Valid

LY/T 3233-2020Guiding standard for formaldehyde release load capacity of wood floors for ground with heating system (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (5 pages)

Need quotation for your management?

Get a formal quotation for LY/T 3233-2020 in 30 minutes.

Issued by

State Forestry and Grassland Administration

Level / Type

National · Recommended

Issue date

December 29, 2020

Implementation date

June 1, 2021

Scope

LY/T 3233-2020 (Guiding standard for formaldehyde release load capacity of wood floors for ground with heating system) is available as an English-translated PDF.

LY/T 3233-2020 — This document specifies the terms and definitions of the specification for the formaldehyde release bearing capacity of wooden floors for floor heating, the calculation method of the indoor bearing capacity, and the inspection method.

Method, sampling method and inspection report. This document is applicable to the calculation and detection of the formaldehyde release bearing capacity of the wooden composite floor heating for interior decoration and decoration.

Found what you need?

Document preview — LY/T 3233-2020

National Standard of the People's Republic of China

ICS
79.080
Classification
B 70

Issued by: State Forestry and Grassland Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Calculation method of indoor carrying capacity
  • 4.1 Calculation of release rate
  • 4.2 Calculation of indoor carrying capacity
  • 5 Inspection method
  • 5.1 Instruments and equipment
  • 5.2 Test piece
  • 5.3 Test conditions
  • 5.4 Formaldehyde sample collection and analysis
  • 6 Sampling method
  • 7 Inspection report
  • 7.1 Inspection records
  • 7.2 Inspection report

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting. Appendix A of this document is an informative appendix.

1 Scope

This document specifies the terms and definitions of the specification for the formaldehyde release bearing capacity of wooden floors for floor heating, the calculation method of the indoor bearing capacity, and the inspection method.

Method, sampling method and inspection report.

This document is applicable to the calculation and detection of the formaldehyde release bearing capacity of the wooden composite floor heating for interior decoration and decoration.

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated reference documents, Only the version corresponding to that date is applicable to this document. For undated references, the latest version (including all amendments) is applicable to this file.

Note. For undated references, if the latest version contains the quoted content, then the last version containing the quoted content applies.

GB/T 17657-2013 Test method for physical and chemical properties of wood-based panels and facing wood-based panels GB 50325 Code for Indoor Environmental Pollution Control of Civil Construction Engineering LY/T 1612 1m3 climate chamber for formaldehyde emission detection LY/T 1700 Wooden floor for floor heating

3 Terms and definitions

The terms and definitions defined in LY/T 1700 and the following are applicable to this document.

Loading ratio

The ratio of the exposed surface area of the floor heating wooden floor to the volume of the floor heating environment.

Background concentration when the floor heating environment box is empty, the outlet concentration of the target compound in the box.

Indoor loading ratio the ratio of the exposed surface area of the indoor floor heating wooden floor to the indoor volume.

Emission rate

In unit time, the amount of formaldehyde released per unit area of wooden floor for floor heating.

Indoor load capacity in a certain space, under the premise of meeting the requirements of GB 50325 for the concentration of formaldehyde in the indoor air, the wooden floor for floor heating is used indoors.

Paving area.

Air exchange rate

The ratio of indoor ventilation volume per unit time to indoor volume.

4 Calculation method of indoor carrying capacity

4.1 Calculation of release rate

Where.

ER- the amount of formaldehyde released per unit area per unit time, in milligrams per square meter hour (mg/(m2﹒h)) the concentration of formaldehyde when the air formaldehyde concentration in the CS-climate reaches a steady state, in milligrams per cubic meter (mg/m3) N-air replacement rate per hour, the unit is times per hour (times/h) L-loading rate, the unit is square meter per cubic meter (m2/m3)

4.2 Calculation of indoor carrying capacity

The load-bearing capacity of the wooden floor for indoor floor heating shall be carried out according to formula (2).

