T/CSAE 43-2015 is the English-translated version of 电动汽车CAN总线测试规范.

T/CSAE 43-2015 — This specification specifies the basic method for high-speed CAN bus testing of pure electric passenger cars. The extended program and plug-in passenger cars are used as reference.

This specification applies to CAN bus networks with baud rates between 125 Kbps and 1 Mbps. This specification does not include EMC and EMI testing for the CAN bus.

Found what you need?

Document preview — T/CSAE 43-2015

National Standard of the People's Republic of China

ICS
43.120
Classification
T 09

Issued by: China Society of Automotive Engineers

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Definitions and acronyms
  • 4 Test preparation
  • 4.1 Testing Resources
  • 5 Test requirements and methods
  • 5.1 Physical layer

Foreword

"Electric Vehicle CAN Bus Test Specification" explains the test of the physical layer, data link layer and application layer of CAN bus of electric vehicle in order to effectively verify and confirm the node and bus system of the electric vehicle CAN bus system.

This specification was proposed by the Electric Vehicle Industry Technology Innovation Alliance.

This specification is under the jurisdiction of the China Automotive Engineering Society.

This specification was drafted by Tianjin Qingyuan Electric Vehicle Co., Ltd. and Beijing University of Aeronautics and Astronautics.

1 Scope

This specification specifies the basic method for high-speed CAN bus testing of pure electric passenger cars. The extended program and plug-in passenger cars are used as reference.

This specification applies to CAN bus networks with baud rates between 125 Kbps and 1 Mbps.

This specification does not include EMC and EMI testing for the CAN bus.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this edition.

file. For undated references, the latest edition (including all amendments) applies to this document.

ISO 11898-2003 Road vehicles-Controller area network(CAN) ISO 16845-2004 Road vehicles-Controller area network (CAN) -- Conformance test plan ISO 7637-2008 Road vehicles-Electrical disturbances from conduction and coupling SAE J1939-Recommended Practice for a Serial Control and Communications Vehicle Network

3 Definitions and acronyms

The following definitions and acronyms apply to this document.

The response is used to verify that the required operation has been understood and executed.

The address is used to define the 8-bit field of the message source (and destination, where applicable).

Arbitration A single or multiple ECUs resolve the bus collision process when accessing a shared network.

The CAN data frame establishes the ordered bit field required for the CAN frame. It is used to transmit information, starting with SOF and ending with EOF.

The device has one or more components of the ECU and network interface.

ECU An integrated computer-controlled electronic device that transmits and receives messages.

The extended frame uses a 29-bit identifier for the CAN data frame, which is defined in the CAN 2.0 rules.

A complete message consisting of a series of data bits. A frame is divided into multiple fields, each of which contains a type of predefined data.

See CAN data frame.

A "message" of a message is equivalent to one or more "CAN data frames" having the same number of parameter sets. For example, one has a single A parameter number of packets may be sent with multiple CAN data frames.

Hardware connection between the node ECU and the physical medium. A node can declare multiple addresses in the network.

DUT device under test.

Figure 0 Test the symbols used in the build diagram

4 Test preparation

4.1 Testing Resources

4.1.1 Verification

Test equipment and instruments need to be in good working order and need to be labeled with valid verification labels.

4.1.2 Alternative equipment

Alternative laboratory facilities and equipment may be used, but must be consistent with the physical definition of all specified measurement variables in this specification.

5 Test requirements and methods

5.1 Physical layer

This chapter details the verification test of the physical layer of the high-speed CAN interface, which is only applicable to the two-wire high-speed CAN bus device.

5.1.1 CAN bus output voltage level test

5.1.1.1 Implicit output voltage level

Test range. measure the CAN bus output voltage level in the recessive state and check if they meet the physical layer of the car LAN.

Claim.

Test conditions. See Table 1. Apply test circuit according to Figure 1.

Test method. Measure the absolute value of the differential voltage between the CANH and CANL lines. In addition, the bus common mode voltage VCM is also measured.

