Scope

JTG D60-2015 is the English-translated version of 公路桥涵设计通用规范.

JTG D60-2015 is the Chinese standard "General Specifications for Design of Highway Bridges and Culverts". Its scope clause reads: 1.0.1 This specification is formulated to standardize the design of highway bridges and culverts in accordance with the principles of safety, durability, applicability, environmental protection, economy and aesthetics.

1.0.2 This specification is applicable to the design of newly built and reconstructed highway bridges and culverts of all grades. 1.0.3 The design reference period of highway bridge and culvert structures is 100 years.

1.0.4 The design working life of the main structures and replaceable components of highway bridges and culverts shall not be less than that specified in Table 1.0.4.

Table 1.0.4 Design working life of bridges and culverts (years) Columns: highway grade | main structure: super-large bridges and large bridges | main structure: medium bridges | main structure: small bridges and culverts | replaceable components: stay cables, suspenders, tie rods, etc. | replaceable components: railings, expansion devices, bearings, etc. Expressway, Class I highway | 100 | 100 | 50 | 20 | 15 Class II highway, Class III highway | 100 | 50 | 30 | 20 | 15 Class IV highway | 100 | 50 | 30 | 20 | 15 1.0.5 The classification of super-large, large, medium and small bridges and culverts by single-span length or total multi-span length is given in Table 1.0.5.

Table 1.0.5 Classification of bridges and culverts Columns: classification | total multi-span length L (m) | single-span length LK (m) Super-large bridge | L > 1 000 | LK > 150 Large bridge | 100 <= L <= 1 000 | 40 <= LK <= 150 Medium bridge | 30 < L < 100 | 20 <= LK < 40 Small bridge | 8 <= L <= 30 | 5 <= LK < 20 Culvert | - | LK < 5 Note 1: The single-span length refers to the standard span.

Note 2: The total multi-span length of girder bridges and slab bridges is the sum of the standard spans of the multiple sp

Found what you need?

Document preview — JTG D60-2015

National Standard of the People's Republic of China

Replacing
JTG D60-2004

Issued by: MOT

Contents

  • 1 General provisions
  • 2 Terms and symbols
  • 2.1 Terms
  • 2.2 Symbols
  • 3 Design requirements
  • 3.1 General requirements
  • 3.2 Layout of bridges and culverts
  • 3.3 Waterway openings of bridges and culverts
  • 3.4 Clearances of bridges and culverts
  • 3.5 Alignment on bridges and bridge approaches
  • 3.6 Detailing requirements
  • 3.7 Deck pavement, waterproofing and drainage
  • 3.8 Maintenance and other ancillary facilities
  • 4 Actions
  • 4.1 Classification, representative values and combinations of actions
  • 4.2 Permanent actions
  • 4.3 Variable actions
  • 4.4 Accidental actions
  • 4.5 Seismic actions
  • Appendix A National climatic zoning map
  • Explanation of wording in this specification
  • Attachment: Explanation of provisions of General Specifications for Design of Highway Bridges and Culverts (JTG D60-2015)
  • 1 General provisions
  • 3 Design requirements
  • 4 Actions

Foreword

In accordance with the requirements of the "Notice on Issuing the 2009 Plan of Highway Engineering Standard Formulation and Revision Projects" (Ting Gonglu Zi [2009] No. 190) of the Ministry of Transport, CCCC Highway Consultants Co., Ltd., as the chief development organization, undertook the revision of the "General Specifications for Design of Highway Bridges and Culverts" (JTG D60-2004).

This specification is a comprehensive revision of the former "General Specifications for Design of Highway Bridges and Culverts" (JTG D60-2004). After approval it is issued and implemented as the "General Specifications for Design of Highway Bridges and Culverts" (JTG D60-2015).

During the revision, the revision group carried out a large amount of scientific research work, absorbed the research results and practical engineering design experience of other domestic organizations, referred to and drew on advanced international standards and specifications, and compared and coordinated this specification with related domestic specifications. After the initial draft of the provisions was completed, the opinions of relevant organizations and individuals engaged in design, construction, project development and administration were widely solicited in various ways, and the text was finalized after repeated discussion and modification.

