Valid

SY/T 0520-2008Viscosity determination of crude petroleum. Equilibrium method by rotational viscometer (English PDF)

Preview PDF

Also coversSYT0520-2008

This is a limited preview

Buy now to download the full PDF (16 pages)

Need quotation for your management?

Get a formal quotation for SY/T 0520-2008 in 30 minutes.

Issued by

China Textile Commerce Association

Level / Type

National · Recommended

Issue date

December 1, 2015

Implementation date

March 1, 2016

Scope

SY/T 0520-2008 (Viscosity determination of crude petroleum. Equilibrium method by rotational viscometer) is available as an English-translated PDF.

SY/T 0520-2008 — This standard specifies the terms and definitions, classification, grading and marking, technical requirements, testing methods, product descriptions and packaging of PM2.5 protective masks.

This standard applies to the mask used in daily life by the public to prevent PM2.5 inhalation. This standard neither apply to the masks used for protection of harmful gases and steam inhalation, nor apply to the masks used in anoxic environment, escape, fire, medical and other occupational purposes.

Found what you need?

Document preview — SY/T 0520-2008

National Standard of the People's Republic of China

ICS
13.340.30
Classification
W 55

Issued by: China Textile Commerce Association

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative references...4
  • 3 Terms and definitions...5
  • 4 Classification, grading and marking...7
  • 5 Technical requirements...8
  • 6 Detection method...10
  • 7 Product description and packaging...13
  • Appendix A (Informative) Guidance for selection and use...15
  • Appendix B (Informative) Main dimensions of test head molds...16

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed by China Textile Commerce Association.

This standard shall be under the jurisdiction of the China Textile Commerce

Association Safety & Health Protective Products Committee.

The main drafting organizations of this standard. Chinese Academy of Sciences

Urban Environment Study Institute, CAS-Best (Xiamen) Environmental

Technology Co., Ltd., Jiande Chaomei Daily Chemicals Co., Ltd, Zhejiang State

Inspection Technology (Jiangsu) Co., Ltd. Shanghai Gangkai Purifying

Products Co., Ltd., Jingzhou Strong Science and Technology Development Co.,

Ltd, Guangzhou Powecom Safety Goods Manufacturing Co., Ltd, Guangzhou

City Guanhua Labor Protection Products Co., Ltd., Xiamen High-tech Anti-static

Equipment Co., Ltd., Hubei Xianwanli Protective Products Co., Ltd.

1 Scope

This standard specifies the terms and definitions, classification, grading and

marking, technical requirements, testing methods, product descriptions and

packaging of PM2.5 protective masks.

This standard applies to the mask used in daily life by the public to prevent

PM2.5 inhalation.

This standard neither apply to the masks used for protection of harmful gases

and steam inhalation, nor apply to the masks used in anoxic environment,

escape, fire, medical and other occupational purposes.

2 Normative references

The following documents are essential to the application of this document. For

the dated documents, only the versions with the dates indicated are applicable

to this document; for the undated documents, only the latest version (including

all the amendments) are applicable to this Standard.

GBZ 1-2010 Hygienic standards for the design of industrial enterprises

GB 2626-2006 Respiratory protective equipment - Non-powered air-purifying

particle respirator

GB/T 2912.1 Textiles - Determination of formaldehyde - Part 1.Free and

hydrolyzed formaldehyde (water extraction method)

GB 3095-2012 Ambient air quality standard

GB/T 5703 Anthropometric basic items for technical design

GB/T 7573 Textiles - Determination of pH of aqueous extract

3 Terms and definitions

The following terms and definitions apply to this document.

3.1

Mist

It refers to the tiny droplets suspended in the air.

[GB/T 18664-2002, definition 3.1.18]

3.2

Haze

It refers to a kind of weather formed by the smoke suspended in the air.

3.3

Aerodynamic diameter

It refers to the diameter of the sphere of the unit density (rho0 = 1 g/cm3)

reaching to the final settlement velocity same as the actual particle when it

is in low Reynolds movement in the static air.

[HJ 653-2013, definition 3.1]

3.4

PM2.5

It refers to the particle in the ambient air for which the aerodynamic

equivalent diameter is less than or equal to 2.5 µm, AND it is also known as

fine particle.

[GB 3095-2012, definition 3.4]

4 Classification, grading and marking

4.1 Classification

Based on structures, the products are divided into disposable masks and

replaceable masks. Based on size, the products are divided into large (L),

medium (M) and small (S).

4.2 Grading

Based on the filtration efficiency, the products are divided into. grade 1 F95 >=

95%; grade 2 F90 >= 90%.

5 Technical requirements

5.1 General requirements

5.1.1 Materials

The material shall comply with the following requirements.

