JJG 863-2005Verification Regulation of V-prism Refractometer (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for JJG 863-2005 in 30 minutes.

Issued by

The General Administration of Quality Supervision, Inspection and Quarantine issued, This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 3,.2005, and

Level / Type

National · Mandatory

Issue date

March 3, 2005

Implementation date

September 3, 2005

Scope

JJG 863-2005 (Verification Regulation of V-prism Refractometer) is available as an English-translated PDF.

JJG 863-2005 — This standard applies to V-prism refractometer initial verification, testing and use of follow-up inspection.

Found what you need?

Document preview — JJG 863-2005

National Standard of the People's Republic of China

ICS
17.180
Classification
A 60
Replacing
JJG 863-1994

Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 3,.2005, and

Contents

  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metrological performance requirements (3)
  • 3.1 Differential measurement system line difference (3)
  • 3.2 The micro-measurement of the micro-reading system (3)
  • 3.3 Correction block 90° angular error (3)
  • 3.4 V prism two-pass light end face parallel difference and V-shaped groove 90 ° angle error (3)
  • 3.5 Refractive index measurement error (3)
  • 3.6 Refractive index measurement repeatability (3)
  • 4 General technical requirements (3)
  • 4.1 Appearance (3)
  • 4.2 Instrument Accessories (3)
  • 4.3 Optical System Imaging Quality (3)
  • 4.4 Parallax (4)
  • 4.5 Parallel difference (4)
  • 5 Measuring instrument control (4)
  • 5.1 Verification conditions (4)
  • 5.2 Verification project (4)
  • 5.3 Verification method (4)
  • 5.4 Processing of verification results (8)
  • 5.5 Verification cycle (8)
  • Appendix A Refractive Index and Preparation Method of Common Refraction Fluid (9)
  • Appendix B Micrometer reading system line difference verification record and calculation example (10)
  • Appendix C Example of the idle test record and calculation of the micrometric reading system (11)
  • Appendix DV Prism Refractometer Calibration Record Format (12)
  • Appendix EV Prism refractometer verification certificate, verification result notice page format (17)
  • Appendix F Example of Measurement Uncertainty Evaluation of Verification Results (18)

1 Scope (1)

2 Overview (1)

3 Metrological performance requirements (3)

3.1 Differential measurement system line difference (3)

3.2 The micro-measurement of the micro-reading system (3)

3.3 Correction block 90° angular error (3)

3.4 V prism two-pass light end face parallel difference and V-shaped groove 90 ° angle error (3)

3.5 Refractive index measurement error (3)

3.6 Refractive index measurement repeatability (3)

4 General technical requirements (3)

4.1 Appearance (3)

4.2 Instrument Accessories (3)

4.3 Optical System Imaging Quality (3)

4.4 Parallax (4)

4.5 Parallel difference (4)

5 Measuring instrument control (4)

5.1 Verification conditions (4)

5.2 Verification project (4)

5.3 Verification method (4)

5.4 Processing of verification results (8)

5.5 Verification cycle (8)

Appendix A Refractive Index and Preparation Method of Common Refraction Fluid (9)

Appendix B Micrometer reading system line difference verification record and calculation example (10)

Appendix C Example of the idle test record and calculation of the micrometric reading system (11)

Appendix DV Prism Refractometer Calibration Record Format (12)

Appendix EV prism refractometer verification certificate, verification result notice page format (17)

Appendix F Example of Measurement Uncertainty Evaluation of Verification Results (18)

V prism refractometer verification procedure

1 Scope

This procedure applies to the first verification, subsequent verification and in-use inspection of the V-prism refractometer. V prism refractometer the requirements for the relevant metrological performance in the type identification and prototype test can be carried out with reference to this regulation.

2 Overview

The V prism refractometer (hereinafter referred to as the refractometer) uses a vertical precision goniometer to measure the refractive index by the V prism method.

An instrument.

The measurement principle of the refractive index measured by the V prism method is shown in Fig. 1.

Figure 1 V prism method to measure the refractive index

1-V prism; 2-sample to be tested the V prism is a rectangular prism with a "V" shaped notch. The two materials are identical and have a refractive index.

The right angle prism of n0 is glued together, the opening angle of the V-shaped notch is angleAED=90°, and the angle of the two sharp edges is angleBAE= angleCDE=45°. The measured sample is ground out to form two planes of 90° in the V-shaped notch, due to sample angle processing the error, there will be a gap between the two faces of the sample to be tested and the two faces of the V-shaped notch, and some need to be filled in the middle A liquid having a refractive index close to that of the sample to be measured becomes a refractive liquid. The effect of the refraction fluid is even if the sample is processed at a 90° angle Inaccurate, plus the refractive fluid, approximates an accurate 90° angle, and prevents the light from being completely reversed at the interface.

Shoot.

Vertically entering the AB plane of the V prism with a monochromatic parallel light, if the refractive index n of the sample to be measured and the known V prism the refractive index n0 is the same, then the entire V prism plus the sample to be tested is like a parallel flat glass, the light is in two There is no deflection on the contact surface, and the final outgoing light will not be deflected. If the refractive indices of the two are not equal, then the light is deflected on the contact surface, and the final outgoing light has a deflection angle theta with respect to the incident light.

The magnitude of the angle theta is related to the refractive index n of the sample to be tested. The V prism method is to accurately measure the value of the deflection angle theta,

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

How to Download JJG 863-2005

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 863-2005

$345.00