D- Carrying capacity of wooden floor for floor heating, in square meters (m2) VE-The indoor volume occupied by the floor heating floor area, in cubic meters (m3) Cinfinity-The limit of formaldehyde concentration in indoor air that meets the requirements of GB 50325 (mg/m3) ER- the amount of formaldehyde released per unit area per unit time, in milligrams per square meter hour (mg/(m2﹒h)) 1h -1 hour

5 Inspection method

5.1 Instruments and equipment

5.1.1 Floor heating environment box

3 The technical parameters and requirements of the floor heating environment box should meet the requirements of LY/T 1612, and it is equipped with floor heating with a temperature range of 15°C~50°C Heating device, background concentration <=0.006mg/m3.See Appendix A for the principle of the floor heating environment box.

5.1.2 Other instruments

Others are in accordance with the provisions of 4.60 in GB/T 17657-2013.

5.2 Test piece

5.2.1 Specimen production

Take a number of wooden floor blocks for heating with an exposed area of not less than 1m2 as test pieces, remove the tongue and groove of the test piece, and keep the size of the test piece it is proved that when it is laid flat on the floor heating device, it will not be laid outside the floor heating device, and the exposed area of the test piece is 1m2 after edge sealing.

5.2.2 Balance treatment of test piece

According to the provisions of 4.60 in GB/T 17657-2013.

5.2.3 Edge banding of test piece

The four sides of the test piece with the tongue and groove removed and the back of the test piece are sealed with formaldehyde-free aluminum foil tape.

5.3 Test conditions

During the test, the following conditions were maintained in the floor heating environment.

5.4 Formaldehyde sample collection and analysis

The collection method and analysis method of formaldehyde are implemented according to 4.60 in GB/T 17657-2013, where the formaldehyde emission is accurate to 0.001mg/m

6 Sampling method

Randomly take samples with an exposed area of not less than 1 m2 from wooden floors for floor heating of the same location, category, and specification, and immediately Seal the sample with packaging materials that will not release or absorb formaldehyde and be tested.

a) When taking samples from the manufacturer, samples must be taken from the qualified products in the finished product warehouse of the manufacturer.

b) When the distribution company takes samples, the qualified products must be marked at the distribution site or in the distribution company's finished product warehouse to take samples.

c) When sampling samples at the construction or use site, they must be randomly selected from the same product at the same location.

7 Inspection report

7.1 Inspection records

The format is shown in Table 2.

7.2 Inspection report

7.2.1 The inspection report shall include the following information. product name, specifications, inspection standards, etc.

7.2.2 Test results and conclusions.

7.2.3 Abnormal situations and other problems that need to be explained during the inspection.

Appendix A

(Informative appendix) Installing a floor heating device in a 1 m3 climate box should ensure that the internal volume of the box meets the requirements of the relevant volume in LY/T 1612; floor heating the air temperature deviation at 150mm above the device is within ±0.5°C (controlled by the temperature sensor above the floor heating plate in the front view); floor heating the environmental box should meet the structure and technical parameters and technical requirements of LY/T 1612.

The main body of the floor heating device is welded by 304 steel plate, the heating plate is hollow, and it is divided into three layers, and each layer of the heating plate has a water inlet, the water outlet and the air vent, the heating plate is equipped with a sensor to control the water temperature; a sensor is also installed at 150mm above the heating plate to monitor the ground the temperature of the air above the board (Figure A.1 front view), the integrated combination of the floor heating device and the climate box, see Figure A.2, the right view; the wind directly behind the box A sensor is installed above the fan to control the temperature in the entire cabin to keep it at 23°C; the floor heating device is connected to the outside of the cabinet through a joint and a silicone hose.

The heating water tank is connected, a heating rod and a temperature sensor are installed in the lower part of the water tank, and the water is circulated between the heating device and the water tank through a circulating pump.

Figure A.1 Schematic diagram of floor heating device structure

Figure A.2 Schematic diagram of floor heating environment box structure

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.

Referenced standards

How to Download LY/T 3233-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
5 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

LY/T 3233-2020