SN/T 3579-2013Viability detection of Phytophthora sojae Kaufmann and Gerdemann (English PDF)
大豆疫病菌活性检测方法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for SN/T 3579-2013 in 30 minutes.
Issued by
General Administration of Customs
Level / Type
National · Recommended
Issue date
March 1, 2013
Implementation date
September 16, 2013
Scope
SN/T 3579-2013 is the English-translated version of 大豆疫病菌活性检测方法.
SN/T 3579-2013 - This standard specifies the application of laser scanning confocal microscopy Phytophthora pathogen (PhytophthorasojaeKaufmann Gerdemann) method for detecting the activity.
Assay This standard applies to soybeans and soil carried Phytophthora pathogen.
Principle 2 Application of fluorescent dyes pathogen Phytophthora sojae oospores dyeing process, according to Phytophthora pathogen non-staining activity oospore After the egg plastid broken edge set, oval mass substantially uniform after the dense fluorescence and green are active oospore stained green dyeing effect difference, Using laser scanning confocal microscope to detect spores, analyze its activity situation.
Found what you need?
Document preview — SN/T 3579-2013
National Standard of the People's Republic of China
Issued by: General Administration of Customs
Contents
- Foreword
- 1 Scope
- 3 Appliances, instruments and reagents
- 3.1 Instrument appliances
- 3.2 Reagents
- 4 Activity test method
- 4.1 Get pathogen spores
- 4.2 Spore staining
- 4.3 Laser scanning confocal microscope to detect activity
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. Distribution of this document Structure does not bear the responsibility to identify these patents.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China, Shenzhen CIQ, Shenzhen Inspection and Quarantine Science Research Institute, Guangdong micro Institute of Biology, Chinese Academy of Inspection and Quarantine.
1 Scope
This standard specifies the application of laser scanning confocal microscopy Phytophthora pathogen (PhytophthorasojaeKaufmann Gerdemann) method for detecting the activity.
Assay This standard applies to soybeans and soil carried Phytophthora pathogen.
Principle 2
Application of fluorescent dyes pathogen Phytophthora sojae oospores dyeing process, according to Phytophthora pathogen non-staining activity oospore After the egg plastid broken edge set, oval mass substantially uniform after the dense fluorescence and green are active oospore stained green dyeing effect difference, Using laser scanning confocal microscope to detect spores, analyze its activity situation.
3 Appliances, instruments and reagents
3.1 Instrument appliances
Laser scanning confocal microscope, microscopes, autoclaves, biological safety cabinet, incubator, refrigerator.
3.2 Reagents
Set acridine orange, phosphate buffered saline (PBS, 0.1mol/µL, pH7.0), water agar medium.
4 Activity test method
4.1 Get pathogen spores
Under a microscope, the discovery and identification of the pathogen Phytophthora sojae oospores pick sterilized water to prepare a concentration of greater than 1 spore/µL of Spore suspension, microscopy, spare.
4.2 Spore staining
Use the concentration of 100µg/mL (solvent PBS) acridine orange stain fixed with a spore suspension of a volume mixing ratio of 1.20 uniform Together, dark staining 15min at room temperature, 16000g supernatant was centrifuged 1min termination dyeing, sterilizing deionized water once, resuspended spore Spore concentration is greater than 1/µL. Dark for backup.
4.3 Laser scanning confocal microscope to detect activity
4.3.1 Sample preparation will be completed stained slides were mounted upside down on a laser scanning confocal microscope stage, low magnification to find the spores, Go to 63 times the oil microscope, to fine-tune the image within the field of vision clear.
4.3.2 Select the appropriate laser tube (argon ion laser) fluorescence excitation signal, setting an excitation wavelength of fluorescence channels (488nm), collect fluorescent the emission wavelength of the optical signal (505nm), and set a bright field channel as a control.
4.3.3 Choose low-resolution scanning plane rough scan (xy. 512 × 512), based on the scan imaging fluorescence signal strength
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download SN/T 3579-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
SN/T 2378.1-2026 — Rules for the inspection of imported natural gas - Part 1: Pipeline inspection
SN/T 5778-2026 — Rules for the inspection of common imported and exported rare earth products
SN/T 5784-2026 — Inspection of casting and forging production processes of steel - Hot acid etching method
SN/T 3579-2013
$105.00