Scope

T/CSAE 41-2015 is the English-translated version of 电动汽车整车控制器测试评价规范.

T/CSAE 41-2015 — This standard only specifies the test and evaluation method for the performance and reliability of the hardware controller of the electric passenger vehicle.

The purpose of this standard is to serve as the basis for the evaluation of the vehicle controller within the company. This specification applies to the evaluation of vehicle controllers based on electric vehicles and hybrid vehicles.

Found what you need?

Document preview — T/CSAE 41-2015

National Standard of the People's Republic of China

ICS
43.040.01
Classification
T 47

Issued by: China Society of Automotive Engineers

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and acronyms
  • 3.1 Vehicle controller
  • 3.2 Electromagnetic compatibility
  • 3.3 Electromagnetic disturbance
  • 3.5 Electromagnetic environment
  • 3.6 Immunity limit
  • 3.7 Reference antenna
  • 3.8 Shielding room
  • 3.9 Semi-anechoic chamber
  • 3.10 Outer casing
  • 3.11 Degree of protection
  • 3.12 IP code
  • 4 Functional status classification
  • 4.1 Class A
  • 4.2 Class B
  • 4.3 Class C
  • 4.4 Class D
  • 4.4 Class E
  • 5 Specific test items
  • 5.1 Test sequence
  • 5.2 General test conditions
  • 6 Voltage interruption test
  • 7 Short circuit test short circuit test
  • 13 Vibration resistance test
  • 14 Dustproof and waterproof performance test
  • 15 Salt spray resistance test
  • 16 Moisture and heat cycle performance test
  • 19 Radiated immunity performance test
  • 20 High current injection test
  • 21 Power transient immunity test
  • 22 Electrostatic discharge test

Foreword

"Electric Vehicle Vehicle Controller Test Evaluation Specification" introduces the application conditions of the electric vehicle controller and specifies the basic norms of test evaluation, in order to provide a basis for enterprises to develop electric vehicle controllers, and also beneficial to China's electric vehicles the industry forms a unified diagnostic and maintenance standard.

-- Part 1. Scope of application of the document;

-- Part 2. Normative references;

-- Part 3. Definitions and terminology;

-- Part 4. Classification of system function status;

-- Part 5. Specific test specifications.

This specification was proposed by the Electric Vehicle Industry Technology Innovation Alliance.

This specification is under the jurisdiction of the China Automotive Engineering Society.

This document was drafted. Tianjin Qingyuan Electric Vehicle Co., Ltd., Beijing University of Aeronautics and Astronautics

1 Scope

This standard only specifies the test and evaluation method for the performance and reliability of the hardware controller of the electric passenger vehicle.

The purpose of this standard is to serve as the basis for the evaluation of the vehicle controller within the company.

This specification applies to the evaluation of vehicle controllers based on electric vehicles and hybrid vehicles.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies.

This document. For undated references, the latest edition (including all amendments) applies to this document.

QC/T 413-2002 Basic technical conditions for automotive electrical equipment GB/T 17619 Electromagnetic radiation immunity limits and measuring methods for motor vehicle electrical and electronic components CISPR 25.2008 Vehicles, boats and internal combustion engines – Radio disturbance characteristics –Limits and methods of measurement for the protection of on-board receivers ISO 10605.:2008 Road vehicles - Test methods for electrical disturbances from electrostatic Discharge ISO 7637-2:2011 Road vehicles - Electrical disturbances from conduction and coupling - Part 2.

Electrical transient sales along supply lines only ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband Radiated electromagnetic energy - Part 2. Absorber-lined shielded enclosure ISO 11452-4:2011 Road vehicles - Component test methods for electrical disturbances from Narrowband radiated electromagnetic energy - Part 4. Bulk current injection (BCI) ISO 16750.1 Road vehicle-Environmental conditions and testing for electrical and electronic Equipment Part 1. General ISO 16750.2 Road vehicle-Environmental conditions and testing for electrical and electronic Equipment Part 2. Electrical loads GB/T 2423.1-2008 Environmental testing of electrical and electronic products - Part 2. Test methods Test A. Low temperature GB/T 2423.2-2008 Environmental testing of electrical and electronic products - Part 2. Test methods Test B. High temperature GB/T 2423.10-2008 Environmental testing of electric and electronic products - Part 2. Test method test F c. Vibration (sinusoidal) GB/T 2423-17-2008 Basic environmental test procedures for electrical and electronic products test Ka. salt spray test method GB/T 2423-22-2012 Basic environmental test procedures for electric and electronic products - Test N. Test method for temperature change GB/T 2423-34-2012 Environmental testing for electric and electronic products - Part 2. Test methods Test Z/AD. Temperature/humidity combination Ring test GB 4208-2008 enclosure protection grade (IP code) GB/T 4365 Electrotechnical Terminology - Electromagnetic Compatibility

3 Terms, definitions and acronyms

3.1 Vehicle controller

By collecting driver driving signals, managing, scheduling, analyzing, and computing network information through the CAN bus to electric vehicles Line energy management, vehicle control system that implements vehicle drive control, energy optimization control and brake feedback control.

