YD/T 6502-2025Calibration procedures of electromagnetic field sensors and probes (excluding antennas)from 9kHz to 40GHz (English PDF)
频率为9kHz~40GHz电磁场传感器和探头(不包括天线)的校准方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YD/T 6502-2025 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
July 2, 2025
Implementation date
November 1, 2025
Scope
YD/T 6502-2025 is the English-translated version of 频率为9kHz~40GHz电磁场传感器和探头(不包括天线)的校准方法.
YD/T 6502-2025 is the Chinese standard "Calibration procedures of electromagnetic field sensors and probes (excluding antennas)from 9kHz to 40GHz". This standard specifies the calibration procedures for electromagnetic field sensors and probes (excluding antennas), applicable to a frequency range of 9kHz to 40GHz.
Calibration methods for electromagnetic field sensors and probes in the DC to 9kHz and 40GHz to 90GHz ranges can be performed with reference to this document. This document defines the characteristics, use, and measurement uncertainties of electromagnetic field sensors and probes.
The scope covered includes: anisotropic effects, temperature effects, probe linearity effects, modulation effects, source and conductor proximity effects (near-field effects), responses to electromagnetic fields at multiple frequencies, and the effects of non-pure harmonic fields generated by power amplifiers when the probe or measuring instrument is partially or fully placed in the field.
This document applies to the calibration of electromagnetic field sensors and probes (excluding antennas) with frequencies from 9kHz to 40GHz. It was issued by Ministry of Industry and Information Technology. Issued on 2025-07-02, in force from 2025-11-01.
Found what you need?
Document preview — YD/T 6502-2025
National Standard of the People's Republic of China
Issued by: Ministry of Industry and Information Technology
Contents
- [Preview only]
- 1 Scope
- 2 Normative References
- 2.1 Term
- 3 Terms and Definitions
- 3.2 Abbreviations
- 3.3 Specifications
- 3.4 Product model and designation
- 3.5 Product marking
- 4 Product Classification
- 4.1 General
- 4.2 Model and name
- 4.3 Test Waveform
- 4.4 Product labelling
- 5 Requirements
- 5.2 Chemical components
- 5.3 SPD Disconnector Inspection
- 5.4 Environmental protection property
- 5.5 Material compatibility
- 5.6 Spurious emission
- 5.7 Transmit Spectrum Mask
- 5.8 Time of Rising Edge and Falling Edge
- 5.9 In-band Flatness
- 6 Test methods
- 6.2 Term restrictions
- 6.3 End-of-manufacturing inspection
- 6.4 Type inspection
- 6.5 Phone Program
- 6.6 OTASP/OTAPA Function
- 6.7 Processing of PIN
- 6.8 Fixed Dialing Number (FDN)
- 6.9 Abbreviated Dialing Number (ADN)
- 7 Inspection Rules
- 7.1 Packaging
- 7.2 Marking
- 7.3 Transport
- 7.4 Storage
- 7.5 Safety Test for Temporary Overvoltage Failure
- 7.6 Test of Temporary Overvoltage Withstand Characteristic
- 7.7 SPD Thermal Stability Test
- 8 Marking, Packing, Transport and Storage
- 8.1 Voltage Drop Test
- 8.2 Surge Withstand Capability at Load side
- 8.3 Short-circuit Withstand Capability at Load Side
- 9 Environmental Applicability Test
- 9.1 Vibration Test
- 9.2 High Temperature Test
- 9.3 Low Temperature Test
- 9.4 Alternating Humid Heat Test
- 9.5 Performance requirements for radio resource management
1 Foreword
YD/T 6502-2025 was issued by Ministry of Industry and Information Technology on 2 July 2025 and has been in force since 1 November 2025.
The YD/T prefix marks a recommended standard. It is not law in itself: it becomes binding when a contract names it, when a regulation or a mandatory standard refers to it, or when a producer declares conformity with it.
The document runs to 15 pages in English translation.
2 Scope Preview
This standard specifies the calibration procedures for electromagnetic field sensors and probes (excluding antennas), applicable to a frequency range of 9kHz to 40GHz. Calibration methods for electromagnetic field sensors and probes in the DC to 9kHz and 40GHz to 90GHz ranges can be performed with reference to this document. This document defines the characteristics, use, and measurement uncertainties of electromagnetic field sensors and probes. The scope covered includes: anisotropic effects, temperature effects, probe linearity effects, modulation effects, source and conductor proximity effects (near-field effects), responses to electromagnetic fields at multiple frequencies, and the effects of non-pure harmonic fields generated by power amplifiers when the probe or measuring instrument is partially or fully placed in the field. This document applies to the calibration of electromagnetic field sensors and probes (excluding antennas) with frequencies from 9kHz to 40GHz.
YD/T 6502-2025 carries no ICS number and no Chinese Standard Classification code.
This catalogue holds 6,667 other YD/T standards.
Of the 4,379 YD/T standards that do carry an ICS number, 3,421 (78%) fall under ICS 33, in the field of telecommunications.
3 About this standard
Sector: Telecommunication Industry Standard (Recommended)
Issued by: Ministry of Industry and Information Technology
English translation: about 15 pages (approximate)
4 Related standards
Standards on related subjects:
JB 2293-1978 — Wind tunnel test method of radiator of automobile and tractor
YD/T 4046-2022 — Cloud computing open application model
YD/T 4045-2022 — Big data - technical requirements and test methods for message middleware
YD/T 4044-2022 — Technical requirements for AI-based knowledge graph construction
5 Classification and status
Prefix YD/T: recommended standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download YD/T 6502-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YD/T 1114-2026 — Halogen-free flame retardant optical fibre cable
YD/T 1181.1-2026 — Characteristics of non-metal reinforcement used for optical fiber cables - Part 1: Glass fiber reinforced plastic rods
YD/T 1181.3-2026 — Characteristics of non-metal reinforcement for optical fiber cables - Part 3: aramid fiber reinforced plastic rods
YD/T 6502-2025
$1,085.00