JJG 991-2017Audiometric Equipment--Instruments for the Measurement of Aural Acoustic Impedance/Admittance (English PDF)
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for JJG 991-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
November 20, 2017
Implementation date
May 20, 2018
Scope
JJG 991-2017 (Audiometric Equipment--Instruments for the Measurement of Aural Acoustic Impedance/Admittance) is available as an English-translated PDF.
JJG 991-2017 — This standard applies to the first verification, subsequent verification and in-use inspection of otoacoustic impedance/admittance measurement instruments.
Found what you need?
Document preview — JJG 991-2017
National Standard of the People's Republic of China
- ICS
- 17.140
- Classification
- A 59
- Replacing
- JJG 991-2004
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and units of measure (2)
- 3.1 Acoustic impedance (2)
- 3.2 Acoustic admittance (2)
- 3.3 Equivalent volume (2)
- 3.4 Relative pressure in the external auditory canal (2)
- 3.5 Probes (2)
- 3.6 Earplugs (2)
- 3.7 Probe Signal (3)
- 3.8 Probe Ears (3)
- 3.9 Measurement Plane (3)
- 3.10 Tympanometry (3)
- 3.11 Measuring tympanometry (3)
- 3.12 Ear canal-compensated tympanometry (3)
- 3.13 Tympanogram (3)
- 3.14 Acoustic Reflection (3)
- 3.15 Ipsilateral reflection (3)
- 3.16 Contralateral Sound Reflection (3)
- 4 Overview (3)
- 5 Metrological performance requirements (4)
- 5.1 Human Otoacoustic Impedance/Admittance Measurement System (4)
- 5.2 Pressure System (4)
- 5.3 Acoustic Reflection Stimulation System (5)
- 6 General technical requirements (6)
- 6.1 Appearance (6)
- 6.2 Signs (6)
- 6.3 Operating instructions (6)
- 7 Measuring Instruments Control (7)
- 7.1 Verification conditions (7)
- 7.2 Verification Projects (7)
- 7.3 Verification Methods (8)
- 7.4 Processing of verification results (12)
- 7.5 Certification Period (12)
- Appendix A Insertion Headphones Pure-tone Reference Equivalent Sensing Sound Pressure Level (13)
- Appendix B Loudspeaker Standard Reference Echo Threshold Sound Pressure Level (14)
- Appendix C Internal Page Format of Notification of Verification Certificate and Verification Results (16)
1 Scope (1)
2 References (1)
3 Terms and units of measure (2)
3.1 Acoustic impedance (2)
3.2 Acoustic admittance (2)
3.3 Equivalent volume (2)
3.4 Relative pressure in the external auditory canal (2)
3.5 Probes (2)
3.6 Earplugs (2)
3.7 Probe Signal (3)
3.8 Probe Ears (3)
3.9 Measurement Plane (3)
3.10 Tympanometry (3)
3.11 Measuring tympanometry (3)
3.12 Ear canal-compensated tympanometry (3)
3.13 Tympanogram (3)
3.14 Acoustic Reflection (3)
3.15 Ipsilateral reflection (3)
3.16 Contralateral Sound Reflection (3)
4 Overview (3)
5 Metrological performance requirements (4)
5.1 Human Otoacoustic Impedance/Admittance Measurement System (4)
5.2 Pressure System (4)
5.3 Acoustic Reflection Stimulation System (5)
6 General technical requirements (6)
6.1 Appearance (6)
6.2 Signs (6)
6.3 Operating instructions (6)
7 Measuring Instruments Control (7)
7.1 Verification conditions (7)
7.2 Verification Projects (7)
7.3 Verification Methods (8)
7.4 Processing of verification results (12)
7.5 Certification Period (12)
Appendix A Insertion Headphones Pure-tone Reference Equivalent Sensing Sound Pressure Level (13)
Appendix B Loudspeaker Standard Reference Echo Threshold Sound Pressure Level (14)
Appendix C Internal Page Format of Notification of Verification Certificate and Verification Results (16)
Introduction
This code is based on the requirements and format of the JJF1002-2010 "Rules for the preparation of national metrological verification regulations".
According to JJF1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" to assess the uncertainty of the measurement results.
