JJG 776-2014Verification Regulation for Microwave Radiation and Leakage Energy Measuring Instruments (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (10 pages)

Need quotation for your management?

Get a formal quotation for JJG 776-2014 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 23, 2014

Implementation date

July 23, 2014

Scope

JJG 776-2014 (Verification Regulation for Microwave Radiation and Leakage Energy Measuring Instruments) is available as an English-translated PDF.

JJG 776-2014 — This Standard applies to the operating frequency range of 915MHz-18GHz microwave radiation measuring instrument for the first time with the leak test, follow-up testing and use of checks.

Found what you need?

Document preview — JJG 776-2014

National Standard of the People's Republic of China

ICS
17.240
Classification
A 58
Replacing
JJG 776-1992

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metering performance requirements (1)
  • 4 General Requirements (1)
  • 5 Control of measuring instruments (1)
  • 5.1 Test conditions (1)
  • 5.2 Test items and test methods (3)
  • 5.3 Test results processing (4)
  • 5.4 Test cycle (4)
  • Appendix A Test recording format (5)
  • Appendix B Test certificates/test results in the notice page and format (6)

1 Scope (1)

2 Overview (1)

3 Metering performance requirements (1)

4 General Requirements (1)

5 Control of measuring instruments (1)

5.1 Test conditions (1)

5.2 Test items and test methods (3)

5.3 Test results processing (4)

5.4 Test cycle (4)

Appendix A test recording format (5)

Appendix B test certificates/test results in the notice page and format (6)

Introduction

The regulations refer to international standards IEEEStd1309-2005, IEEEStandardforCalibrationofElec-tromagneticFieldSensorsandProbes, ExcludingAntennas, from9kHzto40GHz be prepared by. The standard is based on the current major international calibration laboratories electromagnetic field probe and sensor calibration.

The procedures in place JJG 776-92 "Microwave radiation and leakage measurement instrument." The version with procedures and JJG 776-92 Than the power density of the device used in the device varies. In addition, the test frequency limit extended to 18GHz, for Verification also in the basic range of minor changes to the (0 ~ 1) mW/cm2 as the basic range of the test, if the subject Instrument range than 1mW/cm2, the increase (1 ~ 3) mW/cm2 power density of the measurement values.

The previous versions of the release JJG 776 case.

--- JJG 776-1992.

Microwave radiation and leakage meter

1 Scope

This procedure is applied for the first time in the operating frequency range of 915MHz ~ 18GHz microwave radiation leakage and measuring instrument Test, test and subsequent use of checks.

2 Overview

Microwave radiation and leakage meter is used to measure radiation and microwave equipment microwave energy leaking to the space instruments.

Microwave probe of the electromagnetic field sensitive element, can be directly converted microwave signal into a DC signal, the indicator value.

3 metering performance requirements Frequency range. 915MHz ~ 18GHz;

Power density measurement range. (0 ~ 3) mW/cm2;

Power density measurement maximum permissible error. ± 2.75dB.

4 General technical requirements it should be the subject instrument manufacturer, instrument name, instrument model, serial number and power requirements information. Microwave radiation and leakage measurement instrument control buttons, key switch, input and output ports should be clearly marked, and having a metering device A manufacturing license logo.

There should be no prejudice to the subject instrument readings and affect the normal mechanical damage, control knobs and buttons should be able to work properly for the display to show, all kinds of signs should be clear and complete; pointer instrument gauge needles should bend, mechanical meter Zero can be adjusted freely.

5 control of measuring instruments Controls include initial verification of measuring instruments, verification and subsequent use of checks.

5.1 Verification Conditions

5.1.1 Environmental conditions

1) Ambient temperature. (23 ± 5) °C.

2) Relative Humidity. 20% to 80%.

3) Power supply voltage and frequency. (220 ± 11) V, (50 ± 1) Hz.

4) The laboratory shall be no severe impact and vibration measurements of electromagnetic interference.

5.1.2 The test equipment

5.1.2.1 Power density means the overall requirements of the standard

Frequency range. 915MHz ~ 18GHz;

The maximum power density value. >=3mW/cm2;

Standard power density Uncertainty. <=1dB.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

How to Download JJG 776-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 776-2014

$225.00