mL of this solution contains 1.0 mg of sodium.
3.11 Magnesium standard stock solution. weigh-take 1.6580 g of dried magnesium
oxide [w(MgO) >= 99.99%] in a beaker; slowly add 50 mL of hydrochloric acid (3.3) and
cover the watch glass. Conduct low-temperature dissolution, then, cool it down. Use
water to wash the watch glass and the wall of the beaker; transfer it into a 1,000 mL
volumetric flask. Use water to dilute it to the scale, then, mix it up. 1 mL of this solution
contains 1.0 mg of magnesium.
3.13 Potassium standard stock solution. weigh-take 1.9068 g of dried reference
potassium chloride [w(KCl) >= 99.99%] in a beaker; slowly add 100 mL of water and cover
the watch glass. Conduct low-temperature dissolution, then, cool it down. Use water
to wash the watch glass and the wall of the beaker; transfer it into a 1,000 mL
volumetric flask. Use water to dilute it to the scale, then, mix it up; immediately transfer
it to a dry plastic bottle. 1 mL of this solution contains 1.0 mg of potassium.
3.16 Iron standard stock solution. weigh-take 1.0000 g of pure iron [w(Fe) >= 99.99%] in
a beaker; slowly add 50 mL of hydrochloric acid (3.3) and cover the watch glass.
Conduct low-temperature dissolution, then, remove it and cool it down. Use water to
wash the watch glass and the wall of the beaker; transfer it into a 1,000 mL volumetric
flask. Use water to dilute it to the scale, then, mix it up. 1 mL of this solution contains
1.0 mg of iron.
3.17 Zinc standard stock solution. weigh-take 1.0000 g of pure zinc [w(Zn) >= 99.99%] in
a 400 mL beaker; slowly add 50 mL of nitric acid (3.4) and cover the watch glass.
Conduct low-temperature dissolution to drive off nitrogen oxides, then, remove it and
cool it down. Use water to wash the watch glass and the wall of the beaker; transfer it
into a 1,000 mL volumetric flask. Use water to dilute it to the scale, then, mix it up. 1
mL of this solution contains 1.0 mg of zinc.
3.18 Silicon standard stock solution. weigh-take 2.1395 g of pure silicon oxide [w(SiO2)
>= 99.99%] in a platinum crucible; add 15 g of anhydrous sodium carbonate; mix it up
and cover it. Then, transfer it into a 400 °C muffle furnace; raise the temperature to
900 °C and melt it for 1 h; take it out and cool it down. Use water to wash the inner wall
of the crucible; place it in a PTFE plastic beaker. Add 100 mL of hot water; conduct
low-temperature dissolution, then, cool it down. Transfer it into a 1,000 mL volumetric
flask. Use water to dilute to the scale, then, mix it up; immediately transfer it to a dry
plastic bottle. 1 mL of this solution contains 1.0 mg of silicon.
3.19 Mixed standard solution A. respectively transfer-take 10.00 mL of sodium
standard stock solution (3.10), magnesium standard stock solution (3.11), aluminum
standard stock solution (3.12), potassium standard stock solution (3.13), copper
standard stock solution (3.14), calcium standard stock solution (3.15), iron standard
stock solution (3.16) and zinc standard stock solution (3.17); place it in a 100 mL
volumetric flask. Use hydrochloric acid (5 + 95) to dilute it to the scale, then, mix it up;
immediately transfer it to a dry plastic bottle. 1 mL of this solution contains 100 µg of
sodium, magnesium, aluminum, potassium, copper, calcium, iron and zinc.
3.20 Mixed standard solution B. transfer-take 10.00 mL of mixed standard solution A
(3.19); place it in a 100 mL volumetric flask. Use hydrochloric acid (5 + 95) to dilute it
to the scale, then, mix it up; immediately transfer it to a dry plastic bottle. 1 mL of this
solution contains 10 µg of sodium, magnesium, aluminum, potassium, copper, calcium,
iron and zinc.
4 Instrument
4.1 Inductively Coupled Plasma Atomic Emission Spectrometer
4.2 Analytical Spectrums
Table 2 lists out the recommended analytical spectrums.
4.4 Linearity of Working Curve
In terms of the linearity of the working curve, the correlation coefficient shall be greater
than 0.999.
5 Specimen
5.1 The specimen shall pass through a 50 µm sieve.
5.2 Before analysis, the specimen shall be dried at 110 °C ± 5°C for 2 h and placed in
a desiccator to cool down to room temperature.
6 Analytical Procedures
6.1 Specimen
Weigh-take 0.20 g of specimen, accurate to 0.0001 g.
6.2 Number of Determinations
Independently conduct two determinations; take the average value.
6.3 Blank Test
Conduct a blank test on the accompanying specimen.
6.4 Determination
6.4.1 Processing of specimen
6.4.2 Preparation of a series of standard solutions
6.4.2.1 Respectively transfer-take 0 mL, 0.60 mL, 2.00 mL, 5.00 mL, 10.00 mL, 20.00
mL, 30.00 mL and 40.00 mL of standard solution (3.20); place it in a 200 mL volumetric
flask. Use water to dilute to the scale, then, mix it up; immediately transfer it to a dry
plastic bottle.
6.4.3 Measurement
After the instrument stably operates, in accordance with the optimized operating
conditions of the instrument and the recommended analytical spectrum wavelengths
(see Table 2), use the series of standard solutions (6.4.2.1) to determine the light
emission intensity of sodium, magnesium, aluminum, potassium, copper, calcium, iron
and zinc; use the standard series of solution (6.4.2.2) to determine the light emission
intensity of silicon; use the standard series of solution (6.4.2.3) to determine the light
emission intensity of lithium, nickel, cobalt and manganese. From low to high,
determine the light emission intensity of the measured element in the standard series
of solution.
7 Calculation of Analysis Result
The content of the measured element shall be counted as mass fraction (wM),
expressed in (%) and calculated in accordance with Formula (1).
8 Precision
8.1 Repeatability
In terms of the measured value of two independent test results obtained under
repeatability conditions, the absolute difference between the two test results shall not
exceed the repeatability limit (r), and the circumstance of exceeding the repeatability
limit (r) shall not exceed 5%. The value of the repeatability limit (r) shall comply with
the data in Table 3.
8.2 Allowable Difference
The difference of the inter-laboratory analysis results shall be not greater than the
values shown in Table 4.
9 Test Report
The test report shall include the following contents.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
Referenced standards
How to Download YS/T 1006.2-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 1006.1-2014 — Methods for chemical analysis of lithium nickel cobalt manganese oxide. Part 1: Determination the total of nickel cobalt manganese content. EDTA disodium salt titration
YS/T 575.4-2025 — Methods for Chemical Analysis of Bauxite – Part 4: Determination of Iron Oxide Contents
YS/T 665-2024 — Refined aluminium ingot for remelting
Secure payment via Stripe
Payments accepted
YS/T 1006.2-2014
$150.00