Valid

SN/T 2895-2011Food contact materials for export. Polymers. Determination of vinylidene chroride in food simulants. Headspace gas chromatography (English PDF)

出口食品接触材料 高分子材料 食品模拟物中偏二氯乙烯的测定 顶空气相色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (10 pages)

Need quotation for your management?

Get a formal quotation for SN/T 2895-2011 in 30 minutes.

Issued by

General Administration of Customs

Level / Type

National · Recommended

Issue date

May 31, 2011

Implementation date

December 1, 2011

Scope

SN/T 2895-2011 is the English-translated version of 出口食品接触材料 高分子材料 食品模拟物中偏二氯乙烯的测定 顶空气相色谱法.

SN/T 2895-2011 — This standard specifies the food simulants vinylidene chloride (VDC) of headspace gas chromatographic method. This standard applies to the determination of migration in food simulants vinylidene chloride (VDC) polymer materials in contact with food.

Found what you need?

Document preview — SN/T 2895-2011

National Standard of the People's Republic of China

Classification
X 08

Issued by: General Administration of Customs

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 PRINCIPLE OF THE METHOD
  • 4 Reagents and materials

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

This standard is identical with European standard EN13130-5:2004 "products and materials in contact with food - Part 5 of restricted substances in plastics Score. chloride determination "(in English) in food simulants side.

In order to meet China's national conditions and ease of use, the use of this standard in EN13130-5:2004 time made the following editorial changes, the main difference as follows.

a) Remove the EN13130-5:2004 in the previous page, directory, foreword, introduction, references and after page;

b) In the "standard" instead of EN13130-5. in 2004, "This part of this standard";

c) reference documents EN13130-1:2004 is equivalent to using the national standard GB/T23296.1-2009; included in Chapter 2 References ISO 5725-1:1994 and ISO 5725-2:1994;

d) increase "Using external standard method" in the "principle of the method" in;

e) Chapter IV agent and arrange the order of representation according to standard methods of chemical analysis of the preparation required to be altered;

f) To make the test procedure described in more rational, and in accordance with the requirements of the standard to write, the original note 2 related to Article 5.2 chromatographic conditions Content moved to Chapter 7, "GC Analysis", as 7.2.1 "chromatographic conditions" in Note 1; original 8.2 "precision" to Article 9 Chapter; original 8.2.3 "detection limit" to Chapter 10; accordingly, the original Chapter 9, "conclusive evidence" to Chapter 11; former Chapter 10, "Testing Report "to Chapter 12; corresponding changes in the provisions of the chapters numbers;

"." G) instead of a number with a decimal point as a decimal comma ",";

h) "ml" changed to "mL" representation;

i) in accordance with the provisions of the note prepared by our national standard requirements for adjustment;

j) for the convenience of a standard user, the increase in the chromatographic conditions 7.2.1 "Note 2"; increase the informative Appendix B "headspace analysis conditions" and Information Appendix D "polyvinylidene chloride and 1-chloro propane gas chromatogram"; EN13130-5:2004 Annex B to Appendix C.

This standard is proposed and managed by the National Certification and Accreditation Administration Committee.

This standard was drafted. People's Republic of China Ningbo Exit Inspection and Quarantine.

1 Scope

This standard specifies the food simulants vinylidene chloride (VDC) of headspace gas chromatographic method.

This standard applies to the determination of migration in food simulants vinylidene chloride (VDC) polymer materials in contact with food.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 23296.1-2009 plastic food contact materials restricted substances in food and food simulants to specific substances in plastics Migration testing and determination of methods and conditions of exposure to food simulants Guide selection ISO 5725-1:1994 Measurement methods and results Accuracy (trueness and precision) Part 1 General principles and definitions [Accuracy (truenessandprecision) ormearurementmethodsandresults-Part 1. Generalprinciples anddefinitions] ISO 5725-2. (trueness and precision) Section 21994 accuracy of measurement methods and results to determine the standard measurement method Repeatability and reproducibility of the basic method of [Accuracy (truenessandprecision) ormearurementmethodsand results-Part 2. Basicmethodforthedeterminationofrepeatabilityandreproducibilityofastandardmeasure-mentmethod]

3 PRINCIPLE OF THE METHOD

Use with autosampler and electron capture or flame ionization detector headspace gas chromatograph food simulants VDC content. Or using an external standard method with 1-chloro-propane (1-CP) as an internal standard added VDC as a calibrator in mimetic blank samples, quantitative Determination. If you can not get mimetic blank, use Appendix A of the standard addition method.

If the internal standard is disturbed, the external standard method for calibration. If using electron capture, should use external standard.

If you can not perform automatic headspace sampler, described in Appendix B of the manual is injected into the sample application.

VDC content can be confirmed using gas chromatography/mass spectrometry (GC/MS) method or use a different polarity GC column analysis again.

4 Reagents and materials

4.1 N, N- dimethylacetamide (DMA), a purity of greater than 99%.

4.2 vinylidene chloride (VDC), H2C = CCl2, purity greater than 99%.

4.3 chloropropane 1- (1-CP), CH3 (CH2) 2Cl, a purity of greater than 98%.

4.4 VDC stock solution of about 2.5g/kg.

Add 20mLDMA (4.1) in -20mL covered flasks or vials, capped and weighed to the nearest 0.1mg. In DMA

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 2895-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 2895-2011

$259.00