JJG 960-2012Verification Regulation of Level Verification System (English PDF)
This is a limited preview
Buy now to download the full PDF (14 pages)
Need quotation for your management?
Get a formal quotation for JJG 960-2012 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJG 960-2012 (Verification Regulation of Level Verification System) is available as an English-translated PDF.
JJG 960-2012 — This standard applies to all kinds of water level verification device initial verification, testing and use of follow-up inspection.
Found what you need?
Document preview — JJG 960-2012
National Standard of the People's Republic of China
- ICS
- 17.040
- Classification
- A 52
- Replacing
- JJG 960-2001
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement performance requirements (1)
- 3.1 I angle micrometer indication error (1)
- 3.2 Flat panel microcomputer indication error (1)
- 3.3 Micro tilting table indication error (1)
- 3.4 Horizontal line compensator compensation error (1)
- 3.5 Horizontal Alignment Deviation (2)
- 3.6 Multi-target deviation from the line error (2)
- 4 General technical requirements (2)
- 4.1 Appearance (2)
- 4.2 Interaction of components (2)
- 5 Measuring instruments (2)
- 5.1 Test conditions (2)
- 5.2 Verification Project (3)
- 5.3 Verification method (3)
- 5.4 Processing of test results (8)
- 5.5 Test cycle (8)
- Appendix A Calculation Form (9)
- Appendix B Automatic Anping Level Verification Device Horizontal Alignment Deviation Method
- APPENDIX C INSPECTION CERTIFICATE AND QUALIFICATION RESULTS Notice Page Format (12)
- Appendix D Level Level Verification Device Horizontal Alignment Deviation Measurement Results Uncertainty Evaluation Report Example (13)
1 Scope (1)
2 Overview (1)
3 Measurement performance requirements (1)
3.1 I angle micrometer indication error (1)
3.2 Flat panel microcomputer indication error (1)
3.3 Micro tilting table indication error (1)
3.4 Horizontal line compensator compensation error (1)
3.5 Horizontal Alignment Deviation (2)
3.6 Multi-target deviation from the line error (2)
4 General technical requirements (2)
4.1 Appearance (2)
4.2 Interaction of components (2)
5 Measuring instruments (2)
5.1 Test conditions (2)
5.2 Verification Project (3)
5.3 Verification method (3)
5.4 Processing of test results (8)
5.5 Test cycle (8)
Appendix A Calculation Form (9)
Appendix B Automatic Anping Level Verification Device Horizontal Alignment Deviation Method
APPENDIX C INSPECTION CERTIFICATE AND QUALIFICATION RESULTS Notice Page Format (12)
Appendix D Level Level Verification Device Horizontal Alignment Deviation Measurement Results Uncertainty Evaluation Report Example (13)
Introduction
JJG 425 "level", JJG 8 "level scale" and JJG 960 "level test device" together constitute a large Measures for the measurement of the leveling of instruments.
JJG 960-2012 "Level Verification Device" is written in JJF1002-2010 "National Metrological Verification Regulation the JJG 960-2001 "Level Verification Device" is revised on the basis of the rules and basis. versus JJG 960-2001 "level test device" compared to the editorial changes in the main technical changes are as follows.
--- JJG 425-1994 "Level" and JB/T 7399-1994 "Parallel light pipe" are cited in the literature.
Metrological performance requirements increase the i-angle micrometer indication error requirements, easy to improve the accuracy of the test;
Cancel the parallel light pipe focal length and scale instructions error requirements.
- The range of measurement of the level calibrator has been modified in the procedure.
- the calibration method, the level of deviation for the automatic Anping and self-collimation of these two devices were done Introduction.
- In Appendix B, an automatic ampere-type verification device is introduced for the use of the device itself.
Number, only the level of the pedal to complete the test method.
Level Verification Device
1 Scope
This procedure applies to all types of level test device of the first test, follow-up inspection and use of inspection.
2 Overview
Level measuring device is a kind of measuring device which can produce a horizontal line and can realize multi-target Mainly used for level calibration or calibration. According to the structure it can be divided into automatic Anping (see Figure 1) and self-collimation (see Figure
2), according to the level of deviation of its accuracy can be divided into 1, 2 and 3.
Figure 1 Schematic diagram of automatic Anping level tester
1 - automatic Anping parallel light tube; 2 - was seized level
Figure 2 from the collimation level level test device diagram
1 - parallel light tube; 2 - seized level
3 Measurement performance requirements 3.1 i angle micrometer indication error i angle micrometer indication error requirements in Table 1.
3.2 flat panel microcomputer indication error Flat plate microcomputer indication error requirements in Table 1.
3.3 micro tilting table indication error Micro tilting table indication error requirements see Table 1.
3.4 Horizontal alignment compensator compensation error Horizontal line compensator compensation error requirements in Table 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
How to Download JJG 960-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1201-2024 — Digital Tyre Pressure Gauges
JJG 1202-2024 — Long Distance Transmissible Pressure Gauges
JJG 746-2024 — Ultrasonic Flaw Detectors
Secure payment via Stripe
Payments accepted
JJG 960-2012