QC/T 1266-2025Fuel cell electric vehicles - Specifications for online monitoring of onboard hydrogen systems (English PDF)

燃料电池电动汽车 车载氢系统在线监测技术规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (25 pages)

Need quotation for your management?

Get a formal quotation for QC/T 1266-2025 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

December 17, 2025

Implementation date

July 1, 2026

Scope

QC/T 1266-2025 is the English-translated version of 燃料电池电动汽车 车载氢系统在线监测技术规范.

QC/T 1266-2025 sets out the technical requirements and test methods for online monitoring of hydrogen concentration, pressure and temperature in the onboard hydrogen system of fuel cell electric vehicles, and applies to onboard hydrogen systems using compressed gaseous hydrogen.

It defines the monitoring system as one that follows these parameters in real time and provides data acquisition, storage, uploading and safety alarm functions.

Clause 4 requires the system to work with the vehicle started and not started, the communication protocol towards the upper-level data platform to comply with GB/T 32960.3, at least a hydrogen concentration sensor, a temperature sensor and a pressure sensor to be connected, and a power failure protection device or equivalent measures to keep the system running for no less than 12 hours when the vehicle is not started.

High-pressure and low-pressure sensors are fitted separately, the first to be placed near the hydrogen storage cylinder opening and the second after the pressure regulator and near the fuel cell system.

Hydrogen leakage alarms and pressure alarms, covering low pressure and overpressure, must each be graded into at least two risk levels with adjustable thresholds; temperature monitoring must raise a low temperature or over-temperature alarm at the set threshold.

The stated limits are a missing alarm rate not exceeding 1% and a false alarm rate not exceeding 3% for hydrogen concentration, and 3% and 5% for pressure. Clause 5 gives the test conditions and the alarm test for each parameter, and informative appendices add a system schematic and recommended sensor indices.

Found what you need?

Document preview — QC/T 1266-2025

National Standard of the People's Republic of China

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions4
  • 4 Requirements5
  • 4.1 General requirements5
  • 4.2 Hydrogen concentration monitoring alarm6
  • 4.3 Pressure monitoring alarm6
  • 4.4 Temperature monitoring alarm7
  • 4.5 Data processing8
  • 5 Test methods9
  • 5.1 Test conditions9
  • 5.2 Hydrogen concentration monitoring alarm test9
  • 5.3 Pressure monitoring alarm test10
  • 5.4 Temperature monitoring alarm test11
  • Appendix A (Informative) Schematic diagram of the online monitoring system of onboard hydrogen system13
  • Appendix B (Informative) Technical indices of sensors for online monitoring of onboard hydrogen systems14
  • References15

1 Scope

This document specifies the technical requirements and test methods for online monitoring of parameters such as hydrogen concentration, pressure, and temperature in the onboard hydrogen system of fuel cell electric vehicles.

This document applies to onboard hydrogen systems for fuel cell electric vehicles that use compressed gaseous hydrogen.

2 Normative references

The provisions of the following documents constitute the essential clauses of this document through normative references in this text. Among them, for any dated reference, only the version corresponding to that date applies to this document; for any undated reference, the latest version (including all amendments) applies to this document.

GB/T 24548 Fuel cell electric vehicles - Terminology

GB/T 24549-2020 Fuel cell electric vehicles - Safety requirements

GB/T 26990 Fuel cell electric vehicles - Onboard hydrogen system technical specifications

GB/T 32960.2 Technical specifications for remote service and management system for electric vehicles - Part 2: On-board terminal

GB/T 32960.3 Technical specifications for remote service and management system for electric vehicles - Part 3: Communication protocol and data format

3 Terms and definitions

The terms and definitions defined in GB/T 24548 and GB/T 26990, as well as the following terms and definitions, apply to this document.

3.1 Online monitoring system of onboard hydrogen system

The system that monitors parameters such as hydrogen concentration, pressure, and temperature in real time, and features data acquisition, storage, uploading, and safety alarm functions.

NOTE: Hereinafter referred to as "monitoring system". See Appendix A for a schematic diagram of the online monitoring system of onboard hydrogen system.

3.2 Missing alarm rate

The percentage of times the system fails to issue an alarm signal or indicator for the designed alarm events out of the total number of tests.

3.3 False alarm rate

The percentage of times the system responds to an unplanned event by issuing an alarm signal or indication out of the total number of tests.

3.4 Upper-level data platform

Data management platforms for fuel cell electric vehicles built by government departments, industry organizations, or enterprises.

4 Requirements

4.1 General requirements

4.1.1 The monitoring system shall monitor the hydrogen concentration, pressure, and temperature parameters of the onboard hydrogen system in real time, and shall have data acquisition, storage, uploading, and safety alarm functions.

