Valid

QC/T 823-2009Fuel level sensors for automobiles and motorcycles (English PDF)

汽车、摩托车用燃油传感器

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for QC/T 823-2009 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

November 17, 2009

Implementation date

April 1, 2010

Scope

QC/T 823-2009 is the English-translated version of 汽车、摩托车用燃油传感器.

QC/T 823-2009 is the Chinese standard "Fuel level sensors for automobiles and motorcycles". Its scope clause reads: This standard specifies the classification, requirements, test methods, inspection rules and markings, packaging, storage, and maintenance of fuel sensor for automobile and motorcycle (hereinafter referred to as the sensor).

This standard applies to fuel sensor for automobile and motorcycle. Fuel sensor for other motor vehicles shall also be implemented with reference to this standard.

Its clauses include classifications; requirements; test methods; marking, packaging, storage and safekeeping.

Found what you need?

Document preview — QC/T 823-2009

National Standard of the People's Republic of China

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword5
  • 1 Scope6
  • 2 Normative references6
  • 3 Classifications6
  • 4 Requirements6
  • 5 Test methods9
  • 6 Inspection rules11
  • 7 Marking, packaging, storage and safekeeping12

1 Scope

This standard specifies the classification, requirements, test methods, inspection rules and markings, packaging, storage, and maintenance of fuel sensor for automobile and motorcycle (hereinafter referred to as the sensor).

This standard applies to fuel sensor for automobile and motorcycle. Fuel sensor for other motor vehicles shall also be implemented with reference to this standard.

2 Normative references

The articles contained in the following documents have become part of this standard when they are quoted herein. For the dated documents so quoted, all the modifications (excluding corrections) or revisions made thereafter shall not be applicable to this standard. For the undated documents so quoted, the latest editions shall be applicable to this standard.

QC/T 727-2007 Instrument for automobile and motorcycle

QC/T 29106 Technical specification of low-voltage electric harness for motor vehicles

3 Classifications

Sensors shall be classified into 3 types – resistance-type, capacitance-type, and pressure-type. Resistance-type sensors are divided into 2 types - reed variable-resistance sensors, and sliding variable-resistance sensors.

4 Requirements

4.1 General provisions

4.1.1

Product documentation:

4.1.1.1

The sensors shall conform to the requirements of this standard. And it shall be manufactured according to the drawings and design documents approved by the specified procedures.

4.1.1.2

Appearance and mounting dimensions of the sensors shall conform to the provisions of the product drawings.

4.10 Durability

The sensor shall be able to withstand 30,000 times of alternating cycle inspections. Its parts shall have no abnormal changes during the inspection. After the inspection, the variation of indication value shall not exceed 7% of the nominal value of the measured point; it shall conform to the provisions of 4.3, before and after the inspection.

4.11 Oil resistance

The sensor shall be able to withstand the immersion in the alcohol, gasoline or diesel.

After the inspection, the mechanical part and rubber part shall be free of the defects such as deformation, color change and cracks. And it shall conform to the provisions of 4.3 and 4.4.

4.12 Gas tightness

For gas tightness inspection, pressure gauge reading of the sensor shall remain unchanged in 10s. And no bubbles shall occur at the sealing part.

5 Test methods

5.1 Test conditions

5.1.1

Output value test of the sensor shall be conducted under the environment conditions specified in 4.1.2.

5.1.2

The accuracy of digital multimeter for the test shall be ± 0.5.

5.1.3

The accuracy of steel gauge shall be ± 1mm.

5.1.4

The accuracy of standard thermometer shall be ± 1°C.

5.2 Appearance

For appearance inspection, it shall be inspected with an average illumination of about

3001x; eye distance of 500mm; and visual inspection.

