Valid

SN/T 3727-2013Determination of iodide content in foods for export. Ion chromatography (English PDF)

进出口食品中碘含量的测定 离子色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for SN/T 3727-2013 in 30 minutes.

Issued by

General Administration of Customs

Level / Type

National · Recommended

Issue date

November 6, 2013

Implementation date

June 1, 2014

Scope

SN/T 3727-2013 is the English-translated version of 进出口食品中碘含量的测定 离子色谱法.

SN/T 3727-2013 - This standard specifies the ion chromatographic method iodine in food exports. This standard applies to food as well as the determination of iodine in salt content of dairy products, rice and other infant nutrition.

Found what you need?

Document preview — SN/T 3727-2013

National Standard of the People's Republic of China

ICS
67.050
Classification
X04

Issued by: General Administration of Customs

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Method summary
  • 4 Reagents and materials

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

This standard is proposed and managed by the National Certification and Accreditation Administration Committee.

This standard was drafted. People's Republic of China Hunan Exit Inspection and Quarantine, Shenzhen People's Republic of China Entry-Exit Inspection and Quarantine Bureau.

1 Scope

This standard specifies the ion chromatographic method iodine in food exports.

This standard applies to food as well as the determination of iodine in salt content of dairy products, rice and other infant nutrition.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents Laboratory use specifications and test methods GB/T 6682 Analysis

3 Method summary

Infant food samples dissolved in water, ultrasonic extraction, add acetonitrile protein precipitation by centrifugation, the supernatant was removed fat RP column and other impurities, iodide ion chromatography, pulsed amperometric detector. If the sample is added potassium iodate infant food, was added at the time of extraction Ascorbic acid reducing iodate into iodine ions. Salt water sample is dissolved, iodide ion chromatography, pulsed amperometric detector inspection Measurement. If the sample is added potassium iodate salt, in the extraction of ascorbic acid was added again to restore iodate into iodine ions.

4 Reagents and materials

Unless otherwise specified, the reagents were of analytical grade above the water line with GB/T 6682 in a water requirements. Test used in the standard Standard solution, did not indicate when the other requirements, according to GB/T 602 provisions of the preparation.

4.1 acetonitrile. chromatography.

4.2 Methanol. chromatographically pure.

4.3 nitrate.

4.4 ascorbic acid.

4.5 ascorbic acid solution (5g/100mL). Weigh 5g ascorbic acid (4.4) were dissolved in 100mL water.

4.6 eluent c (HNO3) = 50mmol/L. lessons 3.12mL nitric acid (4.3), add water to 1000mL, and mix.

4.7 eluent c (HNO3) = 10mmol/L. lessons 0.63mL nitric acid (4.3), add water to 1000mL, and mix.

Potassium iodide 4.8 Standard. reference reagent purity of not less than 99.9%.

4.9 potassium iodate standard. reference reagent purity of not less than 99.5%.

4.10 standard stock solution of potassium iodide (1000mg/L). Weigh accurately 0.1308g (accurate to 0.1mg) potassium iodide (4.8), add water to dissolve, and diluted to 100mL. At 4 °C dark preservation, valid for one month.

4.11 standard potassium iodate stock solution (1000mg/L). Weigh accurately 0.1686g (accurate to 0.1mg) of potassium iodate (4.9), add water to dissolve, and diluted to 100mL. At 4 °C preservation, valid for one month.

4.12 purification column (reverse phase chromatography column, 1mL), prior to use successively with 5mL methanol (4.2), 5mL water activation.

4.13 nylon filter. 0.22µm.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 3727-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 3727-2013

$165.00