4.1.2 The monitoring system shall operate normally with the vehicle started and not started.

4.1.3 The communication protocol between the monitoring system and the upper-level data platform shall comply with the requirements of GB/T 32960.3.

4.1.4 The sensors connected to the monitoring system shall include at least a hydrogen concentration sensor, a temperature sensor, and a pressure sensor. The use and installation of all types of sensors shall comply with the design technical requirements of the onboard hydrogen system. The recommended technical indices of all types of sensors should meet the requirements of Appendix B.

4.1.5 The monitoring system shall be equipped with a power failure protection device or other measures to support the normal operation of the monitoring system for no less than 12 hours when the vehicle is not started. It is advisable to select a vehicle power supply or an external power supply according to actual conditions.

4.2 Hydrogen concentration monitoring alarm

4.2.1 The monitoring system shall have an online monitoring alarm function for the hydrogen concentration of the onboard hydrogen system. The hydrogen concentration monitoring alarm shall meet the following requirements:

a) The hydrogen leakage status of the onboard hydrogen system is monitored in real time by a hydrogen concentration sensor, both when the vehicle is started and when it is not started.

b) An alarm will sound when the hydrogen concentration monitoring data exceeds the set alarm threshold.

c) Alarms shall be graded based on different risk level thresholds or the severity of exceeding the thresholds. At least two risk levels shall be set for hydrogen leakage alarms, and the judgment thresholds for each level shall be adjustable. The relationship between hydrogen concentration thresholds and warning signal levels is determined by the manufacturer based on vehicle type, operating environment, and requirements.

4.2.2 The hydrogen concentration sensor connected to the monitoring system should preferably be an existing sensor and shall meet the technical requirements of 4.1.2.1 in GB/T 24549-2020.

4.2.3 The missing alarm rate of the hydrogen concentration monitoring abnormality of the monitoring system shall be tested according to the test method specified in 5.2.2. The missing alarm rate of the hydrogen concentration monitoring abnormality shall not exceed 1%.

4.2.4 The false alarm rate of the hydrogen concentration monitoring abnormality of the monitoring system shall be tested according to the test method specified in 5.2.3. The false alarm rate of the hydrogen concentration monitoring abnormality shall not exceed 3%.

4.3 Pressure monitoring alarm

4.3.1 The monitoring system shall have the function of online monitoring of hydrogen pressure in the onboard hydrogen system, and the hydrogen pressure monitoring alarm shall at least meet the following requirements:

a) The hydrogen pressure state of the onboard hydrogen system can be monitored in real time through the pressure sensor when the vehicle is started and not started.

b) When the hydrogen pressure monitoring data reaches the set alarm threshold, a low-pressure or overpressure risk alarm will be issued.

c) Alarms shall be graded according to different hazard level thresholds or the severity of exceeding the set thresholds. Pressure alarms (including low-pressure alarms and over-pressure alarms) shall have at least two risk levels, and the judgment thresholds for each level shall be adjustable. The relationship between pressure thresholds and warning signal levels is determined by the manufacturer based on vehicle type, operating environment, and requirements.

4.3.2 The arrangement of pressure sensors shall meet the following requirements:

a) Pressure sensors for high-pressure monitoring and low-pressure monitoring shall be installed, respectively, according to different pressure levels.

b) The high-pressure sensor should be placed in a suitable position near the hydrogen storage cylinder opening, and the low-pressure sensor should be placed in a suitable position after the pressure regulator and near the fuel cell system.

c) Mechanical or electromagnetic interference shall be avoided, and ease of installation and maintenance shall be considered.

4.3.3 The missing alarm rate of the hydrogen pressure abnormality of the monitoring system shall be tested according to the test method specified in 5.3.2. The missing alarm rate of the pressure monitoring abnormality shall not exceed 3%.

4.3.4 The false alarm rate of the hydrogen pressure abnormality of the monitoring system shall be tested according to the test method specified in 5.3.3. The false alarm rate of the pressure monitoring abnormality shall not exceed 5%.

4.4 Temperature monitoring alarm

4.4.1 The monitoring system shall have the function of online monitoring of hydrogen temperature in the onboard hydrogen system, and the hydrogen temperature monitoring alarm shall at least meet the following requirements:

a) The temperature of the hydrogen in the onboard hydrogen system can be monitored in real time by a set temperature sensor, whether the vehicle is started or not started.

b) When the hydrogen temperature monitoring data reaches the set alarm threshold, a low temperature or over-temperature risk alarm will be issued.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download QC/T 1266-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
25 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

QC/T 1266-2025

$433.00