Valid

SN/T 1589.13-2012Rules for the inspection of household and similar electrical appliances for import and export. Part 13: Air-conditioner (English PDF)

进出口家用和类似用途电器检验规程 第13部分:空调器

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for SN/T 1589.13-2012 in 30 minutes.

Issued by

General Administration of Customs

Level / Type

National · Recommended

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

SN/T 1589.13-2012 is the English-translated version of 进出口家用和类似用途电器检验规程 第13部分:空调器.

SN/T 1589.13-2012 — SN/T 1589 provisions of this part of the import and export of air conditioners for household and similar use of sampling, testing and judgment.

This section applies equipped with fully enclosed motor - compressors and fan coil room air conditioners, single-phase maximum rated voltage not exceeding 250V.

Found what you need?

Document preview — SN/T 1589.13-2012

National Standard of the People's Republic of China

Classification
C 09
Replacing
SN/T 0613.1-1996; SN/T 0613.2-1996

Issued by: General Administration of Customs

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

SN/T 1589 "Household and similar electrical appliances import and export inspection procedures" is divided into 15 parts.

--- Part 1. General requirements;

--- Part 2. vacuum cleaners and water suction cleaner;

--- Part 3. storage water heaters;

--- Part 4. radiant heater;

--- Part 5. humidifiers;

--- Part 6. sewing machine;

--- Part 7. air purifiers;

--- Part 8. massage apparatus;

--- Part 9. food waste disposers;

--- Part 10. Electric shoe polisher;

--- Part 11. thermal storage hand warmers;

--- Part 12. far-infrared heating products;

--- Part 13. Air conditioner;

--- Part 14. Hot and cold drinking fountains;

--- Part 15. motor - compressors.

This section SN/T Part of 131,589.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The partial replacement of SN/T 0613.1-1996 "Importers room air conditioner safety inspection procedures" and SN/T 0613.2-1996 "Importers and room air conditioner performance test procedures" this section compared with the SN/T 0613.1-1996, SN/T 0613.2-1996, the main technical changes are as follows.

--- Standard name, the use of larger modifications;

--- Increased inspection and supervision model and content inspection methods, and clearly specifies the requirements for different test methods of test items its corresponding test methods;

--- Increased electromagnetic compatibility, environmental testing requirements.

This section proposed and managed by the National Certification and Accreditation Administration Committee.

Introduction

"Importers of household and similar electrical appliances - Test procedures - Part 13. Air conditioner" is the import and export inspection and air conditioners for household and similar purposes Based on the work of the import and export of household and similar air conditioner inspection play a guiding and regulating.

With China's accession to the World Trade Organization (WTO) and the "People's Republic of China Import and Export Commodity Inspection Law" and its implementing regulations amended Import and Export Commodity Inspection, great changes occurred in work mode. In order to meet changes in the form, the state inspection and quarantine departments in charge of the establishment of a Inspection and quarantine standards.

This part belongs to the standard system of inspection and quarantine fourth floor --- personality, with special inspection requirements for the provision of air conditioner characteristics.

Import and export of household and similar electrical appliances inspection procedures Part 13. Air Conditioner

1 Scope

SN/T 1589 provisions of this part of the import and export of air conditioners for household and similar use of sampling, testing and judgment.

This section applies equipped with fully enclosed motor - compressors and fan coil room air conditioners, single-phase maximum rated voltage not exceeding 250V.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 2828.1 Sampling procedures for inspection - Part 1; batch inspection sampling plan by acceptance quality limit (AQL) retrieval GB 4343.1 EMC household appliances, electric tools and similar apparatus - Part 1. Emission Particular requirements GB 4706.32-2004 household and similar electrical appliances - Safety heat pumps, air conditioners and dehumidifiers GB 12021.3 room air conditioner energy efficiency limit value and energy efficiency rating GB 17625.1 Electromagnetic Compatibility Limits for harmonic current emissions (equipment input current <=16A) GB 19606 Household and similar electrical noise limits SN/T 2838.2 specializing in import and export of electromechanical products inspection General requirements - Part 2. Terms and definitions

3 Terms and Definitions

GB 4706.32 and SN/T 2838.2 and define the following terms and definitions apply to this document.

Sampling mode modeofsamplinginspection According to the mandatory requirements of national technical specifications, import and export commodities random inspection lot or batch embodiment qualified sampling, testing and inspection Assessment activities.

Type Test mode modeoftypetest According to a predetermined cycle based on the mandatory requirements of national technical specifications type testing, according to on-site inspection requirements for product pumping batch inspection Inspection, supervision and implementation of the conformity assessment activities of the enterprise quality management system.

Compliance Verification mode modeofcomplianceverification According to the mandatory requirements of national technical specifications, inspection certificate and inspection documents, goods are consistent with the random testing can be carried out when necessary, and real Shi conformity assessment activities supervision.

Inspection Lot for the implementation of sampling and collection of the same specifications, models, produced under the same conditions of production per unit of product, referred to as batch.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 1589.13-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 1589.13-2012

$214.00