This specification consists of 4 chapters and 1 appendix. The main chapters are: 1 General provisions; 2 Terms and symbols; 3 Design requirements; 4 Actions.

The main contents of this revision include: requirements on the overall design of bridges and culverts have been supplemented; provisions on the design working life of bridges and culverts, traffic safety, environmental protection, durability, structural monitoring of bridges and risk assessment have been added; design requirements for maintenance facilities of bridges and culverts have been added; the provisions on the classification and calculation methods of combinations of actions and on vehicle load standards have been adjusted; provisions on characteristic values of vehicle fatigue loads, etc. have been added; provisions on the seismic design situation have been supplemented.

All relevant organizations are requested to send any problems and comments found during implementation to the routine management group of this specification (address: CCCC Highway Consultants Co., Ltd., Room 407, Block B, Desheng International Center, No. 83 Deshengmenwai Street, Beijing; postcode: 100088; fax: 010-82017041) for reference in future revision.

Chief development organization: CCCC Highway Consultants Co., Ltd.

Participating development organizations: Tongji University; Chongqing Jiaotong University

1 General provisions

1.0.1 This specification is formulated to standardize the design of highway bridges and culverts in accordance with the principles of safety, durability, applicability, environmental protection, economy and aesthetics.

1.0.2 This specification is applicable to the design of newly built and reconstructed highway bridges and culverts of all grades.

1.0.3 The design reference period of highway bridge and culvert structures is 100 years.

1.0.4 The design working life of the main structures and replaceable components of highway bridges and culverts shall not be less than that specified in Table 1.0.4.

Table 1.0.4 Design working life of bridges and culverts (years)

Columns: highway grade | main structure: super-large bridges and large bridges | main structure: medium bridges | main structure: small bridges and culverts | replaceable components: stay cables, suspenders, tie rods, etc. | replaceable components: railings, expansion devices, bearings, etc.

Expressway, Class I highway | 100 | 100 | 50 | 20 | 15

Class II highway, Class III highway | 100 | 50 | 30 | 20 | 15

Class IV highway | 100 | 50 | 30 | 20 | 15

1.0.5 The classification of super-large, large, medium and small bridges and culverts by single-span length or total multi-span length is given in Table 1.0.5.

Table 1.0.5 Classification of bridges and culverts

Columns: classification | total multi-span length L (m) | single-span length LK (m)

Super-large bridge | L > 1 000 | LK > 150

Large bridge | 100 <= L <= 1 000 | 40 <= LK <= 150

Medium bridge | 30 < L < 100 | 20 <= LK < 40

Small bridge | 8 <= L <= 30 | 5 <= LK < 20

Culvert | - | LK < 5

Note 1: The single-span length refers to the standard span.

Note 2: The total multi-span length of girder bridges and slab bridges is the sum of the standard spans of the multiple spans; for arch bridges it is the distance between the springing lines inside the abutments at both ends; for bridges of other types it is the length of the carriageway of the deck system.

Note 3: Pipe culverts and box culverts are all called culverts, regardless of the pipe diameter or span and the number of spans.

Note 4: Standard span: for girder bridges and slab bridges, the distance between the centre lines of two piers or between the centre line of a pier and the front edge of the abutment back wall; for arch bridges and culverts, the clear span.

1.0.6 Highway bridges and culverts shall be designed for disaster mitigation and prevention, such as resistance to wind, earthquake and collision.

1.0.7 The design of highway bridges and culverts shall meet the relevant requirements of environmental protection and resource conservation.

1.0.8 The design of highway bridges and culverts shall comply not only with this specification but also with the current relevant national and industry standards.

2 Terms and symbols

2.1 Terms

2.1.1 design reference period

Time parameter selected for determining the values of variable actions, etc.

2.1.2 design working/service life

Period during which, under the conditions of normal design, normal construction, normal use and normal maintenance, a bridge or culvert structure or structural member can be used for its intended purpose without major repair or replacement.

2.1.3 limit states

When the whole structure or a part of the structure exceeds a certain specified state, it can no longer satisfy a certain functional requirement specified in the design; this specified state is the limit state for that function.

2.1.4 ultimate limit states

States corresponding to the structure or structural member reaching its maximum load-bearing capacity or a deformation unsuitable for continued load-bearing.

