YS/T 1006.2-2014Methods for Chemical Analysis of Lithium Nickel Cobalt Manganese Oxide - Part 2: Determination of Lithium, Nickel, Cobalt, Manganese, Sodium, Magnesium, Aluminum, Potassium, Copper, Calcium, Iron, Zinc and Silicon Content - Inductively Coupled Plasma Atom (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for YS/T 1006.2-2014 in 30 minutes.

Issued by

Ministry of Industry and Information Technology of the People’s Republic of China

Level / Type

National · Recommended

Issue date

October 14, 2014

Implementation date

April 1, 2015

Scope

YS/T 1006.2-2014 (Methods for Chemical Analysis of Lithium Nickel Cobalt Manganese Oxide - Part 2: Determination of Lithium, Nickel, Cobalt, Manganese, Sodium, Magnesium, Aluminum, Potassium, Copper, Calcium, Iron, Zinc and Silicon Content - Inductively Coupled Plasma Atom) is available as an English-translated PDF.

YS/T 1006.2-2014 — This Part of YS/T 1006 specifies the method for the determination of lithium, nickel, cobalt, manganese, sodium, magnesium, aluminum, potassium, copper, calcium, iron, zinc and silicon content in lithium nickel cobalt manganese oxide, which is the cathode material for lithium ion batteries.

This Part is applicable to the determination of lithium, nickel, cobalt, manganese, sodium, magnesium, aluminum, potassium, copper, calcium, iron, zinc and silicon content in lithium nickel cobalt manganese oxide, which is the cathode material for lithium ion batteries. The range of determination is shown in Table 1.

Found what you need?

Document preview — YS/T 1006.2-2014

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 14

Issued by: Ministry of Industry and Information Technology of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Method Summary...5
  • 3 Reagents...5
  • 4 Instrument...8
  • 5 Specimen...9
  • 6 Analytical Procedures...9
  • 7 Calculation of Analysis Result...10
  • 8 Precision...11
  • 9 Test Report...12

Foreword

YS/T 1006-2014 Methods for Chemical Analysis of Lithium Nickel Cobalt Manganese

Oxide is divided into 2 parts.

---Part 1.Determination the Total of Nickel Cobalt Manganese Content - EDTA

Disodium Salt Titration;

---Part 2.Determination of Lithium, Nickel, Cobalt, Manganese, Sodium,

Magnesium, Aluminum, Potassium, Copper, Calcium, Iron, Zinc and Silicon

Content - Inductively Coupled Plasma Atomic Emission Spectrometry.

This is Part 2 of YS/T 1006.

This Part shall be under the jurisdiction of National Technical Committee on Non-

ferrous Metals of Standardization Administration of China (SAC/TC 243).

The drafting organizations of this Part. CITIC GUOAN MGL Power Science &

Technology Co., Ltd.; Guangdong BRUNP Recycling Technology Co., Ltd.; Jining

Wujie Science & Technology Co., Ltd.; Shenzhen Tianjiao Technology Development

Co., Ltd.

1 Scope

This Part of YS/T 1006 specifies the method for the determination of lithium, nickel,

cobalt, manganese, sodium, magnesium, aluminum, potassium, copper, calcium, iron,

zinc and silicon content in lithium nickel cobalt manganese oxide, which is the cathode

material for lithium ion batteries.

This Part is applicable to the determination of lithium, nickel, cobalt, manganese,

sodium, magnesium, aluminum, potassium, copper, calcium, iron, zinc and silicon

content in lithium nickel cobalt manganese oxide, which is the cathode material for

lithium ion batteries. The range of determination is shown in Table 1.

2 Method Summary

Use hydrochloric acid to dissolve the specimen. In the hydrochloric acid medium, in

accordance with the optimized operating conditions of the instrument and the

recommended analytical spectrums, adopt the working curve method and an

inductively coupled plasma atomic emission spectrometer to determine the lithium,

nickel, cobalt, manganese, sodium, magnesium, aluminum, potassium, copper,

calcium, iron, zinc and silicon content, in which, the determination of the lithium, nickel,

cobalt and manganese content is conducted by adding yttrium standard solution as an

internal standard.

3 Reagents

Unless it is otherwise specified, only reagents of top-grade purity and Grade-2 (and

above) water are used in the analysis.