Vdiff = VCAN_H – VCAN_L VCM = 0.5 * (VCAN_H VCAN_L) Detection criteria. see Table 1

Table 1 ECU recessive output voltage

Recessive state

Parameter symbol

condition

Minimum rated maximum Output bus voltage VCAN_H

2.5 V 7.0 V no load

Output bus voltage VCAN_L -2.0 V 2.5 V no load Differential output voltage Vdiff -120mV 0 12mV See Table 2 (Test Example 1) Note. A secondary termination resistor can be added when testing that the CAN line is too long or there are too many CAN nodes causing distortion in the CAN signal.

Table 2 Test configuration based on termination resistance

Note 1. If the device under test does not have a terminating resistor installed, you can add a terminal network to the dotted rectangles 1 and 2.

Note 2. If the device under test already contains a 120ohm termination resistor, you can add a terminal network to the dotted rectangle 1.

Note 3. If the device under test contains a central termination resistor (60 ohm), no additional terminal network can be added.

Note 4. RX is used to simulate 4 additional CAN communication nodes with a secondary termination resistance of 1200ohm.

Note 5. Table 2 lists the applicable resistance values.

Figure 1 High-speed CAN test setup

5.1.1.2 Dominant output voltage level

Test range. measure the CAN bus output voltage level in the recessive state and check if they meet the physical layer of the car LAN.

Claim.

Test conditions. See Table 1. Apply test circuit according to Figure 1.

Test method. Measure the absolute value of the differential voltage between the CANH and CANL lines. In addition, the bus common mode voltage VCM is also measured.

Vdiff = VCAN_H – VCAN_L VCM = 0.5 * (VCAN_H VCAN_L) Detection criteria. see Table 3 Device under test terminal resistance terminal network 1 terminal network 2 Rx Test Method 1 Test Method 2 no terminal connection no connection 180ohm Central terminal (60ohm) No connection, no connection, no connection, 180ohm Fixed terminal (120ohm) connection no connection no connection 180ohm Secondary terminal (1200ohm) connection no connection 211ohm CAN-H CAN-L

Table 3 dominant output voltage

Note 1. If the device under test (device under test) does not have a terminating resistor installed, you can add a terminal network to the dotted rectangles 1 and 2.

Note 2. If the device under test already contains a 120ohm termination resistor, you can add a terminal network to the dotted rectangle 1.

Note 3. If the device under test contains a central termination resistor (60ohm), no additional terminal network can be added.

Note 4. RX is used to simulate 4 additional CAN communication nodes with a secondary termination resistance of 1200ohm.

Note 5. Table 2 lists the applicable resistance values.

5.1.2 Implicit input threshold

Test range. Measure the implicit input threshold of the device under test.

Test conditions. The test circuit shown in Figure 2 was used.

If the device under test is equipped with a standard terminating resistor, RTest = 120ohm.

If the device under test does not have a terminating resistor, RTest = 60ohm.

Test method. set the value of current I so that the upper threshold VDIFF = 0.5V, then set the voltage U, respectively set to

a) V=-2 V, b) V = 6.5V.

Detection criteria. In the case of two voltage tests, the device under test does not allow the transmission of the frame to be stopped.

Figure 2 recessive input threshold test circuit

5.1.3 Explicit input threshold

Test range. Measure the dominant input threshold of the device under test.

Test conditions. Use the application test circuit as shown in Figure 3.

If the device under test is equipped with a standard termination resistor, RTest = 120ohm.

If the device under test does not have a terminating resistor, RTest = 60 ohm.

Test method. set the value of current I so that the lower threshold VDIFF=0.5V to 0.9V, the step length is 0.1V, and then set the voltage U to satisfy

a) V = -2V, b) V = 6.1V.

Dominant state

Parameter symbol

condition

Minimum rated maximum Output bus voltage VCAN_H

3.5 V 7V no load

Output bus voltage VCAN_L -2.0V 1.5 V no load Differential output voltage Vdiff 1.2V 2.0V 3.0V See Table 2 (Test Example 1) Detection criteria. In both cases, the device under test should stop transmission of its frame when the dominant input threshold reaches 0.9V.

