WS 392-2012Clinical application of ventilator (English PDF)
呼吸机临床应用
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for WS 392-2012 in 30 minutes.
Issued by
National Health and Family Planning Commission of the People's Republic of China
Level / Type
National · Mandatory
Issue date
January 1, 2012
Implementation date
April 1, 2013
Scope
WS 392-2012 is the English-translated version of 呼吸机临床应用.
WS 392-2012 - This standard specifies the basic requirements of the use of ventilators and units, clinical application process, monitoring indicators, scope of application of breathing machine, breathing Machine classification and use, care principles, ventilator treatment of sedation, analgesics and muscle relaxants and application of norms related to ventilator and so on.
This standard applies to all levels of medical institutions across the country medical staff on the clinical application of ventilator.
Found what you need?
Document preview — WS 392-2012
National Standard of the People's Republic of China
- ICS
- 11.020
- Classification
- C05
Issued by: National Health and Family Planning Commission of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Ventilator users basic requirements
- 5 Ventilator use the basic requirements of the unit
- 6 Ventilator use process
- 7 Ventilator monitoring indicators during use
- 8 Ventilator scope of application
- 9 Ventilator classification and clinical application of methods
- 10 Ventilator during the treatment of care
- 11 Ventilator treatment of sedation, analgesics and muscle relaxants
- Ventilator-related complications
- Appendix A (informative) Mechanical ventilation weaning evaluation index
- Appendix B (Informative) Non-invasive positive pressure ventilation weaning procedures
- Appendix C (informative) ventilator cleaning and disinfection
- References
Foreword
Chapter 4 of this standard, Chapter 5, Chapter 6, Chapter 7 is mandatory, the rest are recommended terms.
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed by the Ministry of Health Medical Services Standards Committee.
This standard was drafted. Huazhong University of Science and Technology Tongji Medical College Affiliated Union Hospital, Xiangya Hospital of Central South University, Fourth Military Medical University Affiliated Xijing Hospital, Affiliated Renji Hospital of Shanghai Jiaotong University, People's Hospital of Wuhan University, First Affiliated Hospital of Chongqing Medical University, Zhejiang Medical University Run Run Shaw Hospital Affiliated to Medical College, First Affiliated Hospital of Nanjing Medical University.
1 Scope
This standard specifies the basic requirements of the use of ventilators and units, clinical application process, monitoring indicators, scope of application of breathing machine, breathing Machine classification and use, care principles, ventilator treatment of sedation, analgesics and muscle relaxants and application of norms related to ventilator and so on.
This standard applies to all levels of medical institutions across the country medical staff on the clinical application of ventilator.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 9706.28 Medical electrical equipment - Part 2. Ventilator safety requirements for the treatment of ventilator WS 310 hospital disinfection supply center
3 Terms and definitions
The following terms and definitions apply to this document.
Ventilator Life support devices that improve respiratory function, reduce respiratory effort, and save heart reserve.
Mechanical ventilation Use of a ventilator to restore effective ventilation and improve oxygenation in patients with impaired natural ventilation and/or oxygenation.
Non-invasive positive pressure ventilation for non-invasive positive pressure ventventilation, NPPV or NIPPV Via nasal mask or mask and other ways to connect the patient and ventilator mechanical ventilation.
Artificial airway Transnasal, oral or tracheostomy and other means into the catheter to establish a temporary gas channel.
Volumetric ventilation or volume controlled ventilation volume-controledventilation, VCV the ventilator ventilates with a preset ventilation capacity.
Fixed pressure ventilation or pressure pre-set ventilation pressure-controledventilation, PCV Ventilator ventilates with preset airway pressure.
Control ventilation controledventilation; CV Breathing machine completely replace the patient's spontaneous breathing, providing all the work of breathing.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
How to Download WS 392-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.28-2006 — Medical electrical equipment - Part 2: Particular requirements for the safety of lung ventilators - Critical care ventilators
WS 310.1-2009 — Central sterile supply department (CSSD). Part Ⅰ: management standard
WS 310.1-2016 — Central sterile supply department(CSSD). Part 1: Management standard