2.1.5 serviceability limit states

States corresponding to the structure or structural member reaching a specified limit value for normal use or durability.

2.1.6 design situations

Set of design conditions representing the actual situation in a certain period of time; the design shall ensure that the structure does not exceed the relevant limit states under that set of conditions.

2.1.7 structural durability

Ability of the structure and its members to maintain their safety and serviceability within the design working life under the environmental actions and the maintenance and use conditions determined in the design.

2.1.8 action

Concentrated or distributed forces applied to the structure (direct actions, also called loads) and causes of imposed or restrained deformation of the structure (indirect actions).

2.1.9 permanent action

Action that is always present during the design reference period and whose variation in magnitude is negligible compared with its mean value, or whose variation is monotonic and tends to a limit value.

2.1.10 variable action

Action whose magnitude varies with time during the design reference period and whose variation is not negligible compared with its mean value.

2.1.11 accidental action

Action that does not necessarily occur during the design reference period, but whose magnitude is very large and whose duration is very short once it occurs.

2.1.12 characteristic value of an action

Principal representative value of an action, which may be determined from statistics of observed data, natural limits of the action or engineering experience.

2.1.13 accompanying value of a variable action

Value of a variable action accompanying the leading action in a combination of actions. It may be the combination value, the frequent value or the quasi-permanent value.

2.1.14 representative value of an action

Value of an action used in limit state design. It may be the characteristic value of an action or the accompanying value of a variable action.

2.1.15 design value of an action

Product of the representative value of an action and the partial factor for the action.

2.1.16 combination value of a variable action

Value of an action for which the probability of exceedance of the action effect after combination approximates the probability of exceedance of the effect of its characteristic value when the action occurs alone; or the value of an action that gives the structure a specified reliability index after combination. It may be expressed by reducing the characteristic value of the action by a combination value factor.

2.1.17 frequent value of a variable action

Value of an action whose total time of exceedance during the design reference period is a small proportion of the design reference period, or whose frequency of exceedance is limited to a specified frequency. It may be expressed by reducing the characteristic value of the action by a frequent value factor.

2.1.18 quasi-permanent value of a variable action

Value of an action whose total time of exceedance during the design reference period is a large proportion of the design reference period. It may be expressed by reducing the characteristic value of the action by a quasi-permanent value factor.

2.1.19 effect of action

Response of the structure or structural member caused by actions.

2.1.20 combination of actions (load combination)

Set of design values of actions adopted to verify the structural reliability for a certain limit state under the simultaneous influence of different actions.

2.1.21 fundamental combination of actions

Combination of the design values of permanent actions and the design values of variable actions in ultimate limit state design.

2.1.22 accidental combination of actions

Combination of the characteristic values of permanent actions, certain representative values of variable actions and the design value of one accidental action in ultimate limit state design.

2.1.23 frequent combination of actions

Combination of the characteristic values of permanent actions, the frequent value of the leading variable action and the quasi-permanent values of the accompanying variable actions in serviceability limit state design.

2.1.24 quasi-permanent combination of actions

Combination of the characteristic values of permanent actions and the quasi-permanent values of variable actions in serviceability limit state design.

2.1.25 partial safety factor

Factor adopted in the design expressions to ensure that the designed structure has the specified reliability when the probabilistic limit state design method is used. It is divided into two types: partial factors for actions and partial factors for resistance.

2.1.26 factor for importance of structure

Partial factor adopted for structures of different safety classes so that they have the specified reliability.

Remaining clauses in the full document

  • 2.2 Symbols
  • 3 Design requirements
  • 3.1 General requirements
  • 3.2 Layout of bridges and culverts
  • 3.3 Waterway openings of bridges and culverts
  • 3.4 Clearances of bridges and culverts
  • 3.5 Alignment on bridges and bridge approaches
  • 3.6 Detailing requirements
  • 3.7 Deck pavement, waterproofing and drainage
  • 3.8 Maintenance and other ancillary facilities
  • 4 Actions
  • Appendix A National climatic zoning map
  • Explanation of wording in this specification
  • Attachment: Explanation of provisions

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 120 pages — is available in the English PDF.

How to Download JTG D60-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
120 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JTG D60-2015

$505.00