Valid

LY/T 3154-2019Photocatalytic activated carbon for air purification (English PDF)

气相光催化净化用活性炭

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for LY/T 3154-2019 in 30 minutes.

Issued by

State Forestry and Grassland Administration

Level / Type

National · Recommended

Issue date

October 23, 2019

Implementation date

April 1, 2020

Scope

LY/T 3154-2019 is the English-translated version of 气相光催化净化用活性炭.

LY/T 3154-2019 — This standard specifies the technical requirements, test methods, inspection rules, marking, packaging, transportation, and storage of activated carbon for gas phase photocatalytic purification.

Save. This standard applies to granular activated carbon for gas-phase photocatalytic purification using wood and coal as raw materials.

Found what you need?

Document preview — LY/T 3154-2019

National Standard of the People's Republic of China

ICS
65.050
Classification
B 72

Issued by: State Forestry and Grassland Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Technical requirements
  • 5 Test method
  • 5.1 Moisture
  • 5.2 Intensity
  • 5.3 Iodine adsorption value
  • 5.4 Toluene degradation rate
  • 6 Inspection rules
  • 6.1 Batch unit
  • 6.2 Sampling rules
  • 6.3 Decision rules
  • 6.4 Expression of judgment results
  • 7 Marking, packaging, transportation, storage
  • 8 Test report

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed and managed by the National Forestry Chemical Product Standardization Technical Committee (SAC/TC558).

This standard was drafted. Forest Products Chemical Industry Research Institute, Chinese Academy of Forestry, Fujian Xinsen Carbon Industry Co., Ltd., Jiangsu Pu Shida Environmental Technology Co., Ltd.

1 Scope

This standard specifies the technical requirements, test methods, inspection rules, marking, packaging, transportation, and storage of activated carbon for gas phase photocatalytic purification.

Save.

This standard applies to granular activated carbon for gas-phase photocatalytic purification using wood and coal as raw materials.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 6678 General sampling rules for chemical products GB/T 6682 Analytical laboratory water specifications and test methods GB/T 12496.4 Test methods for wooden activated carbon-Determination of moisture content GB/T 12496.6 Test method for wooden activated carbon--Determination of strength GB/T 12496.8 Test method for wooden activated carbon-Determination of iodine adsorption value

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 The removal efficiency of toluene the ratio of the reduction of the toluene gas concentration before and after the test to the initial concentration is expressed in%.

3.2 The degradation efficiency of toluene the difference between the toluene removal rate when the UV lamp is on and off is expressed in%.

4 Technical requirements

4.1 Appearance is black granular, odorless.

4.2 The quality index of activated carbon for gas-phase photocatalytic purification shall meet the requirements of Table 1.

Table 1 Quality indicators

Project indicators

Moisture%, <= 10

Strength%, >= 90

Iodine adsorption value mg/g, >= 700 Toluene degradation rate%, >= 5

5 Test method

5.1 Moisture

Determine according to GB/T 12496.4.

5.2 Intensity

Determined according to GB/T 12496.6.

5.3 Iodine adsorption value

Determined according to GB/T 12496.8.

5.4 Toluene degradation rate

5.4.1 Method summary

The sample was placed in a photocatalytic reactor under specified conditions, and the toluene removal rate of the sample under the UV lamp on and off conditions was measured.

The difference between the two was used as the toluene degradation rate of the sample.

5.4.2 Reagents

5.4.2.1 Toluene (GB/T 684), analytical grade.

5.4.2.2 High purity nitrogen (GB/T 8979).

5.4.3 Instrument

5.4.3.1 Gas chromatograph, detection conditions. Agilent 19091J-413 HP-5 capillary chromatographic column (column length 30 m), hydrogen was used as for carrier gas, hydrogen flame detection. Detector temperature was.200 °C, column temperature was 150 °C, inlet temperature was 150 °C, split ratio was 20. 1, and injection was performed.

Volume 1 µL.

5.4.3.2 Photocatalytic reactor, 30 cm long, 20 cm wide and 50 cm high opaque box with four 20 W UV lamps (245 nm) with a quartz tube (10 mm diameter and 40 cm height) in the middle.

5.4.3.3 Gas mixing bottle, 500 ml.

5.4.3.4 Gas flowmeter, flow range 60 mL/min ~ 600 mL/min.

5.4.3.5 Analytical balance with a sensitivity of 0.1 mg.

5.4.4 Experimental device and installation instructions

The photocatalytic experimental device is shown in Figure 1. The instruments and equipment used in the experiment are connected, while ensuring the airtightness of the device. By adjusting nitrogen the flow meter ensures a stable and continuous gas flow throughout the system.

1. Air bottle; 2. Nitrogen bottle; 3. Flow meter; 4. Gas generation bottle; 5. Gas mixing bottle; 6. Ultraviolet lamp; 7. Quartz tube; 8. Gas chromatography; 9.