3.5 Internal standard solution. weigh-take 2.5400 g of yttrium trioxide [w(Y2O3) >= 99.99%]

in a beaker; add 30 mL of hydrochloric acid (3.3). Heat it up to dissolve it, then, remove

it and cool it down. Use water to wash the watch glass and the wall of the beaker;

transfer it into a 1,000 mL volumetric flask. Use water to dilute it to the scale, then, mix

it up. 1 mL of this solution contains 2 mg of yttrium.

3.8 Cobalt standard stock solution. weigh-take 1.0000 g of pure cobalt [w(Co) >= 99.99%]

in a beaker; add 50 mL of hydrochloric acid (3.3). Heat it up to dissolve it, then, remove

it and cool it down. Use water to wash the watch glass and the wall of the beaker;

transfer it into a 500 mL volumetric flask. Use water to dilute it to the scale, then, mix it

up. 1 mL of this solution contains 2.0 mg of cobalt.

3.9 Manganese standard stock solution. weigh-take 1.0000 g of pure manganese [w(Mn)

>= 99.99%] in a beaker; add 50 mL of hydrochloric acid (3.3). Heat it up to dissolve it,

then, remove it and cool it down. Use water to wash the watch glass and the wall of

the beaker; transfer it into a 500 mL volumetric flask. Use water to dilute it to the scale,

then, mix it up. 1 mL of this solution contains 2.0 mg of manganese.

3.10 Sodium standard stock solution. weigh-take 2.5420 g of dried reference sodium

chloride [w(NaCl) >= 99.99%] in a beaker; slowly add 100 mL of water and cover the watch

glass. Conduct low-temperature dissolution, then, cool it down. Use water to wash the

watch glass and the wall of the beaker; transfer it into a 1,000 mL volumetric flask. Use

water to dilute it to the scale, then, mix it up; immediately transfer it to a dry plastic

bottle. 1 mL of this solution contains 1.0 mg of sodium.

3.11 Magnesium standard stock solution. weigh-take 1.6580 g of dried magnesium

oxide [w(MgO) >= 99.99%] in a beaker; slowly add 50 mL of hydrochloric acid (3.3) and

cover the watch glass. Conduct low-temperature dissolution, then, cool it down. Use

water to wash the watch glass and the wall of the beaker; transfer it into a 1,000 mL

volumetric flask. Use water to dilute it to the scale, then, mix it up. 1 mL of this solution

contains 1.0 mg of magnesium.

3.13 Potassium standard stock solution. weigh-take 1.9068 g of dried reference

potassium chloride [w(KCl) >= 99.99%] in a beaker; slowly add 100 mL of water and cover

the watch glass. Conduct low-temperature dissolution, then, cool it down. Use water

to wash the watch glass and the wall of the beaker; transfer it into a 1,000 mL

volumetric flask. Use water to dilute it to the scale, then, mix it up; immediately transfer

it to a dry plastic bottle. 1 mL of this solution contains 1.0 mg of potassium.

3.16 Iron standard stock solution. weigh-take 1.0000 g of pure iron [w(Fe) >= 99.99%] in

a beaker; slowly add 50 mL of hydrochloric acid (3.3) and cover the watch glass.

Conduct low-temperature dissolution, then, remove it and cool it down. Use water to

wash the watch glass and the wall of the beaker; transfer it into a 1,000 mL volumetric

flask. Use water to dilute it to the scale, then, mix it up. 1 mL of this solution contains

1.0 mg of iron.

3.17 Zinc standard stock solution. weigh-take 1.0000 g of pure zinc [w(Zn) >= 99.99%] in

a 400 mL beaker; slowly add 50 mL of nitric acid (3.4) and cover the watch glass.

Conduct low-temperature dissolution to drive off nitrogen oxides, then, remove it and

cool it down. Use water to wash the watch glass and the wall of the beaker; transfer it

into a 1,000 mL volumetric flask. Use water to dilute it to the scale, then, mix it up. 1

mL of this solution contains 1.0 mg of zinc.

