YD/T 1595.1-2012Requirements and measurement methods of electromagnetic compatibility for 2GHz WCDMA digital cellular mobile telecommunications system - Part 1: user equipment and ancillary equipment (English PDF)
Also coversYDT1595.1-2012
This is a limited preview
Buy now to download the full PDF (27 pages)
Need quotation for your management?
Get a formal quotation for YD/T 1595.1-2012 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
December 28, 2012
Implementation date
March 1, 2013
Scope
YD/T 1595.1-2012 (Requirements and measurement methods of electromagnetic compatibility for 2GHz WCDMA digital cellular mobile telecommunications system - Part 1: user equipment and ancillary equipment) is available as an English-translated PDF.
YD/T 1595.1-2012 — This Part specifies the requirements of electromagnetic compatibility for user equipment and ancillary equipment of 2GHz WCDMA digital cellular mobile telecommunication system, including limits, performance criterion and measurement methods, etc. This Part applies to user equipment and ancillary equipment of 2GHz WCDMA digital cellular mobile telecommunication system.
Found what you need?
Document preview — YD/T 1595.1-2012
National Standard of the People's Republic of China
- ICS
- 01.040.33
- Classification
- M 04
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword...4
- 1 Scope...6
- 2 Normative references...6
- 3 Terms, definitions and abbreviations...7
- 4 Test Conditions...10
- 5 Performance Evaluation Methods...18
- 6 Performance criteria...19
- 7 Applicability...20
- 8 Disturbance measurement method and limited value...21
- 9 Test method and grade of immunity...27
Foreword
This is the first Part of "Requirements and Measurement Methods of Electromagnetic
Compatibility for 2GHz WCDMA Digital Cellular Mobile Telecommunication System". The
Standard includes the following parts.
Requirements and Measurement Methods of Electromagnetic Compatibility for 2GHz
WCDMA Digital Cellular Mobile Telecommunication System – Part 1.User Equipment
and Ancillary Equipment
And
Requirements and Measurement Methods of Electromagnetic Compatibility for 2GHz
WCDMA Digital Cellular Mobile Telecommunication System – Part 2.Base Station and
Ancillary Equipment
This Part replaces YD/T 1595.1-2007 "Requirements and Measurement Methods of
Electromagnetic Compatibility for 2GHz WCDMA Digital Cellular Mobile
Telecommunication System – Part 1.User Equipment and Ancillary Equipment".
Compared with YD/T 1595.1-2007, this Part has the following main changes.
a) In the normative reference documents, use YD/T 1483 to replace ITU-R SM329 and
GB/T 17626.29 to replace IEC 61000-4-29.
b) Alter the determination methods of narrow-band response.
c) In Chapter 5 of this Part, the version number of YD/T 1312.1 has been changed into
2008.
d) The highest frequency of radiation disturbance test of the ancillary equipment is
6GHz.
e) The highest frequency of radiation immunity test is 2.7GHz.
f) Change the rating and performance criterion of voltage dips and short interruptions
as well as voltage change immunity test.
g) The performance criterion of the surge transient immunity test is unified as
performance criterion B.
This Part mainly references to ETSI EN 301 489-24 "Electromagnetic Compatibility and
Wireless Spectrum, Electromagnetic Compatibility Standard of Wireless Equipment and
Business - Part 24.IMT-2000 Detailed Information of CDMA Direct Spread Spectrum
Mobile and Portable Radio and Ancillary Equipment" and YD/T 1483 "Technical
Requirement and Measurement Method of Spurious Emission of Radio Equipment". The
main technical difference between this Part and foreign standards is that the electric fast
transient pulses immunity test rating of the DC ports is different.
This Part was proposed by and shall be under the jurisdiction of China Communications
Standards Association.
Drafting organizations of this Part. China Academy of Telecommunication Research of
MIIT, HUAWEI TECHNOLOGIES CO., LTD. AND Zhongxing Telecommunication
Equipment Corporation.
1 Scope
This Part specifies the requirements of electromagnetic compatibility for user equipment
and ancillary equipment of 2GHz WCDMA digital cellular mobile telecommunication
system, including limits, performance criterion and measurement methods, etc.
This Part applies to user equipment and ancillary equipment of 2GHz WCDMA digital
cellular mobile telecommunication system.
2 Normative references
The following documents are indispensable for application of this document. For the dated
documents so quoted, only the dated versions apply to this document. For the undated
documents so quoted, the latest versions (including all modification sheets) apply to this
document.
GB 9254 Information technology equipment - Radio disturbance characteristics - Limits
and methods of measurement
GB 17625.1 Electromagnetic compatibility – Limits - Limits for harmonic current
emissions (equipment input current <=16 A per phase)
GB 17625.2 Electromagnetic compatibility (EMC) – Limits - Limitation of voltage
changes, voltage fluctuations and flicker in public low-voltage supply systems, for
equipment with rated current <=16 A per phase and not subject to conditional connection
GB/T 6113.101 Specification for radio disturbance and immunity measuring apparatus
and methods - Part 1-1.Radio disturbance and immunity measuring apparatus -
Measuring apparatus
GB/T 6113.104 Specification for radio disturbance and immunity measuring apparatus
and methods - Part 1-4.Radio disturbance and immunity measuring
apparatus-Ancillary equipment - Radiated disturbances
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purpose of this document, the following terms and definitions shall apply.
