Valid

SH/T 1827-2019Plastics. Determination of crystallinity. X-ray diffraction (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for SH/T 1827-2019 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 24, 2019

Implementation date

July 1, 2020

Scope

SH/T 1827-2019 (Plastics. Determination of crystallinity. X-ray diffraction) is available as an English-translated PDF.

SH/T 1827-2019 — This standard specifies the method for determining the crystallinity of polyethylene (PE) and polypropylene (PP) by X-ray diffraction this standard is applicable to the determination of crystallinity of granular or powdered polyethylene and polypropylene (alpha crystal form, beta+alpha crystal form) compression-molded or injection-molded specimens this standard does not apply to the determination of the crystallinity of filled polyethylene and polypropylene Note.

The determination of the crystallinity of polyethylene and polypropylene products can refer to this standard. The high ethylene content ethylene-propylene copolymer polypropylene can also refer to this standard.

Found what you need?

Document preview — SH/T 1827-2019

National Standard of the People's Republic of China

ICS
83.080.01
Classification
G 31

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Method summary
  • 5 Reference materials
  • 6 Equipment
  • 6.1 X-ray diffractometer
  • 6.2 Software
  • 7 Samples
  • 7.1 Sample preparation
  • 7.2 Sampling
  • 8 Condition adjustment
  • 9 Test procedure
  • 9.1 Test conditions
  • 9.2 Calibration instrument
  • 9.3 Set the working conditions of the instrument
  • 9.4 Test
  • 10 Test data processing
  • 10.1 Get the 2theta value of the peak position and the count value of the peak area
  • 10.2 Calculation
  • 10.3 Presentation of results
  • 11 Precision

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009 this standard was proposed by China Petrochemical Corporation this standard is under the jurisdiction of the Petrochemical Plastic Resin Products Branch of the National Plastics Standardization Technical Committee (SAC/TC15/SC1) Responsible for drafting this standard. China National Petroleum Corporation Petrochemical Research Institute, Beijing Yanshan Petrochemical High-tech Technology Company Limited liability company Participated in the drafting of this standard. Tianjin University, Shanghai Jiaotong University, China Petroleum & Chemical Corporation Beijing Research Institute of Chemical Industry, China Petroleum & Chemical Corporation Zhenhai Refining & Chemical Company, China National Petroleum Corporation Liaoyang Petrochemical Company, Bruker (Beijing) Technology Co., Ltd., Thermo Fisher Scientific (China) Co., Ltd., Dandong Haoyuan Instrument Co., Ltd., Dandong Tongda Technology Co., Ltd.

Co., Ltd., Shanghai Ruoyi New Material Technology Co., Ltd.

1 Scope

This standard specifies the method for determining the crystallinity of polyethylene (PE) and polypropylene (PP) by X-ray diffraction this standard is applicable to the determination of crystallinity of granular or powdered polyethylene and polypropylene (alpha crystal form, beta+alpha crystal form) compression-molded or injection-molded specimens this standard does not apply to the determination of the crystallinity of filled polyethylene and polypropylene Note. The determination of the crystallinity of polyethylene and polypropylene products can refer to this standard. The high ethylene content ethylene-propylene copolymer polypropylene can also refer to this standard.

2 Normative references

The following documents are indispensable for the application of this document. All dated reference documents only the dated version applies to this article the latest version (including all amendments) of undated reference documents is applicable to this document GB/T 1845.2 Plastic Polyethylene (PE) Molding and Extrusion Materials Part 2: Sample Preparation and Performance Determination GB/T 2546.2 Plastic polypropylene (PP) Moulding and extrusion materials Part 2: Sample preparation and performance measurement GB/T 2918 Standard environment for condition adjustment and testing of plastic samples JJG 629-2014 Polycrystalline X-ray Diffractometer

3 Terms and definitions

The following terms and definitions apply to this document 3.1 Crystallinity (X-ray diffraction method) the degree of crystallinity calculated based on the percentage of the contribution of the crystal region in the total area of the X-ray diffraction intensity peaks of the partially crystalline polymer[1]Xc

4 Method summary

The crystallinity of the polymer is proportional to the integrated area of the X-ray diffraction peaks of the crystalline phase. Collect 2theta at an angle of 5° under the specified test conditions.

The copper Kalpha X-ray diffraction data of the sample within the range of 35° is obtained by using the chemometric peak analysis software to obtain the measured crystal plane diffraction peak and amorphous scattering the peak 2theta angle and peak area count value are calculated by the ratio of the sum of the peak area of the crystalline peak and the sum of the sum of the peak area of the amorphous peak.

