Valid

SN/T 3804-2014Determination of the tri-ethylene glycol, di-ethylene glycol and water in the tri-ethylene glycol for import and export (English PDF)

进出口三甘醇中三甘醇、二甘醇和水分含量的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for SN/T 3804-2014 in 30 minutes.

Issued by

General Administration of Customs

Level / Type

National · Recommended

Issue date

January 13, 2014

Implementation date

August 1, 2014

Scope

SN/T 3804-2014 is the English-translated version of 进出口三甘醇中三甘醇、二甘醇和水分含量的测定.

SN/T 3804-2014 - This standard specifies the method for the determination of triethylene glycol, triethylene glycol, diethylene glycol and water content.

This standard applies to a purity of not less than 99.0% of the import and export triethylene glycol (used for natural gas dehydration) in triethylene glycol, diethylene glycol and water content Determination.

Found what you need?

Document preview — SN/T 3804-2014

National Standard of the People's Republic of China

ICS
71.080
Classification
G15

Issued by: General Administration of Customs

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Method summary
  • 4 Reagents and materials
  • 5 Apparatus

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

Please note that some of the content of this document may involve patents. Distribution of this document Institutions do not assume the responsibility to identify these patents.

This standard is proposed and managed by the National Certification and Accreditation Administration Committee.

This standard was drafted. Chongqing, People's Republic of China Exit Inspection and Quarantine, China Petroleum Amu Darya (Turkmenistan) natural gas well Division, the China National Petroleum Corporation, Southwest Gas Field Branch.

1 Scope

This standard specifies the method for the determination of triethylene glycol, triethylene glycol, diethylene glycol and water content.

This standard applies to a purity of not less than 99.0% of the import and export triethylene glycol (used for natural gas dehydration) in triethylene glycol, diethylene glycol and water content Determination.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat of the basic methods of reproduction GB/T 6379.4 measurement methods and results of Accuracy (trueness and precision) - Part 4. correctly determine the standard measurement method the basic method of degree Laboratory use specifications and test methods GB/T 6682-2008 Analysis

3 Method summary

Standard working solution consists of three glycol, diethylene glycol, triethylene glycol and water samples and known content, under the same operating conditions, with capillary Tube gas chromatography separation. Qualitative retention times. A standard working solution of triethylene glycol as a standard measurement standard working Liquid mass of each substance relative calibration factor, and then calculate the content of the respective components in the sample. Quantitative peak area calculation.

4 Reagents and materials

Unless otherwise indicated, all reagents were of analytical grade. Water is in line with two water GB/T 6682-2008 requirements.

4.1 TEG. certified reference materials (purity of not less than 99.00%), CAS No. 112-27-6.

4.2 Diethylene glycol. purity of not less than 99.0%, CAS No. 111-46-6.

4.3 Glycol. purity of not less than 99.0%, CAS No. 107-21-1.

4.4 Tetraethylene glycol. purity of not less than 99.0%, CAS No. 112-60-7.

4.5 hydrogen or helium. purity of not less than 99.99%.

4.6 standard working solution. Weigh a certain amount of triethylene glycol (4.1), diethylene glycol (4.2), ultra-pure water, ethylene glycol (4.3) and tetraethylene glycol (4.4) (fine Indeed to 0.1mg), dubbed the working standard solution in 10mL volumetric flask (5.5), the standard working solution with a concentration of each component should try Unknown Close. Which should be mixed TEG quality standard mass (99.0 ± 0.2)%.

5 Apparatus

5.1 Gas chromatograph. with a thermal conductivity detector (TCD), with a split/splitless capillary column with the inlet, with temperature-programmed functions

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 3804-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 3804-2014

$169.00