JJG 860-2015Verification Regulation of Pressure Transducer (Static) (English PDF)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JJG 860-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 30, 2015
Implementation date
July 30, 2015
Scope
JJG 860-2015 (Verification Regulation of Pressure Transducer (Static)) is available as an English-translated PDF.
JJG 860-2015 — This Standard specifies the measuring the range of (-0.1 ~ 500) MPa (gauge pressure, differential or absolute pressure) sensor (static) initial verification, subsequent verification and the use of checks.
Found what you need?
Document preview — JJG 860-2015
National Standard of the People's Republic of China
- ICS
- 17.100
- Classification
- A 53
- Replacing
- JJG 860-1994
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 The term (1)
- 3.2 Units of measurement (1)
- 4 Overview (2)
- 5 Metering performance requirements (2)
- 5.1 Level of accuracy and basic error limit (2)
- 5.2 Repeatability (2)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 The term (1)
3.2 Units of measurement (1)
4 Overview (2)
5 Metering performance requirements (2)
5.1 Level of accuracy and basic error limit (2)
5.2 Repeatability (2)
Hysteresis 5.3 (2)
Linear 5.4 (2)
5.5 Zero drift (2)
5.6 Cycle stability (3)
5.7 Static pressure effects (3)
5.8 Compliance curve (3)
6 General Requirements (3)
6.1 Appearance (3)
Tightness 6.2 (3)
6.3 Insulation resistance (3)
7 Control of measuring instruments (3)
7.1 Test conditions (3)
7.2 Verification Project (5)
7.3 Verification Methods (5)
7.4 Test results processing (12)
7.5 Test cycle (12)
Appendix A height difference correction method (13)
Appendix B Pressure sensor (static) test recording format (14)
Appendix C Pressure Sensor (static) calibration certificate/test results in the notice page format (15)
Introduction
JJF1002 "national verification procedures write rules", JJF1001 "common measurement terms and definitions" JJF1008 "Pressure measurement terminology and definitions" series together constitute the basic norms of the regulations revision.
This procedure combined with China's national conditions, the basis of "pressure sensor (static)" verification procedures in JJG 860-1994 on the use of GB/T 15478-1995 "pressure sensor performance test method", GB/T 18459-2001 "Biography Sensor main static performance index calculation method ", GB/T 18806-2002" total resistance strain gauge pressure sensor Fan ", GB/T 20522-2006" Semiconductor devices Part 14-3. Semiconductor sensors - Pressure sensor " Part of the contents in the reserve JJG 860-1994 effective content premise of the amendment.
The procedures and JJG 860-1994 "pressure sensor (static)" compared to, in addition to editorial changes, the major change of the following.
--- Redefined the pressure sensor accuracy class division;
--- Refine the test conditions and test methods;
--- Expands the measurement performance pressure sensors and general technical requirements;
--- Increasing the test project content;
--- Straighten out the order of test items and test methods;
--- Increasing the height difference correction calculation in the appendix.
A pressure sensor (static) test procedures
1 Scope
The test procedures for measuring the range (-0.1 ~ 500) MPa (gauge pressure, differential or absolute pressure) Biography Sensors (static) initial verification, use and subsequent verification check.
2. References
This procedure references the following documents.
JJF1008-2008 pressure measurement terminology and definitions GB/T 15478-1995 pressure sensor performance test method GB/T 18459-2001 sensor is mainly static performance index calculation method GB/T 18806-2002 total resistance strain pressure sensor specification GB/T 20522-2006 Semiconductor devices Part 14-3. Semiconductor sensors - Pressure Sensor for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.
3 terminology and units of measurement
3.1 Terms
3.1.1 Static pressure in the field of research, does not change with time or change over time and slowly varying pressure. [JJF1008-2008 definitions 1.8]
3.1.2 Pressure Sensor pressuretransducer You can feel the pressure signal, and in accordance with certain rules the pressure signal is converted into usable electrical signal output device or device. [JJF1008-2008 Definition 5.1]
3.1.3 Zero drift and a time interval, the output value of zero amount of change under specified conditions.
3.1.4 Sensitivity the amount of change of the sensor output corresponding to the amount of change in the input ratio. [GB/T 18459-2001 defined 2.3.2] 3.1.5 conformity the percentage positive, the actual average anti-stroke characteristic curve with respect to the maximum deviation of the reference curve, with the full-scale output to represent. [GB/T 18459-2001 defined 2.3.6] 3.2 units of measurement Legal units of measurement used for the pressure sensor Pa (Pascal), or its decimal multiples units. kPa, MPa and the like. The main pressure sensor output voltage (V, mV), current (mA) or frequency (Hz) and the like.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download JJG 860-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 860-2015