SN/T 2087-2008 — This standard specifies the determination of the chlorine content in coal by high performance liquid chromatography. This standard applies to the determination of lignite, bituminous coal and anthracite chlorine content.
Found what you need?
Document preview — SN/T 2087-2008
National Standard of the People's Republic of China
- Classification
- D 21
Issued by: General Administration of Customs
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Method summary
- 4 Reagents and materials
- 5 Apparatus
Foreword
The Standard Appendix A, Appendix B is an informative annex.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Guangdong CIQ.
Drafters of this standard. Miss Wang, Chen Wei, Yang Jun, Yang Weiguo, Sun Liangjuan.
This standard is the first release of the entry-exit inspection and quarantine industry standards.
Coal chlorine content by HPLC
1 Scope
This standard specifies the determination of the chlorine content in coal by high performance liquid chromatography.
This standard applies to the determination of lignite, bituminous coal and anthracite chlorine content.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 474 coal sample preparation GB/T 475 commercial coal sampling method
3 Method summary
Coal combustion by the oxygen bomb exploded, the chlorine contained in the coal absorbed into the alkaline reagent into Cl-, absorbed by the sample was dried with UV detection HPLC measuring device, external standard.
4 Reagents and materials
Unless otherwise specified, all reagents were of analytical grade, fresh water for the secondary double distilled water (conductivity of less than 5.5 × 10-6s/m).
4.1 ammonium carbonate.
4.2 ammonium carbonate solution (0.01mol/L). Weigh ammonium carbonate 0.9608g, dissolved in water and made up to 1000mL.
4.3 acetonitrile. HPLC fractions.
4.4 sodium hydroxide.
4.5 Sodium hydroxide solution (10mol/L). Weigh sodium hydroxide 40g, dissolved in water and made up to 100mL, through 0.45µm membrane spare.
4.6 Sodium hydroxide solution (1mol/L). Weigh sodium 4g, dissolved in water and made up to 100mL, through 0.45µm membrane spare.
4.7 two calcium chloride.
4.8 Oxygen (99.5 percent purity). no combustible components.
4.9 ion chromatography mobile phase additives (Agilent company).
4.10 Sodium chloride. pure class distinctions, at 500 °C ~ 600 °C burning 1h, after cooling stored in airtight container in the back.
4.11 sodium chloride standard stock solution. accurately weighed sodium chloride (4.10) 0.1649g, dissolved in a little water, and then transferred to 100mL volumetric flask and diluted to the mark, shake. Chloride ion concentration of the solution was 1.00mg/mL.
4.12 sodium chloride standard solution. Pipette 10mL1.00mg/mL standard stock solution (4.11) to a 100mL volumetric flask, to volume, shake, chloride ion concentration of the solution was 0.100mg/mL.
Preparation of the mobile phase of 4.13. Pipette 810mL of double distilled water twice stamped vacuum 15min, add 50mL mobile phase additives (4.9), Vacuum 5min, added 140mL acetonitrile (4.3), while being vacuumed (4.5) adjusted to pH 7.0 with sodium hydroxide solution, and then hydrogen Sodium hydroxide solution (4.6) adjusted to pH 8.6 ± 0.1, continuing the vacuuming 15min.
5 Apparatus
5.1 High performance liquid chromatograph. equipped with a UV detector.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 474 · GB/T 475
How to Download SN/T 2087-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4740-2024 — Test method for strength of ceramic materials
GB/T 47400-2026 — X-ray digital imaging method for the inspection of welded joints in polyethylene pipes for petrochemical use
GB/T 47401-2026 — Test method for lithium-ion battery cathode materials - Determination of slurry viscosity
Secure payment via Stripe
Payments accepted
SN/T 2087-2008
$85.00