Valid

JJG 841-2012Verification Regulation of Microwave Frequency Counters (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for JJG 841-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

JJG 841-2012 (Verification Regulation of Microwave Frequency Counters) is available as an English-translated PDF.

JJG 841-2012 — This standard applies to the frequency range of 100kHz ~ 40GHz microwave frequency counters and other instruments in the microwave frequency counter function module initial verification, testing and use of follow-up checks.

Found what you need?

Document preview — JJG 841-2012

National Standard of the People's Republic of China

ICS
17.080
Classification
A 57
Replacing
JJG 841-1993

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terms (1)
  • 3.1 Input sensitivity (1)
  • 3.2 Maximum Input Level (1)
  • 4 Overview (1)
  • 5 Metering performance requirements (1)
  • 5.1 Input characteristics (1)
  • 5.2 Frequency measurement error (2)
  • 5.3 Built-in quartz crystal oscillator (2)
  • 6 General Requirements (2)
  • 6.1 Appearance (2)
  • 6.2 Of the work (2)
  • 7 Control of measuring instruments (2)
  • 7.1 Verification Conditions (2)
  • 7.2 Test items and test methods (3)
  • 7.3 Verification Results Processing (6)
  • 7.4 Test cycle (6)
  • Appendix A Test page original record data format (7)

1 Scope (1)

2 References (1)

3 Terms (1)

3.1 Input sensitivity (1)

3.2 Maximum Input Level (1)

4 Overview (1)

5 Metering performance requirements (1)

5.1 Input characteristics (1)

5.2 Frequency measurement error (2)

5.3 Built-in quartz crystal oscillator (2)

6 General Requirements (2)

6.1 Appearance (2)

6.2 of the work (2)

7 Control of measuring instruments (2)

7.1 Verification Conditions (2)

7.2 Test items and test methods (3)

7.3 Verification Results Processing (6)

7.4 Test cycle (6)

Appendix A test page original record data format (7)

B test certificates/test results in the notice page format Shape Appendix (9)

Introduction

JJG 841 "microwave frequency counter" is the revised version of JJG 841-1993 conducted. And JJG 841-1993 Compared to, in addition to editorial changes outside the main technical changes are as follows.

--- Increase the frequency measurement limit (see Chapter 1);

--- New introduction, the term content (see Introduction and Chapter 3);

--- Complement the performance requirements for content measurement (see Chapter 5);

--- Refine and clarify the test conditions (see 7.1);

--- Provisions of the applicable conditions of different test methods, eliminating synthetic, frequency converters, modular signal attenuator Generating method and splitters method (see 7.2.2.3);

--- New frequency measurement error test items and test methods (see 5.2 and 7.2.2.4);

--- Test new original record data page format (see Appendix A), calibration certificate/test results within the page frame notice Type style (see Appendix B).

JJG 841-1993 for the first release.

Microwave frequency counter test procedures

1 Scope

The order applies to the measurement frequency range of 100kHz ~ 40GHz microwave frequency counter and other instruments the microwave frequency counting function module initial verification, use and subsequent verification check.

2. References

JJG 180-2002 "electronic measuring instruments within the quartz oscillator" for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.

3 Terms

3.1 Input sensitivity Microwave frequency counter works fine and the reading is stable, the measured signal is accurate minimum required level value.

3.2 Maximum input level Microwave frequency counter works fine and the reading is stable, the measured signal is accurate can withstand the maximum level value.

4 Overview

Microwave frequency counter frequency measurement refers to the upper reaches of the microwave frequency counter, also known as the microwave frequency counter. it Usually down-conversion technology, microprocessor controlled by the frequency of the measured microwave signals can be converted into a counter Direct measurement of the frequency, widely used in national defense, scientific research, universities and military departments measuring microwave, millimeter wave band power Signal frequency.

5 metering performance requirements

5.1 Input characteristics Input characteristics are shown in Table 1.

Table 1 Input characteristics

Technical Specifications Bands Frequency range 100kHz ~ 1GHz (1 ~ 18) GHz (18 ~ 26.5) GHz (26.5 ~ 40) GHz Input sensitivity (20 ~ 300) mV (-33 ~ -20) dBm (-29 ~ -17) dBm (-23 ~ -15) dBm the maximum input level (2 ~ 7) V (5 ~ 13) dBm (7 ~ 13) dBm (7 ~ 13) dBm BNC input connector type N-type socket/SMA and other 3.5mm/K type, etc. 2.4mm/K type, etc.

Note. The band division and technical specifications to the product specification shall prevail.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download JJG 841-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 841-2012

$394.00