3.2 Electromagnetic compatibility

The ability of a device or system to function properly in its electromagnetic environment without causing unacceptable electromagnetic disturbances to anything in the environment force.

3.3 Electromagnetic disturbance

Any electromagnetic phenomenon that may degrade the performance of the device, equipment, or system or adversely affect biological or abiotic.

Note. Electromagnetic disturbances can be electromagnetic noise, unwanted signals or changes in the medium itself.

3.4 (for harassment) immunity the ability of a device,, or system to experience electromagnetic disturbances without degrading operational performance.

3.5 Electromagnetic environment

The sum of all electromagnetic phenomena present at a given location.

3.6 Immunity limit

The specified minimum immunity level.

3.7 Reference antenna

In 20MHz to 80MHz, it means a short-balanced dipole antenna with a half-wave resonant dipole at 80MHz; above 80MHz means A balanced half-wave resonant dipole tuned to the measured frequency.

3.8 Shielding room

A screen or integral metal enclosure designed to isolate indoor and outdoor electromagnetic environments. Its purpose is to block outdoor electromagnetic the field interferes with the indoor environment and prevents interference emissions from various outdoor electromagnetic activities.

3.9 Semi-anechoic chamber

In addition to the floor, the remaining inner surfaces are provided with a shielded chamber of absorbing material.

3.10 Outer casing

A component of a device that protects the device from external influences and prevents direct contact in all directions.

3.11 Degree of protection

Non-inspection method as specified by the standard, the protection provided by the enclosure to access dangerous components, prevent the entry of solid foreign objects or water ingress degree.

3.12 IP code

Indicates the degree of protection of the enclosure from access to hazardous parts, the prevention of the entry of solid foreign objects or the ingress of water, and the attachments associated with these protections.

Add information to the code system.

4 Functional status classification

This section considers the functional status of the vehicle controller after the test and test.

The undetermined operation mode is determined by the vehicle manufacturer and the component supplier.

4.1 Class A

All functions of the vehicle controller meet the actual requirements during and after the test.

4.2 Class B

All functions of the vehicle controller in the test meet the design requirements. However, one or more of the functions exceeds the specified tolerance. test all functions are automatically returned to the specified limits.

4.3 Class C

In the test, one or more functions of the vehicle controller did not meet the design requirements, but all functions automatically returned to normal operation after the test.

status.

4.4 Class D

One or more functions of the vehicle controller in the test did not meet the design requirements. All functions after the test did not automatically return to the routine in the running state, the vehicle controller needs to be reactivated.

4.4 Class E

One or more of the vehicle controllers in the test did not meet the design requirements. After the test, all functions did not return to the original state, Repair or replace the vehicle controller.

5 Specific test items

5.1 Test sequence

The vehicle controller performance test items are shown in Table 1.

Table 1 vehicle controller performance test project

5.2 General test conditions

(1) Temperature. 18 to 28 ° C; relative humidity. 45 to 75%; gas pressure 86 to 106 kPa.

(2) The accuracy of the test voltmeter shall not be less than 0.5, and the accuracy of the ammeter shall not be less than 1.0.

Serial number test category test item Power test Supply voltage range test 2 leakage current test 3 power supply reverse test 4 overvoltage test 5 voltage fluctuation test

6 Voltage interruption test

7 Short circuit test short circuit test

Environmental resistance test Low temperature start performance test 9 low temperature resistance test 10 high temperature start performance test 11 high temperature performance test 12 temperature cycle performance test

13 Vibration resistance test

14 Dustproof and waterproof performance test

15 Salt spray resistance test

16 Moisture and heat cycle performance test

Electromagnetic compatibility performance test Conducted emission test 18 radiation emission test

19 Radiated immunity performance test

20 High current injection test

21 Power transient immunity test

22 Electrostatic discharge test

(3) All kinds of measuring tools and equipment used for testing shall be within the validity period of the qualification.

In the specific test items, the tests are completed in accordance with the general test conditions, unless otherwise specified.

5.3 Specific test items

5.3.1 Power Supply Test - Power Supply Voltage Range Test this test verifies the function of the device within the minimum supply voltage and maximum supply voltage range.

Table 2 Power supply voltage range

System category

Supply voltage

Umin Umax

12V system

Pure electric 9 16

Hybrid 6 16

Conditional tests and requirements.