5.1.2 Structural design

Structural design shall comply with the following requirements.

5.1.3 Place of production

The hygiene of the production place of mask shall comply with the Chapter 6

basic hygienic requirements for the workplace of GBZ 1-2010 Hygienic

standards for the design of industrial enterprises.

5.2 Filter efficiency

The filter efficiency will be tested in accordance with the testing methods as

specified in 6.7 of this standard; AND the filter efficiency of each sample shall

always comply with the requirements of Table 2.

5.4 Respiratory resistance

USE the test method as specified in 6.9 of this standard to conduct testing, AND

the results shall comply with the requirements of Table 4.

5.5 Connection force between mask lace and main part

USE the method as specified in 6.10 of this standard to conduct test; when the

mask lace is withstanding 10N axial tensile force for 10s, it shall not be slipping

or fracture.

6 Detection method

6.1 Appearance inspection

Based on each technical requirement, before conducting the lab performance

test, it shall conduct visual appearance inspection against the sample. As for

the disposable mask and the replaceable mask, it respectively requires

inspecting 2 samples which are respectively subjected to temperature and

humidity pre-treatment, wherein.

6.2 Temperature and humidity pretreatment

FOLLOW the provisions of 6.2.1 in GB 2626-2006.

6.3 Formaldehyde

FOLLOW the provisions of GB/T 2912.1.The samples were not pretreated AND

the samples were sealed before storage.

6.6 Microbiological indicators

FOLLOW the provisions of Appendix B of GB 15979; before test, the sample

shall be sealed.

6.7 Filter efficiency

FOLLOW the provisions of 6.3 in GB 2626-2006.TAKE 15 disposable masks

or replaceable masks, including 10 untreated samples and 5 temperature and

humidity pretreatment samples.

6.8 Total inward leakage

FOLLOW the provisions of 6.4 in GB 2626-2006.TAKE 10 disposable masks

or replaceable masks, including 5 untreated samples and 5 temperature and

humidity pretreatment samples.

6.9 Respiratory resistance

Testing equipment shall comply with the requirements of 6.5.2 in GB 2626-2006.

As for the inspiratory resistance and expiratory resistance, respectively TAKE 4

samples, including 2 untreated samples and 2 temperature and humidity

pretreatment samples. The main dimensions of the test head mold shall refer

to the requirements of Appendix B, which is divided into large, medium and

small. It shall select appropriate head mold for test based on the model size as

indicated on the tested mask.

6.11 Dead space

FOLLOW the provisions of 6.9 in GB 2626-2006.TAKE 3 samples which are

not pre-treated.

7 Product description and packaging

7.1 Product description

The product description shall provide information that the user must know,

including.

7.2 Packaging

7.2.1 The sales packaging shall protect the product against mechanical

damage and contamination prior to use;

TAJ 1001-2015

AJ

ASSOCIATION STANDARD

OF CHINA TEXTILE COMMERCE ASSOCIATION

ICS 13.340.30

W 55

Registration number

PM2.5 protective mask

Issued on. DECEMBER 1, 2015

Implemented on. MARCH 1, 2016

Issued by. China Textile Commerce Association

Table of Contents

Foreword... 3

1 Scope... 4

2 Normative references... 4

3 Terms and definitions... 5

4 Classification, grading and marking... 7

5 Technical requirements... 8

6 Detection method... 10

7 Product description and packaging... 13

Appendix A (Informative) Guidance for selection and use... 15

Appendix B (Informative) Main dimensions of test head molds... 16

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed by China Textile Commerce Association.

This standard shall be under the jurisdiction of the China Textile Commerce

Association Safety & Health Protective Products Committee.

The main drafting organizations of this standard. Chinese Academy of Sciences

Urban Environment Study Institute, CAS-Best (Xiamen) Environmental

Technology Co., Ltd., Jiande Chaomei Daily Chemicals Co., Ltd, Zhejiang State

Inspection Technology (Jiangsu) Co., Ltd. Shanghai Gangkai Purifying

Products Co., Ltd., Jingzhou Strong Science and Technology Development Co.,

Ltd, Guangzhou Powecom Safety Goods Manufacturing Co., Ltd, Guangzhou

City Guanhua Labor Protection Products Co., Ltd., Xiamen High-tech Anti-static

Equipment Co., Ltd., Hubei Xianwanli Protective Products Co., Ltd.

1 Scope

This standard specifies the terms and definitions, classification, grading and

marking, technical requirements, testing methods, product descriptions and

packaging of PM2.5 protective masks.

This standard applies to the mask used in daily life by the public to prevent

PM2.5 inhalation.

This standard neither apply to the masks used for protection of harmful gases

and steam inhalation, nor apply to the masks used in anoxic environment,

escape, fire, medical and other occupational purposes.

