QB/T 4975-2016Safety technical specifications for using flammable refrigerants in household and similar room air conditioner industry (English PDF)
使用可燃性制冷剂生产家用和类似用途房间空调器安全技术规范
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for QB/T 4975-2016 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of PRC
Level / Type
National · Recommended
Issue date
October 22, 2018
Implementation date
April 1, 2019
Scope
QB/T 4975-2016 is the English-translated version of 使用可燃性制冷剂生产家用和类似用途房间空调器安全技术规范.
QB/T 4975-2016 — This standard specifies the methods for the determination of hexavalent chromium in cosmetics, by diphenylcarbazide spectrophotometry and ion chromatography- inductively coupled plasma mass spectrometry.
This standard applies to the determination of hexavalent chromium in cosmetics. When the sample weight is 2 g, the detection limit of diphenylcarbazide spectrophotometry is
Found what you need?
Document preview — QB/T 4975-2016
National Standard of the People's Republic of China
- ICS
- 71.100.70
Issued by: Ministry of Industry and Information Technology of PRC
Contents
- Foreword...3
- Introduction...4
- 1 Scope...5
- 2 Normative references...5
- 3 Method 1 -- Diphenylcarbazide spectrophotometry...5
- 4 Method 2 -- Ion chromatography-inductively coupled plasma mass spectrometry...8
- Appendix A (Informative) Reference conditions of instrument...12
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by China National Light Industry Federation.
This standard shall be under the jurisdiction of the National Standardization Technical
Committee of Flavor, Flavor and Cosmetics (SAC/TC 257).
Drafting organizations of this standard. Dalian Institute of Product Quality Inspection
(National Center for Quality Supervision and Inspection of Daily Chemical Products),
Dalian Food Inspection Institute, Shanghai Institute of Daily Chemical Industry
(National Center for Quality Supervision and Inspection of Flavor and Cosmetics).
1 Scope
This standard specifies the methods for the determination of hexavalent chromium in
cosmetics, by diphenylcarbazide spectrophotometry and ion chromatography-
inductively coupled plasma mass spectrometry.
This standard applies to the determination of hexavalent chromium in cosmetics. When
the sample weight is 2 g, the detection limit of diphenylcarbazide spectrophotometry is
0.25 mg/kg, the quantification limit is 0.83 mg/kg; the detection limit of ion
chromatography-inductively coupled plasma mass spectrometry is 0.010 mg/kg, the
quantification limit is 0.033 mg/kg.
2 Normative references
The following documents are essential to the application of this document. For the dated
documents, only the versions with the dates indicated are applicable to this document;
for the undated documents, only the latest version (including all the amendments) is
applicable to this standard.
GB/T 6682 Water for analytical laboratory use - Specification and test methods
3 Method 1 -- Diphenylcarbazide spectrophotometry
3.1 Principle
After the sample is extracted by the alkaline leaching solution, the hexavalent
chromium in the leaching solution reacted with diphenylcarbazide in an acidic solution,
to form a purple-red complex, which was determined by spectrophotometry, at a
wavelength of 540 nm.
3.2 Reagents
Unless otherwise specified, the reagents are of analytical grade. The water is the first
grade water, which is specified in GB/T 6682.
3.3 Instruments
3.4 Analytical procedures
3.5 Result calculation
Calculate the hexavalent chromium, X, in the specimen, according to formula (1).
3.6 Recovery and precision
When the standard addition concentration is in the range of 0.5 mg/L ~ 10.0 mg/L, the
recoveries are in the range of 88.4% ~ 102.9%, the precisions are in the range of 1.9%
~ 7.1%.
3.7 Tolerance
The absolute difference, between the results of two independent determinations, which
are obtained under repeatability conditions, shall not exceed 10% of the arithmetic
mean.
4 Method 2 -- Ion chromatography-inductively coupled plasma mass spectrometry
4.1 Principle
After the samples are extracted with alkaline leaching solution, the leaching solution is
determined by ion chromatography-inductively coupled plasma mass spectrometry,
AND quantified by external standard method.
4.2 Reagents
Unless otherwise specified, the reagents are of analytical grade. The water is the first
grade water, which is specified in GB/T 6682.
