Valid

JJG 814-2015Verification Regulation of Automatic Potentiometric Titrators (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (14 pages)

Need quotation for your management?

Get a formal quotation for JJG 814-2015 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 30, 2015

Implementation date

July 30, 2015

Scope

JJG 814-2015 (Verification Regulation of Automatic Potentiometric Titrators) is available as an English-translated PDF.

JJG 814-2015 — This Standard applies to automatic potentiometric titrator initial verification, subsequent verification and the use of checks.

Found what you need?

Document preview — JJG 814-2015

National Standard of the People's Republic of China

ICS
17.020
Classification
A 55
Replacing
JJG 814-1993

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metering performance requirements (1)
  • 4 General Requirements (2)
  • 4.1 Appearance and routine examination (2)
  • 4.2 Energizing check (2)
  • 5 Control of measuring instruments (2)
  • 5.1 Verification Conditions (2)
  • 5.2 Test items and test methods (3)
  • 5.3 Verification Results Processing (6)
  • 5.4 Test cycle (6)
  • Appendix A Test segment burette (7)
  • Appendix B Common Glass Container Measurement Approach K (t) value table (8)
  • Appendix C Test original record format (10)
  • Appendix D Calibration certificate/test results in the notice page format pattern (13)

1 Scope (1)

2 Overview (1)

3 Metering performance requirements (1)

4 General Requirements (2)

4.1 Appearance and routine examination (2)

4.2 Energizing check (2)

5 Control of measuring instruments (2)

5.1 Verification Conditions (2)

5.2 Test items and test methods (3)

5.3 Verification Results Processing (6)

5.4 Test cycle (6)

Appendix A test segment burette (7)

Appendix B Common Glass Container Measurement Approach K (t) value table (8)

Appendix C test original record format (10)

Appendix D calibration certificate/test results in the notice page format pattern (13)

Introduction

The procedure according to JJF1002-2010 "national verification procedures to write the rules," to write, and JJG 814-1993 compared to, in addition to editorial changes, the major technical changes are as follows.

--- Increased contents Introduction;

--- Original statutes "electricity meter reference repeatability errors, potential electricity meter, Burette capacity Tolerance, titration analysis Repeatability "project name was changed to" electricity meter indication error, electricity meter Repeatability, Buret capacity error, equipment Repeatability ";

--- Modify the calculation method of "electric meter Repeatability" (see 5.2.2.4);

--- Modify the content verification of environmental conditions (see 5.1.1);

--- Cancel the test standard is the "high impedance DC potentiometer, standard battery and a galvanometer and other components of the standard Verification device "will" or with the same accuracy DC potential Calibrator "was changed to" pH Calibrator. accuracy class 0.0006; "(see 5.1.3);

--- Added "certified reference material" requirements (see 5.1.4);

--- Increased the list of test items (see Table 3);

--- Cancel the original statutes "instrument control titration sensitivity" of technical indicators;

--- Modified "Buret capacity error," the test methods (see 5.2.2.7);

--- Added "instrument indication error" technical indicators and test methods (see 5.2.2.8);

--- Original statutes "potentiometric titration instrument repeatability test" and "instrument and titration repeatability test" Merge, modify the "Instrument Repeatability" and modified its test method (see 5.2.2.8);

--- Added "common method to measure Glass Container K (t) value table" (see Appendix B);

--- Modify the "verification original record format" appendix (Appendix C);

--- Cancel the original statutes "verification certificate" appendix, from "test certificate/test results in the notice page format Shape "Appendix D instead.

The regulations previously issued as follows.

--- JJG 814-1993.

Automatic potentiometric titrator verification procedures

1 Scope

The order applies to automatic potentiometric titrator initial verification, use and subsequent verification check.

2 Overview

Automatic potentiometric titrator (hereinafter referred to as equipment) is based on the principle of potentiometric titration designed for a capacity analysis Kinds of analytical instruments.

Potentiometric titration principle is. the choice of appropriate indicator electrode and a reference electrode and the measured ratio of the solution to form a working electrode Pool, with the addition of titrant, as a result of a chemical reaction, the concentration of the measured ion is changing, thus indicating the electrode potential changes. Near the end of the titration, ion concentration measured mutation causing sudden electrode potential jump. Thus, according to the projection electrode potential jump can determine the endpoint. It is the potentiometric titration curve, A point shown in Figure 1 the endpoint of the titration.

1 a schematic diagram of potentiometric titration curve Instruments distributor gauge system titration system and electrode system consists of three parts. Electricity meter system consists of potential amplification, control lines Composition, by measuring the indicator electrode and the reference electrode between the ratio of signal processing, the automatic control system of the droplet titration Fluid velocity, is determined after the end of the titration, the instrument automatically stops the titration. Titration system is divided into digital and scale burette two Categories. Electrode system by the indicator electrode and the reference electrode.

3 metering performance requirements Automatic titrator performance measurement requirements in Table 1, Table 2.

Table 1 List of instrument performance measurement

Instrument Level

Measurement of performance Electricity meter shows the maximum value Allowable error % FS Electricity meter indication Repeatability Enter the electricity meter Electric current Electricity meter input impedance Instrument shows maximum value Allowable error Instrument indication Repeatability 0.05 ± 0.05 <=0.025 <=1 × 10-12 >=3 × 1012 ± 1.5 <=0.2

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download JJG 814-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 814-2015

$295.00