3.1.1
International mobile telecommunication-2000 (IMT-2000)
It is the third generation mobile telecommunication system, which can access fixed
telecommunication network (e.g. PSTN, ISDN, IP, etc.) business and other business
provided for mobile users via one or more radio links.
3.1.2
Universal Terrestrial Radio Access (UTRA)
It is a particular radio access network defined in 3GPP Specification.
3.1.3
User Equipment (UE)
It is an entity which can access UTRA business via one or more radio interfaces. When
accessing UTRA business, this entity can be either static or mobile in the UTRA business
area; this entity can serve one or more users at the same time.
3.1.4
Idle Mode
It is a state of user equipment, in which user equipment has been started but without RRC
connection.
3.1.9
Camped On a Cell
It means that UE completes the selection or reselection for a cell and is now in the idle
mode. UE monitors system information and paging messages.
Note. The business may be limited; PLMN (Public Land Mobile Network) may not know which cell has
been selected by UE to camp on.
3.1.10
Spurious Emissions
The disturbances on the discrete frequency except carrier frequency and the sideband
related to normal modulation, including conducted spurious emissions and radiated
spurious emissions.
3.2 Abbreviations
The following abbreviations are applied in this document.
4 Test Conditions
4.1 General Conditions
EUT shall be tested in normal testing environment which shall be recorded in the report.
If EUT has separable integral antennas, unless otherwise specified in this Part, it shall be
equipped with antennas to conduct the test the way it is normally used.
The test arrangement shall be as approximate to normal or typical actual running state as
possible.
4.2 Test Arrangement
During the test, frequency of RF signals shall be selected from appropriate UTRA absolute
radio frequency channel number (UTRA ARFCN).
4.2.3 Test Arrangement of Receiver Input Port
SS shall be placed outside the testing environment.
The frequency of useful RF input signal for providing telecommunication links shall be
selected through correct UTRA ARFCN, unless otherwise specified in other Parts of this
Standard, it is advisable to select the UTRA ARFCN corresponding to the center
frequency of the operating frequency band.
4.6 Immunity Test Conditions and Arrangement
6.4 Performance criteria C (discontinuous phenomenon)
In test, performance is allowed to have degradation, and function can be lost; EUT sender
shall not generate unconscious launch under idle mode. After test, function can be
recovered by operator. After recovery, performance is not degraded and EUT can work
normally.
7 Applicability
7.1 Disturbance measurement
Items for disturbance measurement are shown in Table 1.
8 Disturbance measurement method and limited value
8.1 Antenna's port (conducted spurious)
Measurement method of this item shall be carried out according to relevant contents of
YD/T 1483.
8.2.2 Limit value
8.2.2.1 Business mode
Limit value is shown in Table 5.
8.3 Chassis' port of auxiliary equipment
8.3.1 General conditions
Measurement shall be carried out under such mode as EUT works normally to generate
the maximum disturbance.
It shall make radiation continuous disturbance measured up to the maximum value, such
as cable passing through mobile EUT.
8.4 Telecom's port
8.4.1 Measurement method
Measurement shall be carried out according to GB 9254.
8.5 DC power input/output port
8.5.1 Measurement method
Measurement shall be carried out according to GB 9254.
When the results meet average limit value by using quasi-peak detection measurement, it
shall be considered it meets requirements of 2 limit values, and it's unnecessary to have
average value detection measurement.
frequency.
8.6 AC power input/output port
8.6.1 Measurement method
Measurement shall be carried out according to GB 9254.AMN is connected with across
current power.
9 Test method and grade of immunity
9.1 Electrostatic discharge immunity test
9.1.1 Test method and grade
Test shall be carried out according to GB/T 17626.2.
It shall meet the following requirements.
9.12 Performance criteria
Performance criteria in 6.3 of this Part are applicable to this term.
9.2 Radiation disturbance immunity test (800MHz ~ 2.7GHz)
9.5 Conducted disturbance immunity test of radiofrequency field sensitivity
9.5.1 Test method and grade
When the connection cable for AC power port/signal/telecom/control port and DC power
port of fixed, on-board and auxiliary equipment exceeds 3 meters, this test item shall be
carried out.
9.6 Power frequency magnetic field immunity test
9.6.1 Test method and grade
This test item is only applicable to EUT with device sensitive to magnetic field. The test
method is shown in GB/T 17626.8.
Test grade is 3A/m.
9.7 Immunity test of voltage dips, short interruption and voltage change
9.7.1 Test method and grade
9.7.2 Performance criteria
9.7.2.1 Across current power supply performance criteria
For voltage dips that power supply voltage drops 100% and time duration is 10ms; power
supply voltage drops 100% and time duration is 20ms; power supply voltage drops 30%
and time duration is 500ms, performance criteria B in 6.3 of this Part are applicable to this
term.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 17625.1Electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions(equipment input current <=16 A per phase)
- GB 17625.2[GB/T 17625.2-2007] Electromagnetic compatibility (EMC) -- Limits -- Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <=16 A per phase and not subject to conditional conn
- GB/T 6113.101Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
- GB/T 6113.104Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
GB 9254
How to Download YD/T 1595.1-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 17625.1-2022 — Electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions(equipment input current <=16 A per phase)
GB 17625.2-2007 — [GB/T 17625.2-2007] Electromagnetic compatibility (EMC) -- Limits -- Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <=16 A per phase and not subject to conditional conn
GB/T 6113.101-2021 — Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
Secure payment via Stripe