Note. When the input threshold is 0.5V, the device under test can still send a dominant bit.

Figure 3 explicit input threshold test circuit

5.1.4 Equipment resistance
5.1.4.1 Internal resistance of CANH and CANL

Test range 1. Measure the internal resistance of CANH and CANL.

Test conditions. Use the test circuit as shown in Figure 4. If the device under test is equipped with an internal termination resistor, CANH and CANL Short circuit. RTest = 5kohm.

Note. All I/O, such as external sensors, should be connected.

Test method. Measure V and calculate Rin using the formula below.

Note. According to 5.1.1.1VCAN_L, H is the received output voltage.

If the device under test is equipped with an internal termination resistor, CANH and CANL need to be shorted. The measured Rin value in this case contains Rin_H and Rin_L, Rin are calculated as follows.

Note. VCAN is the output voltage received by 5.1.1.1. Rin_CAN_H and Rin_CAN_L are measured at U=-2V and U=-7V, respectively.

Detection criteria. see Table 4

Table 4 Test criteria

Parameter minimum rated maximum condition Rin CAN_H 5 kohm - 50 kohm no load Rin CAN_L 5 kohm - 50 kohm no load delta Rin_diff 0 ohm - 3% no load Test range 2. When the connection of the power supply voltage is interrupted, such as when the fuse is blown, it should be in CANH and CANL with the power supply or Connect a high resistance to the ground to prevent damage to the ECU.

Test conditions. No peripheral devices are connected. According to Figure 4, the test circuit is applied. If the device under test is equipped with an internal termination resistor, Then CANH and CANL should be shorted. Disconnect the device under test from the power supply line.

Test method. Measure V and calculate Rin using the formula below.

If the device under test is equipped with an internal termination resistor, CANH and CANL should be shorted. If the measured Rin value includes Rin_H and Rin_L, then Rin is calculated using the formula below.

Rin_CAN_H and Rin_CAN_L are measured when U = -2 V and U = 7 V, respectively.

Detection criteria. Rin CAN_H, L >= 5 kohm.

Figure 4 Measurement of built-in resistors

Test range 3. If the ground connection of the ECU is disconnected, CANH and CANL should be connected to a high resistance to ground to prevent damage to the ECU.

Test conditions. Set VBATT to 14.5V. Disconnect the ground wire of the device under test. The test circuit of Figure 5 is used.

Note. All I/O such as external sensors should be connected.

Test method. Measure the output leakage current Ileak between the device under test CANH and the ground and CANL ground. Calculate Rin_CAN_H using the formula below and Rin_CAN_L.

Detection criteria. Rin CAN_H, L >= 5 kohm

Figure 5 Recording measurement internal resistance

5.1.4.2 Internal Differential Resistor

Test range. Measure the internal differential resistance of the device under test.

Test conditions. Apply test circuit U = 5 V according to Figure 6.

If the device under test is equipped with a 120ohm termination resistor, RTest=120ohm.

If the device under test is equipped with a central terminal network, RTest = 60ohm.

If the device under test is equipped with a secondary terminal network, RTest = 1200 ohm.

If the device under test does not have a terminating resistor, RTest = 10Kohm.

Note. If a terminating resistor is integrated in the ECU, then this measurement is more or less a measure of the terminating resistance.

Test method. measure V and calculate Rdiff using the following formula Note. According to 5.1.1.1, Vdiff is a recessive difference to separate the voltage.

Detection criteria. see Table 5

Table 5 Detection criteria for internal differential resistors

Figure 6 internal differential resistance measurement

5.1.5 Test Equipment Input Capacitance

Test range. Measure the input capacitance of the device under test.

Test conditions. The test circuit is applied according to Figures 7 and 8 (Rtest is a non-inductive resistor and the diode uses a Schottky fast recovery diode).

Test method. Measure tau Figure 7 by the measurement method shown in Figure 7, and calculate CFigure7 using the following formula.