4.3 Instruments and equipment
4.3.1 Ion chromatography-inductively coupled plasma mass spectrometer.
4.3.2 Ultrasonic generator. Constant temperature (60 ± 1) °C.
4.3.3 Analytical balance. Sensitivity 0.0001 g.
4.3.4 Graduated centrifuge tube (polyethylene or polypropylene). Specification 50 mL.
4.4 Analytical procedures
4.4.1 Pre-treatment of sample
Accurately weigh (0.5 g ~ 2 g, accurate to 0.0001 g) of the sample, into a 50 mL
graduated centrifuge tube. Add 20.0 mL of extract (4.2.8) and 0.5 mL of buffer (4.2.9).
Completely submerge the sample in the extract. Shake well. Carry out ultrasonic
extraction, at 60 °C for 20 min. Take it out. After cooling to room temperature, use
water to make the volume to 25.0 mL. Add 2.0 g of activated carbon powder. Shake
well. Use filter paper to filter it. Discard the first 1 mL of filtrate. Collect the filtrate.
Use microporous filter membrane (4.2.13) to filter the collected filtrate. Prepare for
determination. Meanwhile do a reagent blank test.
4.4.3 Determination
The instrument is tuned and set, to measure the standard curve solution, reagent blank
solution, sample solution in sequence. See Appendix A, for instrument reference
conditions.
4.6 Recovery and precision
When the standard concentration is in the range of 0.10 mg/kg ~ 10 mg/kg, the recovery
rate is 86.0% ~ 103.7% AND the precision is in the range of 1.1% ~ 8.1%.
4.7 Tolerance
The absolute difference, between the results of two independent determinations, which
are obtained under repeatability conditions, is not more than 10 % of the arithmetic
mean.
Appendix A
(Informative)
Reference conditions of instrument
A.1 Ion chromatography conditions
The ion chromatography conditions are as follows.
A.2 Inductively coupled plasma mass spectrometry conditions
Inductively coupled plasma mass spectrometry conditions are as follows.
Appendix B
(Informative)
Ion chromatography-mass spectrograms of standard solutions and samples
See Figure B.1 and Figure B.2, for the ion chromatogram-mass spectrum of the standard
solution and sample.
QB/T 5291-2018
LIGHT INDUSTRY STANDARD OF
THE PEOPLE'S REPUBLIC OF CHINA
ICS 71.100.70
Classification No.. Y42
Filing No.. 65903-2018
Determination of hexavalent chromium in cosmetics
Issued on. OCTOBER 22, 2018
Implemented on. APRIL 01, 2019
Issued by. Ministry of Industry and Information Technology of PRC
Table of Contents
Foreword... 3
Introduction... 4
1 Scope... 5
2 Normative references... 5
3 Method 1 -- Diphenylcarbazide spectrophotometry... 5
4 Method 2 -- Ion chromatography-inductively coupled plasma mass spectrometry... 8
Appendix A (Informative) Reference conditions of instrument... 12
Appendix B (Informative) Ion chromatography-mass spectrograms of standard
solutions and samples... 13
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by China National Light Industry Federation.
This standard shall be under the jurisdiction of the National Standardization Technical
Committee of Flavor, Flavor and Cosmetics (SAC/TC 257).
Drafting organizations of this standard. Dalian Institute of Product Quality Inspection
(National Center for Quality Supervision and Inspection of Daily Chemical Products),
Dalian Food Inspection Institute, Shanghai Institute of Daily Chemical Industry
(National Center for Quality Supervision and Inspection of Flavor and Cosmetics).
1 Scope
This standard specifies the methods for the determination of hexavalent chromium in
cosmetics, by diphenylcarbazide spectrophotometry and ion chromatography-
inductively coupled plasma mass spectrometry.
This standard applies to the determination of hexavalent chromium in cosmetics. When
the sample weight is 2 g, the detection limit of diphenylcarbazide spectrophotometry is
0.25 mg/kg, the quantification limit is 0.83 mg/kg; the detection limit of ion
chromatography-inductively coupled plasma mass spectrometry is 0.010 mg/kg, the
quantification limit is 0.033 mg/kg.
