Valid

JJG 938-2012Verification Regulation of Tool Presetling and Measuring Instrument (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JJG 938-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

JJG 938-2012 (Verification Regulation of Tool Presetling and Measuring Instrument) is available as an English-translated PDF.

JJG 938-2012 — This standard applies to measuring range (0 ~ 1000) mm for tool presetting meter initial verification, testing and use of follow-up checks.

Found what you need?

Document preview — JJG 938-2012

National Standard of the People's Republic of China

ICS
17.040
Classification
A 52
Replacing
JJG 938-1998

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Overview (1)
  • 4 Metering performance requirements (1)

1 Scope (1)

2 References (1)

3 Overview (1)

4 Metering performance requirements (1)

Projection magnification 4.1 (1)

4.2 Test rods and spindle taper taper shape error and error (2)

4.3 Axial movement of the spindle (2)

4.4 Spindle radial runout (2)

4.5 Sighting device parallel with the axial movement of the spindle (2)

4.6 Degree vertical aiming device along the radial motion of the spindle (2)

4.7 Measurement repeatability (2)

4.8 Indication error (2)

5 General technical requirements (3)

5.1 Appearance (3)

5.2 Interaction of each part (3)

5.3 Mass imaging optical system (3)

5.4 Two reticle superposition (3)

The relative position of the spindle and the object plane of the projection system 5.5 (3)

6 Control of measuring instruments (3)

6.1 Verification condition (3)

6.2 Verification Project (4)

6.3 Verification Methods (4)

Processing 6.4 Verification Results (7)

6.5 Test cycle (7)

Appendix A tool presetting measurement uncertainty of measurement instrument indication error of assessment (8)

Appendix B test mandrel and the test disc (10)

Appendix C calibration certificate/test results in the notice page and format (12)

Introduction

JJF1002-2010 "national verification procedures write rules", JJF1001-2011 "common terminology and measurement Definitions ", JJF1059-1999" Evaluation and Expression of Uncertainty in Measurement ", JJG 938-1998" measuring tool presetting Instrument "(hereinafter referred to as" the original Regulations ") together constitute the basic norms of the present series of regulations revision.

This regulation, the term modified according to GB/T 22096-2008 "tool presetting measuring instrument" Terminology and unity.

This procedure is revised on the basis of the original procedure. Compared with the original regulations, in addition to editorial changes, the main technical change of the following.

--- According to GB/T 22096-2008 "tool presetting measuring instrument", the new increase precision, ordinary type and Jane Yi-based technical requirements.

--- Remove the spindle taper and test rods taper shape error and error in the technical parameters and form.

--- According to GB/T 22096-2008 "tool presetting measuring instrument" on the sighting device along the radial motion of the spindle Squareness measurement repeatability and other technical requirements adopted tabular representation.

--- According to GB/T 22096-2008 "tool presetting measuring instrument", the spindle radial runout, aiming device Parallel to the direction of axial movement of the spindle, showing error such as the use of the formula.

--- Amendments to the original protocol section of the metering apparatus name, "the relative position of the object plane of the projection system and the spindle," "Lord Shaft axial movement, "" radial shaft runout "project" Calibration stick "to" mandrel test "," aiming device axis in the direction of movement of the spindle parallelism "project" test stick "to" mandrel test "," aiming device radially Vertical movement of the spindle of the "project" dedicated gage "to" test disc, "" measurement repeatability "project the "Calibration stick" to "test rods."

--- According to GB/T 22096-2008 "tool presetting measuring instrument" to delete the original statutes "slide axially transport Moving pendulum angle "and" radial angle skateboarding pendulum, "the two test projects.

Tool presetting measuring instrument verification regulation

1 Scope

The order applies to the measurement range (0 ~ 1000) mm tool presetting measuring instrument (hereinafter referred to as "knife adjustment Instrument ") of the initial verification, use and subsequent verification check.

2. References

This procedure references the following documents.

GB/T 22096-2008 tool presetting measuring instrument for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.

3 Overview

Presetter mainly used in CNC machine tools, machining centers and flexible manufacturing cell used in the cutting edge of the radial and axial Size measurement. Presetter into precision type, ordinary type and Simple. Presetter is shown in Figure 1.

Figure 1 schematic presetter

1- base; 2- radial slide; 3- column; 4- slide axially;

5- display device; 6- sighting device; 7- test mandrel; 8- spindle 4 metering performance requirements 4.1 projection magnification

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

How to Download JJG 938-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included