Parameter minimum rated maximum condition Rdiff 10 kohm - 100 kohm device under test without bus terminating resistor Rdiff 116ohm 120 128ohm device under test with inherent bus termination resistance Rdiff 58ohm 60 64ohm device under test with central bus terminating resistor Rdiff 1091ohm 1200 1253ohm Device under test with secondary bus terminating resistor tau Figure 8 is measured by the measurement method shown in Fig. 8, and CFigure 8 is calculated by the following formula.

Note. tau is the fall time when VCAN reaches 37%.

Detection criteria. 40 pF <= Cin CAN_H <= 150 pF 40 pF <= Cin CAN_L <= 150 pF 0 pF <= Cdiff <= 90 pF

Figure 7 tauFigure7 measurement

Figure 8 tauFigure8 measurement

Figure 9 tau definition

5.1.6 Minimum and maximum supply levels for bus communication

Test range. Determine the minimum and maximum voltage thresholds for normal bus communication.

Test conditions. Establish a physical network consisting of the device under test and the test tool. Test tool can simulate all nodes, this these nodes are necessary for the bus communication of the device under test to be normal.

Test method. The power supply voltage of the device under test is set to 12V. Reduce the power of the device under test by reducing the speed by 0.1V per minute.

Source voltage. Check the bus communication and measure the lowest supply voltage that guarantees the normal operation of the bus, ie there is no error frame on the bus.

No damage or no delay in message transmission. After the communication is stopped, increase the power supply voltage by 0.1V per minute, and measure the voltage recovered by the communication.

value. Then set the supply voltage to 0V (t > 10 s). Then directly set the power supply voltage to 6.5 V to measure the bus communication of the device under test.

The time of recovery, such as successfully receiving or sending a message. In order to measure the maximum supply voltage that guarantees the CAN communication function, the supply voltage is gradually stepped Increase to a maximum of 26.5V.

Detection criteria. For devices that support communication within the extended supply voltage range. when the supply voltage is reduced to 6V, the device under test Communication needs to be guaranteed to be error free. After the supply voltage rises to 6V, the device under test should resume bus communication within 300 milliseconds.

Unless otherwise specified, the device under test shall support normal communication at a supply voltage of 16-18V for 1 hour.

For devices that do not require support communication within the extended supply voltage range. the device under test needs to be supported when the supply voltage is at least 9V or higher.

Hold the newsletter. After the supply voltage rises to 9V, the device under test should resume bus communication within 300 milliseconds.

5.1.7 Characteristics during voltage drop

Test range. Check the characteristics of the device under test when the voltage drops.

Test conditions. Establish a physical network consisting of the device under test and the test tool. Test tool can simulate all nodes, this these nodes are necessary for the bus communication of the device under test to be normal.

Test Method. Apply Test No. 4 (Severe Pulse IV) test tool simulation in ISO 7637-2 to the power line of the device under test.

The other terminal device responds normally to the packet of the device under test.

Detection criteria. for devices that support communication during vehicle start-up. when the supply voltage is reduced to 6V (starting with a low-voltage system) Motivation), the communication of the device under test needs to ensure no error; the device that does not support communication during vehicle startup, the power supply voltage rises up to 6.5V After that, the device under test should resume bus communication within 300 milliseconds.

Note. For ECUs, CAN communication should be supported during voltage dips, Vresume = 6 V.

In addition, unless otherwise specified, the device under test shall support normal communication within the supply voltage of 16-18V for 1 hour.

Communication in the range of 1h16-18V, 1min18-26.5V (starting condition).

For devices that do not support communication during vehicle start-up. The device under test should not cause any error conditions on the bus, ie, it has been started.

There are no fault frames before and after the process. When the supply voltage rises to no more than 9V, the device under test should resume bus communication within 300 milliseconds.