Key. U – voltage (V); t–time; a–frequency f=2Hz

Figure 1 Supply voltage curve

Table 3 Power supply voltage variation parameters

Category Tr/ ms t6/ ms t7/ ms t8/ s Tf/ ms Us/ V Ua/ V Functional status requirements 12V system I 5 15 50 1 40 8 9.5 Class A II 5 15 50 10 100 6 7.5 Class B

5.3.2 Power Supply Test - Withstand Voltage Test Heat the tested vehicle controller to 35 °C ± 5 °C in the test chamber; relative humidity 50% ± 5%.

Apply an alternating current (50Hz to 60Hz) voltage of 500V to the vehicle controller for 60s. The position is.

- between non-currently connected terminals;

- between conductive surfaces between the non-currently connected terminals and the outer casing;

- An electrode wrap (for example. metal foil, spherical surface) in the terminal and in a housing made of plastic material.

Requirement. The functional status satisfies the C level; there should be no breakdown or arcing.

5.3.3 Power Supply Test---Power Supply Reverse Test A test voltage UA of opposite polarity is applied simultaneously to all relevant power terminals for (60 ± 6) s.

Table 4 Power supply reverse test voltage range

category

Test voltage UA

12V system 14±0.2

Note. The required functional status meets the C level.

5.3.4 Power Test - Overvoltage Test

Table 5 Overvoltage test parameter table

category

Test temperature

Test voltage

duration

Min function status requirement 12V system 55 18±0.2 60±10% C 25 (room temperature) 24±0.2 60±10% D grade

5.3.5 Power Supply Test---Voltage Fluctuation Test Connect the tested vehicle controller as shown in Figure 2, and connect the input terminals available to the vehicle controller under test according to Table 6.

Key. 1, sweep generator; 2, power supply unit (can be modulated); 3, the vehicle controller under test; 4, positive pole; 5, ground or negative.

Figure 2 Voltage fluctuation test power supply composition

Table 6 Voltage fluctuation test parameter table

Test voltage Umax (see Figure 3) 16V (12V system) Ac voltage (sinusoidal) Upp=2V Power supply internal resistance <=100mohm Frequency range (see Figure 4) 50Hz to 20kHz Sweep type (see Figure 4) Triangle, line shape Sweep duration (see Figure 4) 120s Sweep frequency 5 Key. U-voltage (V); t-time

Figure 3 Voltage fluctuation test test voltage (sinusoidal)

Key. f-frequency (Hz); t-time (s) Requirement. Functional status meets Class A

Figure 4 Voltage fluctuation test test voltage (sweep frequency)

5.3.6 Power Test - Voltage Interrupt Test Connect test pulses to all available inputs connected to the vehicle controller under test.

Key. Umin=10.5V, rise and fall time = 10ms Requirement. Functional status meets Class B

Figure 5 voltage interrupt test waveform (12V)

5.3.7 Short circuit test Umax (12V system Umax=16V) and ground connection all relevant inputs and outputs of the tested vehicle controller for 60s, His inputs and outputs remain open or suitable.

During the experiment.

a) Power supply voltage and grounding.

1) activate the output;

2) The output stops;

b) the power supply voltage is disconnected;

c) Grounding is broken.

Requirement. The functional status satisfies the C level.

5.3.8 Environmental resistance test - low temperature work test

5.3.8.1 Initial detection Perform a visual inspection of the controller to be tested, and measure the insulation resistance between each wiring port and the fixed point in the vehicle controller.

Equal to 1Mohm. After the initial detection, connect the power cable of the vehicle controller to be tested and each test signal line.

5.3.8.2 Conditional test the vehicle controller and the fixed bracket at room temperature are placed in the test box without being installed or energized (required at this time) Take the power cord and test signal line from the box, adjust the temperature of the test chamber to -25 ° C and stabilize it, and use the forced test of the low temperature test chamber.

Air circulation to keep the temperature inside the box uniform, the air speed around the vehicle controller should not exceed 1.7m/s. If the temperature change within 1h is less than at 2 ° C, the temperature inside the test chamber is considered to be stable. The duration of the test is calculated from the time the temperature reaches a steady state and is maintained for 2 h.

5.3.8.3 Final detection Provide the rated working voltage to the tested vehicle controller for normal operation for 30 minutes, observe the working status of the tested vehicle controller and the measurement result of each parameter.

5.3.8.4 Failure criteria During the test, if one or more functions of the vehicle controller fail to meet the design requirements and need to be restarted or repaired, Then it is judged as unqualified.

5.3.9 Environmental resistance test - low temperature resistance test

5.3.9.1 Initial detection Perform a visual inspection of the controller to be tested, and measure the insulation resistance between each wiring port and the fixed point in the vehicle controller.

Equal to 1Mohm. After the initial detection, connect the power cable of the vehicle controller to be tested and each test signal line.

5.3.9.2 Conditional test the vehicle controller and the fixed bracket at room temperature are placed in the test box without being installed or energized (no need at this time) to draw the power cord and test signal line from the box, the outlet should be closed), adjust the temperature of the test chamber to -40 ° C and stabilize.

