YD/T 1356-2005The specification for user power feeding of ISDA basic access U interface on the switch (English PDF)
交换机综合业务数字网(ISDN)基本接入速率“U”接口对用户供电要求
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for YD/T 1356-2005 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
May 11, 2005
Implementation date
November 1, 2005
Scope
YD/T 1356-2005 is the English-translated version of 交换机综合业务数字网(ISDN)基本接入速率“U”接口对用户供电要求.
YD/T 1356-2005 is the Chinese standard "The specification for user power feeding of ISDA basic access U interface on the switch".
This standard specifies the function with ISDN switch LT "U" interface to the user side of the power supply configuration, supply power, output voltage, output current, the protection threshold and the associated detection methods.
This standard applies to ISDN function switches and their associated NT1, NT1 + other network terminal equipment, ISDN terminal equipment and the need for the network side (CO) Far-powered basic rate digital transmission systems.
This standard can also be used as an ISDN metallic local line power requirements of digital transmission systems away basis. This standard specifies the parameters is based on the power supply line of the user's system, but does not intervene in the discharge during the application of regenerative repeater mode.
For the powered device or system for self-switch LT "U" interface to obtain the distribution of power usage values ??not specified in this standard. Issued on 2005-05-11, in force from 2005-11-01.
Found what you need?
Document preview — YD/T 1356-2005
National Standard of the People's Republic of China
- ICS
- 40.30
- Classification
- M38
Contents
- [Preview only]
- 1 Scope
- 2 Normative references
- 3 Abbreviations
- 3.1 Terms and definitions
- 4 General
- 4.1 Test environment
- 4.2 UE Information
- 4.3 Test Implementation
- 5 Requirements
1 Foreword
YD/T 1356-2005 was issued by Ministry of Industry and Information Technology on 11 May 2005 and has been in force since 1 November 2005.
The YD/T prefix marks a recommended standard. It is not law in itself: it becomes binding when a contract names it, when a regulation or a mandatory standard refers to it, or when a producer declares conformity with it.
The document runs to 11 pages in English translation.
2 Scope Preview
This standard specifies the function with ISDN switch LT "U" interface to the user side of the power supply configuration, supply power, output voltage, output current, the protection threshold and the associated detection methods. This standard applies to ISDN function switches and their associated NT1, NT1 + other network terminal equipment, ISDN terminal equipment and the need for the network side (CO) Far-powered basic rate digital transmission systems. This standard can also be used as an ISDN metallic local line power requirements of digital transmission systems away basis. This standard specifies the parameters is based on the power supply line of the user's system, but does not intervene in the discharge during the application of regenerative repeater mode. For the powered device or system for self-switch LT "U" interface to obtain the distribution of power usage values ??not specified in this standard.
YD/T 1356-2005 is filed under Chinese Standard Classification M38, in the field of telecommunications and broadcasting.
This catalogue holds 2,288 other YD/T standards without an ICS number.
In this catalogue, YD/T standards carry edition years from 1982 to 2026.
3 About this standard
Sector: Telecommunication Industry Standard (Recommended)
Issued by: Ministry of Industry and Information Technology
English translation: about 11 pages (approximate)
Chinese original: about 17,130 characters
4 Related standards
Standards on related subjects:
GB/T 12572-2008 — Universal requirements and measurement methods of parameters for radio transmitting equipment
YD 1268.1-2003 — [YD/T 1268.1-2003] The safety specification and test method for lithium batteries
YD 1268.2-2003 — [YD/T 1268.2-2003] The safety specification and test method for lithium battery charger
YD/T 6165-2024 — IP source address verification technology testing method
YD/T 2253-2011 — Communication security specification of soft switch-based network
5 Classification and status
International classification (ICS): 40.30
Chinese Standard Classification (CCS): M 38
Prefix YD/T: recommended standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download YD/T 1356-2005
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YD/T 1114-2026 — Halogen-free flame retardant optical fibre cable
YD/T 1181.1-2026 — Characteristics of non-metal reinforcement used for optical fiber cables - Part 1: Glass fiber reinforced plastic rods
YD/T 1181.3-2026 — Characteristics of non-metal reinforcement for optical fiber cables - Part 3: aramid fiber reinforced plastic rods
YD/T 1356-2005
$195.00