5.3 Basic error test

The test shall be conducted on the special equipment. The height deviation of the special equipment shall be ±2mm. During the test, the liquid level shall be changed steadily from UP (Full 1) to DOWN (Empty 0); output value at 1, 1/2, alarming point, and 0 shall be measured by using multimeter. During the test, indication value can be read only after it remains at the test reference line for at least 1min. State of the movable part shall be inspected in the test.

5.4 Insulation and voltage resistance test

It shall be conducted according to the provisions 5.8 in QC/T 727-2007.

5.5 Temperature change resistance test

It shall be conducted according to the provisions 5.9 in QC/T 727-2007.

5.6 Temperature effect test

5.6.1 Test points

Conduct the inspection only at 1/2 place.

5.6.2 High-temperature effect test

Firstly, INSPECT the output value of the sensor under the specified environment condition specified in 4.1.2. Then PLACE the sensor into the high temperature cabinet. MAINTAIN the temperature for 2 hours after the cabinet temperature rises to 80°C±2°C. INSPECT the output value according to the methods specified in 5.3. OBTAIN the difference of output value between high temperature and the environment condition specified in 4.1.2. Output value test under high temperature can be conducted outside the cabinet, but it shall be done within

2min. Then TAKE out the sensor. PLACE it under the environment condition specified in 4.1.2 for no less than 2 hours. INSPECT the state and output value of movable part according to the methods specified in 5.3.

5.6.3 Low-temperature effect test

Firstly, INSPECT the output value of the sensor under the specified condition specified in 4.1.2. Then PLACE the sensor into the low temperature cabinet. MAINTAIN the temperature for 2 hours after the cabinet temperature rises to -40°C±3°C. INSPECT the output value according to the methods specified in 5.3. Then OBTAIN the difference of output value under low temperature and the environment condition specified in 4.1.2. Output value test under low temperature can be conducted outside the cabinet, but it shall be done within 2min.

Then TAKE out the sensor. PLACE it under the environmental condition specified in 4.1.2 for no less than 2h. INSPECT the state and output value of movable part according to methods specified in 5.3.

5.7 Temperature resistance and humidity cycling test

It shall be conducted according to the provisions 5.11 in QC/T 727-2007.

5.8 Vibration resistance test

It shall be conducted according to the provisions 5.17 in QC/T 727-2007. After the test,

INSPECT if the parts are loosened or damaged. PLACE the sensor under the environment condition specified in 4.1.2 for at least 2 times. Then INSPECT the status and output value of the movable part according to the methods specified in 5.3.

5.9 Durability test

INSTALL the sensor on the test stand according to normal working position; MAKE the sensor rise and FALL cyclically with the frequency of 6~10 times per minute so […]

6.4 Acceptance inspection

It shall be conducted according to the provisions 6.4 in QC/T 727-2007.

6.5 Type inspection

6.5.1

The conditions when type inspection shall be conducted:

It shall be conducted according to the provisions 6.5.1 in QC/T 727-2007.

6.5.2

Sampling and grouping:

6.5.2.1

Products for type inspection shall be sampled from the same batch of products that have been inspected as qualified for ex-factory inspection. At least 9 products shall be sampled.

6.5.2.2

Re-inspection shall be performed according to ex-factory inspection items.

Then the samples are divided into 3 groups after they pass the re-inspection. Conduct the inspection according to the following grouping and the item order.

— Group 1: Insulation and voltage resistance test, oil resistance test, gas tightness test;

— Group 2: Temperature change resistance test, temperature effect test, temperature resistance and humidity cycling test, vibration resistance test;

— Group 3: Durability test.

Note: For the entrusted test, the sampling and grouping of the samples shall be determined through negotiation with the manufacturer, but the number of inspected samples shall not be less than 3 for each inspected item.

6.6 Qualified determination

It shall be conducted according to the provisions 6.5.3 in QC/T 727-2007.

7 Marking, packaging, storage and safekeeping

Perform it according to the provisions specified in Chapter 7 of QC/T 727-2007.

__________ END __________ […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download QC/T 823-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

QC/T 823-2009

$70.00