This procedure mainly refers to IEC 60645-5:2004 "Electroacoustic audiometry equipment - Part 5. Otoacoustic impedance/conductivity Nanometric Instruments (Electroacoustics-Audiometricequipment-Part 5. Instrumentsforthe Measurementofauralacousticimpedance/admittance) for JJG 991-2004 Impedance Hearing the "testing procedures" are revised. Compared with JJG 991-2004, the main technical changes except editorial modification are as follows.
--- In keeping with IEC 60645-5:2004 and GB/T 15953-1995, change the name of this regulation it is the verification procedure for the "acoustic impedance/admittance measurement instrument for audiometry equipment".
--- According to IEC 60645-5:2004 and related standards, the related terms in the original regulations have been adjusted, such as Added tympanometry, and other concepts.
--- According to IEC 60645-5:2004 and related standards, the measurement performance requirements in the original regulations were revised Changed to meet the requirements of the new standard, and the technical requirements of the amendment mainly include. probe tone and acoustic reflection stimulation pure tone stimulation the maximum allowable error of the signal frequency and total harmonic distortion, pressure indication error and so on.
--- In the "Accreditation Project", the first test, follow-up test and in-use check items are distinguished.
---In the "measurement standards and major ancillary equipment", the "measurement amplifier" and "bandpass filter" replacement Into an "acoustic analyzer"; distinguishes and describes four possible ear simulators and acoustic couplers;
The requirements of IEC 60645-5:2004 increase the "standard volume chamber" equipment and its technical requirements.
--- According to the requirements of JJF1002-2010 to re-revise the verification certificate/verification results notice page format.
The issuance of previous versions of this procedure is.
---JJG 991-2004.
Auditory Equipment Otoacoustic Impedance/Admittance Measuring Instrument Verification Procedures
1 Scope
This procedure is applicable to the first verification, subsequent verification and in-service inspection of otoacoustic impedance/admittance measurement instruments.
2 references
This procedure refers to the following documents.
JJG 388-2012 Audiometric Instrument Pure Tone Audiometer JJF1001-2011 Universal Measurement Terms and Definitions JJF1034-2005 Acoustic Measurement Terms Terms and Definitions GB/T 3102.7 Acoustic quantities and units GB/T 3947 Acoustic Terms GB/T 4854.1-2004 Reference zero for acoustic calibration audiometry equipment. Part 1. Pure ear headphones Sound Reference Equivalent Threshold Sound Pressure Level GB/T 15953-1995 Otoacoustic Impedance/Admittance Measuring Instrument GB/T 16402-1996 Acoustic Insertion Headphones Pure Tone Reference Equivalent Threshold Sound Pressure Level GB/T 25498.3 Electroacoustic head simulator and ear simulator Part 3. Calibrated pressure ear Machine acoustic coupler IEC 60318-1 Electroacoustic head and ear simulators. Part 1. Calibration of earphones and earmuffs Electroacoustics-Simulatorsofhumanheadandear-Part 1: Earsimu-Latorforthemeasurementofsupra-auralandcircumauralearphones) IEC 60318-4 Electroacoustic head and ear simulators. Part 4. Earphone measurements using earplugs coupled to the human ear Quantity Accelerators-Simulatorsofhumanheadandear-Part 4: Occlu-Ded-earsimulatorforthemeasurementofearphonescoupledtoearbymeansofear Inserts) IEC 60318-5 Electroacoustic head and ear simulators. Part 5. Measurement of earbud hearing aids and earphones 2cm3 Coupler (Electroacoustics-Simulatorsofhumanheadandear-Part 5.2cm3 Couplerforthemeasurementofhearingaidsandearphonescoupledtheearbymeans Ofearinserts) IEC 60645-5:2004 Electroacoustic audiometry equipment - Part 5. Otoacoustic impedance/admittance measuring instruments (Electroacoustics-Audiometricequipment-Part 5. Instrumentsforthemeasurement Ofauralacousticimpedance/admittance) for dated references, only the dated version applies to this procedure; any undated references the latest version (including all amendments) is applicable to this procedure.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
How to Download JJG 991-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 991-2017
$355.00