2 Normative references

The following documents are essential to the application of this document. For

the dated documents, only the versions with the dates indicated are applicable

to this document; for the undated documents, only the latest version (including

all the amendments) are applicable to this Standard.

GBZ 1-2010 Hygienic standards for the design of industrial enterprises

GB 2626-2006 Respiratory protective equipment - Non-powered air-purifying

particle respirator

GB/T 2912.1 Textiles - Determination of formaldehyde - Part 1.Free and

hydrolyzed formaldehyde (water extraction method)

GB 3095-2012 Ambient air quality standard

GB/T 5703 Anthropometric basic items for technical design

GB/T 7573 Textiles - Determination of pH of aqueous extract

3 Terms and definitions

The following terms and definitions apply to this document.

3.1

Mist

It refers to the tiny droplets suspended in the air.

[GB/T 18664-2002, definition 3.1.18]

3.2

Haze

It refers to a kind of weather formed by the smoke suspended in the air.

3.3

Aerodynamic diameter

It refers to the diameter of the sphere of the unit density (rho0 = 1 g/cm3)

reaching to the final settlement velocity same as the actual particle when it

is in low Reynolds movement in the static air.

[HJ 653-2013, definition 3.1]

3.4

PM2.5

It refers to the particle in the ambient air for which the aerodynamic

equivalent diameter is less than or equal to 2.5 µm, AND it is also known as

fine particle.

[GB 3095-2012, definition 3.4]

4 Classification, grading and marking

4.1 Classification

Based on structures, the products are divided into disposable masks and

replaceable masks. Based on size, the products are divided into large (L),

medium (M) and small (S).

4.2 Grading

Based on the filtration efficiency, the products are divided into. grade 1 F95 >=

95%; grade 2 F90 >= 90%.

5 Technical requirements

5.1 General requirements

5.1.1 Materials

The material shall comply with the following requirements.

5.1.2 Structural design

Structural design shall comply with the following requirements.

5.1.3 Place of production

The hygiene of the production place of mask shall comply with the Chapter 6

basic hygienic requirements for the workplace of GBZ 1-2010 Hygienic

standards for the design of industrial enterprises.

5.2 Filter efficiency

The filter efficiency will be tested in accordance with the testing methods as

specified in 6.7 of this standard; AND the filter efficiency of each sample shall

always comply with the requirements of Table 2.

5.4 Respiratory resistance

USE the test method as specified in 6.9 of this standard to conduct testing, AND

the results shall comply with the requirements of Table 4.

5.5 Connection force between mask lace and main part

USE the method as specified in 6.10 of this standard to conduct test; when the

mask lace is withstanding 10N axial tensile force for 10s, it shall not be slipping

or fracture.

6 Detection method

6.1 Appearance inspection

Based on each technical requirement, before conducting the lab performance

test, it shall conduct visual appearance inspection against the sample. As for

the disposable mask and the replaceable mask, it respectively requires

inspecting 2 samples which are respectively subjected to temperature and

humidity pre-treatment, wherein.

6.2 Temperature and humidity pretreatment

FOLLOW the provisions of 6.2.1 in GB 2626-2006.

6.3 Formaldehyde

FOLLOW the provisions of GB/T 2912.1.The samples were not pretreated AND

the samples were sealed before storage.

6.6 Microbiological indicators

FOLLOW the provisions of Appendix B of GB 15979; before test, the sample

shall be sealed.

6.7 Filter efficiency

FOLLOW the provisions of 6.3 in GB 2626-2006.TAKE 15 disposable masks

or replaceable masks, including 10 untreated samples and 5 temperature and

humidity pretreatment samples.

6.8 Total inward leakage

FOLLOW the provisions of 6.4 in GB 2626-2006.TAKE 10 disposable masks

or replaceable masks, including 5 untreated samples and 5 temperature and

humidity pretreatment samples.

6.9 Respiratory resistance

Testing equipment shall comply with the requirements of 6.5.2 in GB 2626-2006.

As for the inspiratory resistance and expiratory resistance, respectively TAKE 4

samples, including 2 untreated samples and 2 temperature and humidity

pretreatment samples. The main dimensions of the test head mold shall refer

to the requirements of Appendix B, which is divided into large, medium and

small. It shall select appropriate head mold for test based on the model size as

indicated on the tested mask.

6.11 Dead space

FOLLOW the provisions of 6.9 in GB 2626-2006.TAKE 3 samples which are

not pre-treated.

7 Product description and packaging

7.1 Product description

The product description shall provide information that the user must know,

including.

7.2 Packaging

7.2.1 The sales packaging shall protect the product against mechanical

damage and contamination prior to use;

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

Referenced standards

How to Download SY/T 0520-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SY/T 0520-2008

$110.00