Valid

SN/T 3595-2013Zinc waste. Determination of ferrum, aluminum, calcium, magnesium, manganese, copper, titanium, chromium, nickel, vanadium and cadmium. Inductively coupled plasma atomic emission spectrometry (English PDF)

含锌废料 铁、铝、钙、镁、锰、铜、钛、铬、镍、钒和镉的测定 电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for SN/T 3595-2013 in 30 minutes.

Issued by

General Administration of Customs

Level / Type

National · Recommended

Issue date

August 30, 2013

Implementation date

March 1, 2014

Scope

SN/T 3595-2013 is the English-translated version of 含锌废料 铁、铝、钙、镁、锰、铜、钛、铬、镍、钒和镉的测定 电感耦合等离子体原子发射光谱法.

SN/T 3595-2013 - This standard specifies the inductively coupled plasma atomic emission spectrometry zinc scrap iron, aluminum, calcium, magnesium, manganese, copper, titanium, chromium, nickel, vanadium, and Cadmium method.

This standard applies to iron, aluminum, calcium, magnesium, manganese, copper, titanium, chromium, nickel, vanadium and cadmium determination of zinc waste. Measuring range of the elements shown in Table 1.

Table 1 element Measuring range Elements Fe Al Ca Mg Mn Cu Ti Cr Ni V Cd Quality Score 0.001 0.2 0.002 to 10.0 0.019 1.0 0.0089 0.5 0.0072 ~ 2.0 0.0015 to 5.0 0.0006 ~ 2.0 0.0010 ~ 2.0 0.0018 ~ 2.0 0.0012 8.0 0.0012 0.5

Found what you need?

Document preview — SN/T 3595-2013

National Standard of the People's Republic of China

ICS
77.040.30
Classification
H10

Issued by: General Administration of Customs

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Method summary
  • 4 Reagent material

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.

This standard is proposed and managed by the National Certification and Accreditation Administration Committee.

This standard was drafted. People's Republic of China Hebei Exit Inspection and Quarantine.

1 Scope

This standard specifies the inductively coupled plasma atomic emission spectrometry zinc scrap iron, aluminum, calcium, magnesium, manganese, copper, titanium, chromium, nickel, vanadium, and Cadmium method.

This standard applies to iron, aluminum, calcium, magnesium, manganese, copper, titanium, chromium, nickel, vanadium and cadmium determination of zinc waste. Measuring range of the elements shown in Table 1.

Table 1 element Measuring range

Elements Fe Al Ca Mg Mn Cu Ti Cr Ni V Cd Quality Score 0.001 0.2 0.002 to 10.0 0.019 1.0 0.0089 0.5 0.0072 ~ 2.0 0.0015 to 5.0 0.0006 ~ 2.0 0.0010 ~ 2.0 0.0018 ~ 2.0 0.0012 8.0 0.0012 0.5

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents Laboratory use specifications and test methods GB/T 6682 Analysis SN/T 1791.9-2006 imported wastes as raw materials inspection and quarantine procedures - Part 9. non-ferrous metal scrap

3 Method summary

The sample was measured for melting clean up, melted ingots after sampling, were reduced into ingots and ash representative samples, two kinds of sample points Do After digestion, after constant volume digestion solution by the carrier gas into the plasma, the wavelength corresponding to each analyte intensity, determined from the standard curve content.

4 Reagent material

Unless otherwise indicated, the reagents used were of analytical grade, water as a secondary water GB/T 6682 regulations.

4.1 nitric acid (rho = 1.42g/mL).

4.2 hydrochloric acid (rho = 1.19g/mL).

4.3 sulfate (rho = 1.18g/mL).

4.4 hydrofluoric acid. 40%.

4.5 Hydrogen peroxide. 30%.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 3595-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 3595-2013

$85.00