Kind of crystallinity

5 Reference materials

Powder alpha-SiO2 or Si standard material that meets the technical requirements of JJG 629-2014

6 Equipment

6.1 X-ray diffractometer

The X-ray diffractometer that meets the technical requirements of JJG 629-2014 is equipped with a copper target (Kalpha radiation). The rotating sample stage instrument is as per JJG the stability of the diffraction intensity measured in 629-2014 for 8 hours is not more than 1.5% (expressed as relative range) Note. If the instrument's optical system configuration or adjustment is improper, the scattered light will enter the detector at a low angle and a bun peak will appear on the background, and the instrument cannot be completed.

Determination of crystallinity

6.2 Software

X-ray diffraction data processing software with Pearson VII peak splitting program

7 Samples

7.1 Sample preparation

7.1.1 Preparation of PE sample

Use compression molding (Q) or injection molding (M) methods to prepare specimens according to GB/T 1845.The specimen thickness is 1.0mm ± 0.1mm

7.1.2 Preparation of PP sample

Use compression molding (Q) or injection molding (M) methods to prepare specimens according to GB/T 2546.The specimen thickness is 1.0 mm ± 0.1 mm

7.2 Sampling

Use punching equipment or ruler and blade to cut a test piece in the middle of the sample prepared by compression molding (Q) or injection molding (M) method. The test piece is required.

Flat as a mirror surface without bending The test surface is clean and free from dust and other mechanical impurities and kept dry. The size of the test piece is as specified by the instrument used.

Note. When sampling from the product, machine processing or other suitable methods can be used to prepare a slice of 1.0mm ± 0.1mm from the product and then sample according to the above method

8 Condition adjustment

According to GB/T 2918, the state is adjusted at a temperature of 23°C ± 2°C. The state adjustment time is in accordance with GB/T 1845.2 and GB/T 2546.2.

9 Test procedure

9.1 Test conditions

Test according to GB/T 2918 at a temperature of 23°C±2°C

9.2 Calibration instrument

Start the X-ray diffractometer (6.1) and use the standard material (5) to verify that the diffraction intensity of the instrument is not greater than the stability of the instrument 1.5%/8 hours (expressed in relative range)

9.3 Set the working conditions of the instrument

Set the working conditions of X-ray diffractometer (see Table 1)

9.4 Test

Do two tests in parallel, install the debugging film on the X-ray diffractometer sample table, close the sample room and start the test

10 Test data processing

10.1 Get the 2theta value of the peak position and the count value of the peak area

Use the data processing software configured with the X-ray diffractometer to first perform the Save-Golay 9 points or the X-ray diffraction data of the sample.

11-point parabolic smooth stripping Kalpha2 subtracts the background (B.G.), and then uses the Pearson-VII peak splitting program to perform peak shape fitting.

The peak shape of the radiation curve is divided into the crystal diffraction peak and the amorphous scattering peak to obtain the 2theta value of the peak position of the crystal diffraction peak and the amorphous scattering peak of the tested sample.

Amorphous scattering peaks and symmetrical crystal diffraction peaks should be symmetrically fitted to the peak area count value. If the measured crystal diffraction peaks are asymmetric the asymmetric fitting is performed according to its peak shape

Note 1.The 2theta value of the peak position of the amorphous scattering peak in the literature is not uniform, and there is an unreasonable phenomenon in some literature that the asymmetrical splitting of the amorphous scattering peak

Note 2.For the typical stoichiometry of PE and PP (alpha crystal form, beta+alpha crystal form) (Pearson-VII), see Appendix A for the peak shape fitting diagram

10.2 Calculation

Calculate the crystallinity of the tested sample according to formula (1). Appendix B is the factor in formula (1) and the calculation method of the coefficient in the calculated formula.

10.3 Presentation of results

Take the arithmetic average of the two parallel determination results as the determination result data and keep one decimal place

11 Precision

In.2018, X-ray diffraction method was carried out to determine the crystallinity of 3 typical PE and 4 typical PP compression molded samples in 8 laboratories.

The precision test of each laboratory repeats the measurement for each sample twice. The precision calculation results are shown in Table 2.

Note 1.The precision of this standard is calculated according to GB/T 6379.2-2004[2], where Sr is the repeatability standard deviation, and SR is the reproducibility standard deviation and r is the repeatability.

Limit R is the limit of reproducibility

Note 2.The samples for the precision test are selected from samples with a crystallinity of 37.8% to 81.2% the test report should include the following.

a) Indicate the reference to this standard.

b) All data and information of the test sample.

c) The working conditions of the instrument.

d) Details of sample preparation, sampling and sample state adjustment, test conditions, etc.

e) Sample size,

f) The test results include the two test results and the arithmetic mean value.

g) Details of any abnormal phenomena observed in the measurement and their descriptions, such as unqualified background, inconsistent crystal form of the sample, etc.

h) Date of analysis, etc.

Appendix A

(Informative appendix) PE and PP (alpha crystal form, beta+alpha crystal form) typical stoichiometry (Pearson-VII) peak shape fitting graph

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

How to Download SH/T 1827-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SH/T 1827-2019

$245.00