2 Normative references
The following documents are essential to the application of this document. For the dated
documents, only the versions with the dates indicated are applicable to this document;
for the undated documents, only the latest version (including all the amendments) is
applicable to this standard.
GB/T 6682 Water for analytical laboratory use - Specification and test methods
3 Method 1 -- Diphenylcarbazide spectrophotometry
3.1 Principle
After the sample is extracted by the alkaline leaching solution, the hexavalent
chromium in the leaching solution reacted with diphenylcarbazide in an acidic solution,
to form a purple-red complex, which was determined by spectrophotometry, at a
wavelength of 540 nm.
3.2 Reagents
Unless otherwise specified, the reagents are of analytical grade. The water is the first
grade water, which is specified in GB/T 6682.
3.3 Instruments
3.4 Analytical procedures
3.5 Result calculation
Calculate the hexavalent chromium, X, in the specimen, according to formula (1).
3.6 Recovery and precision
When the standard addition concentration is in the range of 0.5 mg/L ~ 10.0 mg/L, the
recoveries are in the range of 88.4% ~ 102.9%, the precisions are in the range of 1.9%
~ 7.1%.
3.7 Tolerance
The absolute difference, between the results of two independent determinations, which
are obtained under repeatability conditions, shall not exceed 10% of the arithmetic
mean.
4 Method 2 -- Ion chromatography-inductively coupled plasma mass spectrometry
4.1 Principle
After the samples are extracted with alkaline leaching solution, the leaching solution is
determined by ion chromatography-inductively coupled plasma mass spectrometry,
AND quantified by external standard method.
4.2 Reagents
Unless otherwise specified, the reagents are of analytical grade. The water is the first
grade water, which is specified in GB/T 6682.
4.3 Instruments and equipment
4.3.1 Ion chromatography-inductively coupled plasma mass spectrometer.
4.3.2 Ultrasonic generator. Constant temperature (60 ± 1) °C.
4.3.3 Analytical balance. Sensitivity 0.0001 g.
4.3.4 Graduated centrifuge tube (polyethylene or polypropylene). Specification 50 mL.
4.4 Analytical procedures
4.4.1 Pre-treatment of sample
Accurately weigh (0.5 g ~ 2 g, accurate to 0.0001 g) of the sample, into a 50 mL
graduated centrifuge tube. Add 20.0 mL of extract (4.2.8) and 0.5 mL of buffer (4.2.9).
Completely submerge the sample in the extract. Shake well. Carry out ultrasonic
extraction, at 60 °C for 20 min. Take it out. After cooling to room temperature, use
water to make the volume to 25.0 mL. Add 2.0 g of activated carbon powder. Shake
well. Use filter paper to filter it. Discard the first 1 mL of filtrate. Collect the filtrate.
Use microporous filter membrane (4.2.13) to filter the collected filtrate. Prepare for
determination. Meanwhile do a reagent blank test.
4.4.3 Determination
The instrument is tuned and set, to measure the standard curve solution, reagent blank
solution, sample solution in sequence. See Appendix A, for instrument reference
conditions.
4.6 Recovery and precision
When the standard concentration is in the range of 0.10 mg/kg ~ 10 mg/kg, the recovery
rate is 86.0% ~ 103.7% AND the precision is in the range of 1.1% ~ 8.1%.
4.7 Tolerance
The absolute difference, between the results of two independent determinations, which
are obtained under repeatability conditions, is not more than 10 % of the arithmetic
mean.
Appendix A
(Informative)
Reference conditions of instrument
A.1 Ion chromatography conditions
The ion chromatography conditions are as follows.
A.2 Inductively coupled plasma mass spectrometry conditions
Inductively coupled plasma mass spectrometry conditions are as follows.
Appendix B
(Informative)
Ion chromatography-mass spectrograms of standard solutions and samples
See Figure B.1 and Figure B.2, for the ion chromatogram-mass spectrum of the standard
solution and sample.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
Referenced standards
Normative references
How to Download QB/T 4975-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
QB/T 1117-2026 — Canned mixed fruits
QB/T 1118-2026 — Aspartic Acid
Secure payment via Stripe
Payments accepted
QB/T 4975-2016
$115.00