3.18 Silicon standard stock solution. weigh-take 2.1395 g of pure silicon oxide [w(SiO2)

>= 99.99%] in a platinum crucible; add 15 g of anhydrous sodium carbonate; mix it up

and cover it. Then, transfer it into a 400 °C muffle furnace; raise the temperature to

900 °C and melt it for 1 h; take it out and cool it down. Use water to wash the inner wall

of the crucible; place it in a PTFE plastic beaker. Add 100 mL of hot water; conduct

low-temperature dissolution, then, cool it down. Transfer it into a 1,000 mL volumetric

flask. Use water to dilute to the scale, then, mix it up; immediately transfer it to a dry

plastic bottle. 1 mL of this solution contains 1.0 mg of silicon.

3.19 Mixed standard solution A. respectively transfer-take 10.00 mL of sodium

standard stock solution (3.10), magnesium standard stock solution (3.11), aluminum

standard stock solution (3.12), potassium standard stock solution (3.13), copper

standard stock solution (3.14), calcium standard stock solution (3.15), iron standard

stock solution (3.16) and zinc standard stock solution (3.17); place it in a 100 mL

volumetric flask. Use hydrochloric acid (5 + 95) to dilute it to the scale, then, mix it up;

immediately transfer it to a dry plastic bottle. 1 mL of this solution contains 100 µg of

sodium, magnesium, aluminum, potassium, copper, calcium, iron and zinc.

3.20 Mixed standard solution B. transfer-take 10.00 mL of mixed standard solution A

(3.19); place it in a 100 mL volumetric flask. Use hydrochloric acid (5 + 95) to dilute it

to the scale, then, mix it up; immediately transfer it to a dry plastic bottle. 1 mL of this

solution contains 10 µg of sodium, magnesium, aluminum, potassium, copper, calcium,

iron and zinc.

4 Instrument

4.1 Inductively Coupled Plasma Atomic Emission Spectrometer

4.2 Analytical Spectrums

Table 2 lists out the recommended analytical spectrums.

4.4 Linearity of Working Curve

In terms of the linearity of the working curve, the correlation coefficient shall be greater

than 0.999.

5 Specimen

5.1 The specimen shall pass through a 50 µm sieve.

5.2 Before analysis, the specimen shall be dried at 110 °C ± 5°C for 2 h and placed in

a desiccator to cool down to room temperature.

6 Analytical Procedures

6.1 Specimen

Weigh-take 0.20 g of specimen, accurate to 0.0001 g.

6.2 Number of Determinations

Independently conduct two determinations; take the average value.

6.3 Blank Test

Conduct a blank test on the accompanying specimen.

6.4 Determination

6.4.1 Processing of specimen
6.4.2 Preparation of a series of standard solutions
6.4.2.1 Respectively transfer-take 0 mL, 0.60 mL, 2.00 mL, 5.00 mL, 10.00 mL, 20.00

mL, 30.00 mL and 40.00 mL of standard solution (3.20); place it in a 200 mL volumetric

flask. Use water to dilute to the scale, then, mix it up; immediately transfer it to a dry

plastic bottle.

6.4.3 Measurement

After the instrument stably operates, in accordance with the optimized operating

conditions of the instrument and the recommended analytical spectrum wavelengths

(see Table 2), use the series of standard solutions (6.4.2.1) to determine the light

emission intensity of sodium, magnesium, aluminum, potassium, copper, calcium, iron

and zinc; use the standard series of solution (6.4.2.2) to determine the light emission

intensity of silicon; use the standard series of solution (6.4.2.3) to determine the light

emission intensity of lithium, nickel, cobalt and manganese. From low to high,

determine the light emission intensity of the measured element in the standard series

of solution.

7 Calculation of Analysis Result

The content of the measured element shall be counted as mass fraction (wM),

expressed in (%) and calculated in accordance with Formula (1).

8 Precision

8.1 Repeatability

In terms of the measured value of two independent test results obtained under

repeatability conditions, the absolute difference between the two test results shall not

exceed the repeatability limit (r), and the circumstance of exceeding the repeatability

limit (r) shall not exceed 5%. The value of the repeatability limit (r) shall comply with

the data in Table 3.

8.2 Allowable Difference

The difference of the inter-laboratory analysis results shall be not greater than the

values shown in Table 4.

9 Test Report

The test report shall include the following contents.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

Referenced standards

How to Download YS/T 1006.2-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 1006.2-2014

$150.00