Exhaust absorption bottle

Figure 1 Experimental setup of gas phase photocatalysis

5.4.5 Test procedure
5.4.5.1 Sample preparation

The particle size of the sample is controlled within the range of 0.25 to 2 mm, and dried to a constant weight at 105 to 110 ° C, and placed in a dryer for later use.

5.4.5.2 Toluene gas preparation

Add the toluene solution from the inlet tube to a 500 mL gas wash bottle, approximately 10 cm in height in the bottle. Connect the porous gas wash bottle to the system, Put it in a constant temperature water bath (25 ± 1.0) °C vertically.

5.4.5.3 Toluene standard curve drawing

At (25 ± 1.0) °C, take 25 µL of toluene in a 500mL reagent bottle, configure the volume concentration to be 50 × 10-6, and then take the volume concentration of the gas is gradually diluted to obtain other target concentrations of gas, and a standard curve is drawn. This standard line is used as toluene Used for gas detection marking.

5.4.5.4 Operation process

Bring the toluene gas into the buffer bottle with 500 mL/min nitrogen as the carrier gas, and mix it with 500 mL/min clean air to adjust the N2 flow the initial toluene concentration was kept at 2.5 x 10-5. The mixed gas enters the photocatalytic reactor. Gas chromatograph is used for gas detection, the exhaust gas is exhausted after being absorbed.

With the UV lamp turned off, accurately weigh 2.0 g (accurate to 0.0001 g) of the sample and place it in the photocatalytic reactor.

Phase chromatograph detected the toluene concentration at the gas port;

Take another sample and repeat the above steps with the UV lamp on.

5.4.6 Result calculation

The toluene removal rate and toluene degradation rate are calculated according to formulas (1) and (2).

, 100% t

2 1X XX= - (2)

In the formula.

X-toluene degradation rate,%;

X1-Toluene removal rate with UV lamp off,%;

X2-toluene removal rate when the UV lamp is on,%;

C0-toluene initial concentration;

Ct-60 min toluene concentration at the air outlet.

5.4.7 Representation of results

The toluene degradation rate is the arithmetic mean of two parallel experiments.

5.4.8 Allowable error

The relative error of the two parallel determinations of the degradation rate of toluene shall not exceed 5%.

6 Inspection rules

6.1 Batch unit

The mass of each batch does not exceed 1 kg.

6.2 Sampling rules

6.2.1 Number of samples per batch. implemented according to GB/T 6678. The rules for selecting the number of sampling units are shown in Table 2.

6.2.2 Sample size. The sample size of each batch is not less than 100 g.

Mix the extracted samples thoroughly, shrink the sample by quartering method, select 100 g and put them into two clean and dry glasses with grinding plugs in the bottle, a label is attached on the bottle, indicating the manufacturer's name, product model, grade, batch number, sampling date, one bottle for inspection, and one bottle for storage for inspection.

Table 2 Number of sampling units

The minimum number of units for the unit of the overall material 1 ~ 10 11 ~ 49 50 ~ 64 65 ~ 81 82 ~ 101 102 ~ 125 126 ~ 151 152 ~ 181 182 ~ 216 217 ~ 254 255 ~ 296 297 ~ 343 344 ~ 394 all units 395 ~ 450 451 ~ 512

6.2.3 The sampler shall be clean and rust-free, and inserted three-quarters of its depth along the diagonal of the package.

6.3 Decision rules

There is an unqualified index requirement in the test results. The sample should be re-selected from the double-volume packaging for testing, and the re-test results are still not consistent.

If the product is qualified, the products in this batch are judged as non-conforming products.

6.4 Expression of judgment results

According to the test results, the quality indicators in Table 1 are compared to determine whether the sample is a qualified product. The result is expressed as follows.

In the case of unopened use, it is a qualified/non-qualified product.

7 Marking, packaging, transportation, storage

7.1 Marking. The product packaging should have the manufacturer's name, product name, trademark, product model and mark, manufacturing date or production batch number, warranty Quality period, main parameters of the product, net weight of the product.

7.2 Packaging. The inner layer should be sealed from moisture and added with appropriate outer packaging.

7.3 Transportation. Avoid rain during transportation, and pay attention to light loading and unloading.

7.4 Storage. Store in a cool, ventilated and dry place.

8 Test report

The test report should include the following.

1) Sample number;

2) the standards used;

3) the method used;

4) Test items;

5) Test results;

6) Testing personnel;

7) Audit staff;

8) Test date.

Appendix A

(Informative appendix) Chromatographic analysis of toluene 0 2 4 6 8 10 12 14 1000pA min 2.427

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download LY/T 3154-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

LY/T 3154-2019

$150.00