5.1.8 Signal rise/fall time

Test range. measuring the transition time of CAN signals from recessive to dominant and from dominant to recessive Test conditions. Apply the test circuit according to Figure 10 (including capacitance, see Table 6 for values). In order to minimize the need for testing in terms of measurement for the effect of the setting, all wire lengths should be less than 1.0 m. The rise/fall time is measured under maximum and minimum physical load conditions.

Test cases 1 and 2 are shown in Table 2.

Test method. Measure the rise/fall time of the CAN bus signal of the device under test from 20% to 80% of Vdiff (=CANH-CANL).

Rise time. The transition time from recessive to dominant.

Fall time. The transition time from dominant to recessive.

Perform at least 1000 measurements on each side to determine the minimum and maximum values of the rise/fall time.

Table 6 High-speed CAN capacitive load

Capacitor minimum load maximum load C1 100pF 4.7nF C2 100pF 4.7nF C3 0pF 3.3nF Detection criteria. The number of measurements must be measured within the limits of Table 7.

Table 7 Range of rise/fall limits

condition

Rising limit range

Minimum, maximum, minimum, maximum Minimum load 15ns 150ns 15ns 300ns Maximum load 15ns 1300ns 15ns 1300ns

Note 1. If there is no terminal network in the device under test, you can add a terminal network in the dotted boxes 1 and 2.

Note 2. If the device under test contains a 120ohm termination resistor, you can add a terminal network in the dotted box 1.

Note 3. If the device under test contains a central termination resistor (60 ohm), no additional terminal network can be added.

Note 4. RX (1200 ohm) simulates two additional nodes of the secondary terminal. Table 2 lists the applicable resistance values.

Note 5. C1, C2, and C3 are additional capacitors to simulate capacitive loads caused by other nodes and harnesses.

Figure 10 Test setup for rise/fall time measurement

Figure 11 Definition of rise and fall times

5.1.9 Characteristics of the signal (symmetric load)

Test range. Detect the bilateral symmetry of the CAN bus signal under different physical load conditions.

Test conditions. Test circuit 1 and 2 in Table 2 were performed using the test circuit of FIG. The length of all lines should be less than 1.0m, should Below the maximum and minimum values of the physical load conditions to the test signal. See Table 6. Channel 1 of the oscilloscope is connected to CANH, channel 2 and CANL connection. The third channel should show the sum of channel 1 and channel 2. In order to reduce the asymmetry caused by the test configuration, the C1 and C2 tolerances should be ±1% range.

Test Method. Under the given conditions, use an oscilloscope to measure the dominant signal waveform and refer to the chart in the test report. Oscillating the platform should display CANH, CANL, CANH CANL and RxD-line (where possible).

Test criteria. The engineer responsible for testing should evaluate all asymmetry characteristics or oscillations recorded.

During the first 50% of the bit period, the bus output level should be the DC output at the end of the bit (the voltage at the end bit time is 75% sampled) Values range from 81% to 150%.

During the last 50% of the bit period, the bus output level should be the DC output at the end of the bit (the end bit time is 75% sampled) the pressure value is in the range of 95% to 105%.

The sum of CANH and CANL should be within the following limits.

The sum of the sum of CANH and CANL should be within 95%-105% of its average voltage level.

Figure 12 Example of a symmetric CAN bus signal

5.1.10 Bit time

General range. Determine the accuracy of sending and receiving messages at bit times.

5.1.10.1 CAN bus bit time tolerance Test range. Determine the tolerance of the CAN bit time of the device under test.

Test conditions. Test the circuit according to Figure 10. Follow the test cases 1, 2 in Table 2. All harness lengths should be less than 1.0m.

The bit time test should be performed between the maximum and minimum physical load conditions. According to Table 6, all combinations are given separately on the device.

Test the highest and lowest temperatures.

Test conditions. Test the bit time of the device under test with an oscilloscope. The device under test triggers a message (for example. general status letter) Time), measuring time between the recessive to dominant...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.

Referenced standards

Normative references

ISO 11898-2003 · ISO 16845-2004 · ISO 7637-2008

How to Download T/CSAE 43-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
25 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

T/CSAE 43-2015

$495.00