Scope

QC/T 695-2002 is the English-translated version of 汽车通用继电器.

QC/T 695-2002 is the Chinese standard "General-purpose relays for automobiles". Its scope clause reads: This Standard specifies the technical requirements, test methods and inspection rules, mark, package, storage and preservation of automotive general-purpose relay.

This Standard is applicable to the automotive DC circuit mechanical contact type electromagnetic relay (including plug-in small general-purpose relays and other installation of relays, hereinafter referred to as relay). Its clauses include definitions.

Found what you need?

Document preview — QC/T 695-2002

National Standard of the People's Republic of China

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative References4
  • 3 Definitions4
  • 4 Requirements5
  • 5 Test Methods8
  • 6 Inspection Rules10
  • 7 Mark, Package, Storage and Preservation11

1 Scope

This Standard specifies the technical requirements, test methods and inspection rules, mark, package, storage and preservation of automotive general-purpose relay.

This Standard is applicable to the automotive DC circuit mechanical contact type electromagnetic relay (including plug-in small general-purpose relays and other installation of relays, hereinafter referred to as relay).

2 Normative References

The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.

GB/T 2408-1996 Plastics-Determination of the Burning Behaviour of Horizontal and Vertical Specimens in Contact with a Small-Flame Ignition Source

JB/T 4159-1999 General Technical Requirements for Electric Products in the

Tropics

QC/T 73 Method of Compiling Model of Automobile Electric Equipment Product

QC/T 78-1993 Automotive Plug-In Relay and Flasher Mounting Dimension

QC/T 413-2002 Basic Technical Requirements for Automotive Electric Equipment

3 Definitions

This Standard adopts the following definitions.

3.1 Normally open contact

The contact that is in the disconnecting state, when the relay coil is not energized.

3.2 Normally closed contact

4.8.2 High-temperature resisting property

The relay can work as per the requirements in the upper limit working temperature stipulate din Table 1 of QC/T 413; and perform high-temperature test for 8h as per the selected upper limit storing temperature; when restoring to the room temperature, the relay’s operating voltage, release voltage and contact voltage drop shall meet the requirements of 4.6.1 and 4.6.2.

4.8.3 Temperature-change resisting property

Perform the temperature-change resisting property test as per the requirements of 3.10.3 of QC/T 413; after the completion of test and the temperature restoring to the room temperature, the relay’s operating voltage, release voltage and contact voltage drop shall meet the requirements of 4.6.1 and 4.6.2.

4.9 Product temperature-and-humidity-change resisting property

Perform the temperature-and-humidity-change resisting property test as per the requirements of 3.11 of QC/T 413; after the completion of test and temperature restoring to the room temperature, the relay’s contact voltage drop shall meet the requirements of 4.6.2.

4.10 Vibration property

Under non-working conditions, the installation position shall be “other positions” according to Table 3 in 3.12 of QC/T 413, the relay shall withstand sweep vibration test from three directions, namely, X, Y, Z; after the completion of test, relay shall meet the requirements of 4.6.1 and 4.6.2.

4.11 Salt spray resisting property

Under non-working conditions, according to the provisions of 3.13 of QC/T 413, perform 48h salt spray test against the relay; after the completion of test, the relay’s operating voltage and release voltage shall meet the requirements of 4.6.1.

4.12 Durability

The working times for relay durability shall be 100 000 times, which can also be determined by the client’s specific demand. After the durability test, the relay’s operating voltage and release voltage shall conform to the provisions of 4.6.1;

compared with Table 3, the contact voltage drop can increase 50%.

5.7 Insulation and voltage resisting test

Perform the insulation and voltage resisting test against the specimen according to the method stipulated in 4.8.1 of QC/T 413; which shall conform to the provisions of 4.7.

5.8 Temperature resisting property test

5.8.1 Low-temperature test

Firstly, check whether the relay can start under the lower limit working temperature;

then perform the low-temperature storing test according to the test methods stipulated in 4.10.1 of QC/T 413; after the completion of the test, placing the relay under room temperature for 1h, its property shall conform to the provisions of 4.8.1.

5.8.2 High-temperature test

Firstly, check whether the relay can start under the upper limit working temperature;

then perform high-temperature storing test according to the test methods stipulated in 4.10.2 of QC/T 413; after the completion of the test, placing the relay under room temperature for 1h, its property shall conform to the provisions of 4.8.2.

5.8.3 Temperature-change test

Perform the temperature-change test according to the test methods stipulated in 4.10.3 of QC/T 413; after the completion of the test, placing the relay under room temperature for 1h, its property shall conform to the provisions of 4.8.3.

5.9 Composite temperature/humidity cycling test

Perform the composite temperature/humidity cycling test according to 4.11 of QC/T 413; after the completion of test, and restoring to the room temperature; the relay property shall conform to the provisions of 4.9.

5.10 Vibration test

Perform the test according to the methods stipulated in 4.12 of QC/T 413; after the completion of test, the relay property shall conform to the provisions of 4.10.

5.11 Salt spray test

Perform the salt spray test for 48h according to 4.13 of QC/T 413; after the completion of test, the relay property shall conform to the provisions of 4.11.

5.12 Durability test

Perform the durability test against the relay according to the prescribed wiring mode and load property parameters; one cycle (or one time) of test indicates the test is energized for 2s and not energized for 3s; after the completion of test, the property […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

How to Download QC/T 695-2002

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

QC/T 695-2002

$55.00