SN/T 2413-2010Determination of total carbon and sulfur contents of silicon metal for import and export. Infrared absorption spectromentry (English PDF)
进出口金属硅中总碳和硫含量测定 高频燃烧红外吸收光谱法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for SN/T 2413-2010 in 30 minutes.
Issued by
General Administration of Customs
Level / Type
National · Recommended
Issue date
January 10, 2010
Implementation date
July 16, 2010
Scope
SN/T 2413-2010 is the English-translated version of 进出口金属硅中总碳和硫含量测定 高频燃烧红外吸收光谱法.
SN/T 2413-2010 — This standard specifies the method of infrared absorption spectrometry of total carbon and sulfur content of the import and export of silicon metal in the high-frequency combustion.
This standard applies to the determination of total import and export of silicon metal in the carbon and sulfur content. Measuring range. C. 0.010% ~ 0.50%; S. 0.002% ~ 0.02%.
Found what you need?
Document preview — SN/T 2413-2010
National Standard of the People's Republic of China
- ICS
- 77.040.30
- Classification
- H 10
Issued by: General Administration of Customs
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Method summary
- 4 Reagents
- 5 Apparatus
Foreword
The Standard Appendix A and Appendix B is an informative annex.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Guangdong CIQ.
Drafters of this standard. Chen Ping, Zhang Zhenkun, Static, horse Ice.
This standard is the first release of the entry-exit inspection and quarantine industry standards.
Import and export of silicon metal in the determination of total carbon and sulfur content High frequency combustion infrared absorption spectroscopy
1 Scope
This standard specifies the method of infrared absorption spectrometry of total carbon and sulfur content of the import and export of silicon metal in the high-frequency combustion.
This standard applies to the determination of total import and export of silicon metal in the carbon and sulfur content. Measuring range. C. 0.010% ~ 0.50%; S. 0.002% ~ 0.02%.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2881 industrial silicon GB/T 4010 alloy chemical analysis and preparation of samples
3 Method summary
Sample in a high frequency induction furnace combustion heating large stream of oxygen, carbon conversion to carbon dioxide (or carbon monoxide), transformed into sulfur dioxide Oxygen introduced by the infrared detector measures the room, the detection of carbon dioxide (or carbon monoxide) and sulfur dioxide absorption of specific wavelengths of infrared energy, Concentration can be absorbed carbon and sulfur and is proportional to the measured total carbon and sulfur content.
4 Reagents
Unless otherwise stated, use only approved analytical reagent and distilled water or equivalent purity.
4.1 Water boil 30min, cooled to room temperature, pass oxygen (4.5) enables blistering 15min, prepared using.
4.2 sodium carbonate (reference material). dried over anhydrous sodium carbonate. Before use in 285 °C drying 2h, placed in a desiccator to cool.
4.3 Potassium (excellent pure). Before use to bake at 105 °C ~ 110 °C to constant weight, placed in a desiccator to cool.
4.4 magnesium perchlorate. particle size 0.7mm ~ 1.2mm.
4.5 Oxygen (99.5%).
4.6 iron flux. carbon content less than 0.001% (mass fraction).
4.7 tungsten tin flux. pure tungsten tin powder 6-4 mixing. Carbon content less than 0.001% (mass fraction).
4.8 Standard stock solution of sodium carbonate (25g/L). Weigh 55.152g sodium carbonate (4.2), was dissolved in 200mL of water, 250mL capacity moved Volumetric flask, dilute to volume, and mix. This solution 1mL containing 25mg carbon.
4.9 Potassium standard solution. Weigh potassium in Table 2 (4.3), were placed in six 100mL beaker, dissolved in water and transferred to 100mL Volumetric flask, dilute to volume, and mix.
4.10 silicon metal standard material.
5 Apparatus
5.1 frequency induction infrared carbon and sulfur analyzer. (Sensitivity 0.1 × 10-6).
5.2 micro pipettes. 100µL, the error should be less than 1µL.
5.3 tin capsules. volume about 0.4mL, carbon content less than 0.001% (mass fraction).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download SN/T 2413-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2881-2023 — Silicon metal
GB/T 28810-2012 — High-voltage switchgear and controlgear -- The use of electronic and associated technologies in auxiliary equipment of switchgear and controlgear
GB/T 28811-2012 — High-voltage switchgear and controlgear -- Digital interfaces based on IEC 61850
Secure payment via Stripe
Payments accepted
SN/T 2413-2010
$214.00