YC/T 169.10-2009Determination of physical and chemical characteristics of tow for cigarette. Part 10: Residual acetone content (English PDF)
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for YC/T 169.10-2009 in 30 minutes.
Issued by
State Tobacco Monopoly Administration
Level / Type
National · Recommended
Issue date
March 30, 2009
Implementation date
May 1, 2009
Scope
YC/T 169.10-2009 (Determination of physical and chemical characteristics of tow for cigarette. Part 10: Residual acetone content) is available as an English-translated PDF.
YC/T 169.10-2009 — YC/T in this part 169 specifies the method for measuring the smoke residual acetone content tow. This section applies to tobacco cellulose diacetate tow.
Principle 2 The tow sample into the extraction agent containing the internal standard in the extract, acetone extract Determination by gas chromatography to calculate the tow Content of acetone, internal standard.
Found what you need?
Document preview — YC/T 169.10-2009
National Standard of the People's Republic of China
- ICS
- 65.160
- Classification
- X 85
- Replacing
- YC/T 169.10-2002
Issued by: State Tobacco Monopoly Administration
Contents
- Foreword
- 1 Scope
- 3 Reagents
- 4 Equipment
- 5 Sampling
- 6 Step, Analysis
- 6.1 Extraction
Foreword
YC/T 169 "cigarette tow physical and chemical properties of determination" is divided into 12 parts.
--- Part 1. tow linear density;
--- Part 2. Single yarn density;
--- Part 3. number of crimps;
--- Part 4. tow crimp index and the crimp tow elastic recovery;
--- Part 5. breaking strength;
--- Part 6. cross-sectional shape;
--- Part 7. Regain;
--- Part 8. moisture content;
--- Part 9. oil content;
--- Part 10. residual acetone content;
--- Part 11. Titanium dioxide content;
--- Part 12. Packaging and appearance.
This section YC/T 169 Part 10.
This Part replaces YC/T 169.10-2002 "tow for cigarette was measured series of standards - Part 10. residual acetone content." this section compared with YC/T 169.10-2002 main changes are as follows.
--- By the name of this section. Change "series of standards for cigarette tow Part 10 Determination of the residual acetone content" to "cigarette tow physicochemical Part 10 Determination of properties. residual acetone content ";
--- Cancel the normative references;
--- Modify the measurement principle, modified by the external calibration standard curve as internal standard curve method;
--- Increased ethanol as internal standard in the reagent;
--- Modify the sample;
--- Modify the formula in calculation and shows the results in;
--- Measurement report adds two things. "the provisions of this part of the step of determining the difference" and "observed abnormal test phenomenon";
--- Added Appendix A.
Appendix A of this section is an informative annex.
This part by the State Tobacco Monopoly Bureau.
This part of the National Standardization Technical Committee of tobacco smokable material Technical Committee (SAC/TC144/SC8) centralized.
This section drafted by. China National Tobacco Quality Supervision and Inspection Center, Kunming Cellulose Fiber Co., Ltd., Nantong Cellulose Fibers Co., Ltd., Zhuhai Sea Acetate Limited.
1 Scope
YC/T in this part 169 specifies the method for measuring the smoke residual acetone content tow.
This section applies to tobacco cellulose diacetate tow.
Principle 2
The tow sample into the extraction agent containing the internal standard in the extract, acetone extract Determination by gas chromatography to calculate the tow Content of acetone, internal standard.
3 Reagents
Except where noted, you should use analytical grade reagents.
3.1 Carrier gas. helium or nitrogen gas (99.99% purity).
3.2 Standard substance. acetone.
3.3 distilled water.
3.4 Internal standard. ethanol (purity above 99%).
3.5 Extraction solvent. distilled water containing the appropriate concentration of internal standard (3.4) of (3.3), the dosage of 0.1mL/L.
3.6 Standard stock solution (about 0.07g/mL). Pipette 9mL acetone (3.2) in 100mL flask with extracting agent (3.5) constant volume, shake Dynamic mixing. Specific concentration calculated with acetone purity, density.
3.7 Working standard solution. Pipette respectively 0.01mL, 0.05mL, 0.1mL, 0.2mL, 0.3mL and 0.5mL of standard stock solution (3.6) in six 200mL flask with extracting agent (3.5) to volume, shake mix. Yield acetone standard solution of different concentrations, the concentration range should cover the expected concentration of acetone was detected in the sample.
4 Equipment
Common laboratory apparatus and the following items.
4.1 Gas chromatograph equipped with a flame ionization detector (FID).
4.2 Analysis of balance. a sense of the amount of 0.01g.
4.3 oscillator.
4.4 flask. 500mL.
5 Sampling
Within randomly selected sample of about 30g placed 250mL glass container, after sealing fast as samples to be tested. In order to avoid sample Pollution, in any case, should not be directly used wax, paraffin wax or paper seal glue on the cork.
Note. The test sample should be required at the time of sample extraction alone.
6 Step, Analysis
6.1 Extraction
Measure 200mL extraction solvent (3.5) in 500mL flask (4.4), and accurately weighed 7.0g (accurate to 0.01g) containing the sample is placed
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download YC/T 169.10-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YC/T 169.1-2009 — Determination of physical and chemical characteristics of tow for cigarette. Part 1: Total line density
YC/T 169.1-2002 — Determination of physical and chemical characteristics of tow for cigarette. Part 1: Total line density
YC/T 169.10-2002 — Determination of physical and chemical characteristics of tow for cigarette. Part 10: Residual acetone content
Secure payment via Stripe
Payments accepted
YC/T 169.10-2009
$144.00