When the temperature change within 1 h is less than 2 ° C, the temperature inside the test chamber is considered to be stable. Test duration begins when the temperature reaches a steady state Calculate and keep 8h. At this time, the vehicle controller to be tested does not carry any load, and the forced air circulation of the low temperature test chamber is used to maintain the temperature inside the tank.

Evenly, the air velocity around the vehicle controller should not exceed 1.7m/s.

5.3.9.3 Recovery

After the condition test is completed, the vehicle controller to be tested is taken out from the low temperature test chamber and restored under the room temperature condition of the test chamber until Thaw, recovery time is enough to make it reach temperature stability, should not be less than 1h.

5.3.9.4 Final detection Measure whether the insulation resistance value between each wiring port and the fixed point is greater than or equal to 1 Mohm; the amount of the vehicle controller to be tested is provided.

Set the working voltage to make it work normally for 30 minutes, observe the working state of the tested vehicle controller and the measurement results of each parameter.

5.3.9.5 Failure criteria During the test, if one or more functions of the vehicle controller fail to meet the design requirements and need to be restarted or repaired, Then it is judged as unqualified.

5.3.10 Environmental Performance Test - High Temperature Performance Test

5.3.10.1 Initial detection Perform a visual inspection of the controller to be tested, and measure the insulation resistance between each wiring port and the fixed point in the vehicle controller.

Equal to 1Mohm. After the initial detection, connect the power cable of the vehicle controller to be tested and each test signal line.

5.3.10.2 Conditional test the vehicle controller and the fixed bracket at room temperature are placed in the test box without being installed or energized (required at this time) Take the power cord and test signal line from the box, adjust the temperature of the test chamber to the test temperature selected in Table 7 and stabilize it.

The forced air circulation of the low temperature test chamber keeps the temperature inside the box uniform, and the air speed around the vehicle controller should not exceed 1.7 m/s. If when the temperature change within 1 h is less than 2 ° C, the temperature inside the test chamber is considered to be stable. Test duration begins when the temperature reaches a steady state Calculate, keep 2h.

Table 7 vehicle controller high temperature performance test temperature

Product installation location test temperature Application and hybrid system and products installed near the engine 105 Produced by sunlight or applied to a hybrid system and installed under the hood Products installed in other parts 65

5.3.10.3 Final detection Provide the rated working voltage to the tested vehicle controller for normal operation for 30 minutes, observe the working status of the tested vehicle controller and the measurement result of each parameter.

5.3.10.4 Failure criteria During the test, if one or more functions of the vehicle controller fail to meet the design requirements and need to be restarted or repaired, Then it is judged as unqualified.

5.3.11 Environmental resistance test - high temperature performance test

5.3.11.1 Initial detection Perform a visual inspection of the controller to be tested, and measure the insulation resistance between each wiring port and the fixed point in the vehicle controller.

Equal to 1Mohm. After the initial detection, connect the power cable of the vehicle controller to be tested and each test signal line.

5.3.11.2 Conditional test the vehicle controller and the fixed bracket at room temperature are placed in the test box without being packaged or energized (this time Need to pull out the power cord and test signal line from the box, the outlet should be closed), adjust the temperature of the test chamber to the test selected in Table 8.

The temperature is stable and the temperature in the test chamber is considered to be stable if the temperature change within 1 h is less than 2 °C. Test duration from when the temperature reaches stable, the calculation starts and remains for 8h. At this time, the vehicle controller under test does not carry any load, and the forced air of the high temperature test chamber is utilized.

Air circulation to keep the temperature inside the box uniform, the air speed around the vehicle controller should not exceed 1.7m/s.

Table 8 Overall vehicle controller high temperature performance test temperature

Product installation location test temperature Application and hybrid system and products installed near the engine 115 Products that are exposed to sunlight or applied to a hybrid system and installed under the hood 95 Products installed in other parts 75

5.3.11.3 Recovery

After the condition test is completed, the vehicle controller to be tested is taken out from the high temperature test chamber and restored at room temperature under the test chamber.

At room temperature, the recovery time should be sufficient to achieve temperature stability and should not be lower than 1 h.

5.3.11.4 Final detection Measure whether the insulation resistance value between each wiring port and the fixed point is greater than or equal to 1 Mohm; the amount of the vehicle controller to be tested is provided.

Set the working voltage to make it work normally for 30 minutes, observe the working state of the tested vehicle controller and the measurement results of each parameter.

5.3.11.5 Failure criteria During the test, if one or more functions of the vehicle controller fail to meet the design requirements and need to be restarted or repaired, Then it is judged as unqualified.

5.3.12 Environmental resistance test - temperature cycle test

5.3.12.1 Initial ...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

How to Download T/CSAE 41-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

T/CSAE 41-2015

$315.00