JJG 773-2013Verification Regulation of Medical Radiation Source for γ-ray Afterloading Brachytherapy (English PDF)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JJG 773-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJG 773-2013 (Verification Regulation of Medical Radiation Source for γ-ray Afterloading Brachytherapy) is available as an English-translated PDF.
JJG 773-2013 — This standard applies to medical γ-ray after-loading brachytherapy radiation (dose rate range of about 0. 01 Gy/min ~ 5 Gy/min) the initial verification, follow-up test and use checks.
Found what you need?
Document preview — JJG 773-2013
National Standard of the People's Republic of China
- ICS
- 17.240
- Classification
- A 58
- Replacing
- JJG 773-1992
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 The term (1)
- 3.2 Units of measurement (2)
- 4 Overview (2)
- 5 Metering performance requirements (2)
- 5.1 Dose repeatability (2)
- 5.2 Dose error (2)
- 5.3 Source equivalent activity (2)
- 5.4 Radiation directivity (2)
- 5.5 Transfer position deviation source (2)
- 6 General technical conditions (3)
- 6.1 Equipment Signs (3)
- 6.2 Display (3)
- 7 Control of measuring instruments (3)
- 7.1 Test conditions (3)
- 7.2 Verification Project (4)
- 7.3 Verification Methods (4)
- 7.4 Verification Results Processing (7)
- 7.5 Test cycle (7)
- Appendix A Of the ionization chamber line correction factor (8)
- Appendix B And the water absorbed dose conversion factor Clambdax and exposure to air kerma conversion factor Clambdak (9)
- Appendix C After brachytherapy commonly used radionuclides exposure rate constant taux and air kerma rate constant tauk (10)
- Appendix D Aqueous medium attenuation and scatter correction factor S (r) (11)
- Appendix E Water phantom measuring bracket (12)
- Appendix F Medical gamma rays after loading brachytherapy radiation test recording format pattern (13)
- Appendix G Calibration certificate/test results in the notice page format pattern (15)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 The term (1)
3.2 Units of measurement (2)
4 Overview (2)
5 Metering performance requirements (2)
5.1 Dose repeatability (2)
5.2 Dose error (2)
5.3 Source equivalent activity (2)
5.4 Radiation directivity (2)
5.5 Transfer position deviation source (2)
6 General technical conditions (3)
6.1 Equipment Signs (3)
6.2 Display (3)
7 Control of measuring instruments (3)
7.1 Test conditions (3)
7.2 Verification Project (4)
7.3 Verification Methods (4)
7.4 Verification Results Processing (7)
7.5 Test cycle (7)
Appendix A of the ionization chamber line correction factor (8)
Appendix B and the water absorbed dose conversion factor Clambdax and exposure to air kerma conversion factor Clambdak (9)
Appendix C after brachytherapy commonly used radionuclides exposure rate constant taux and air kerma rate constant tauk (10)
Appendix D aqueous medium attenuation and scatter correction factor S (r) (11)
Appendix E water phantom measuring bracket (12)
Appendix F Medical gamma rays after loading brachytherapy radiation test recording format pattern (13)
Appendix G calibration certificate/test results in the notice page format pattern (15)
Introduction
This procedure based on JJF1002-2010 "national verification procedures to write the rules" to prepare.
The regulations replace JJG 773-1992 "close after gamma-ray radiation brachytherapy." this procedure compared with JJG 773-1992, in addition to editorial changes, the main technical differences are as follows.
--- According to the requirements JJF1002-2010, an increase of introduction;
--- Increasing the ionization chamber line of the amended definition (see 3.1.5); and in absorbed dose calculation formula, modify agent the amount of the gradient correction factor for the ionization chamber line of the correction factor (see 7.3.2.1 and Appendix A);
After loading dose radiation output --- modified randomly selected multiple sources (radiation) source system repeatability to Seek, from 5% modified to not more than 3.0% (see 5.1.2);
--- Increase the radiation directivity requirements and test methods (see 5.4 and 7.3.4);
--- Modify the phantom and measurement bracket requirements (see 7.1.2.2);
--- Increasing the absorbed dose to the applicator error assays and kinds of provisions "when the test is administered must Comprising at least one metal hose applicator and applicator "(see 7.3.2.5);
Test methods --- transmission source of bias in place, for photographic film with a slow method of modifying the original procedures described Said that verification operational, while the image size by specifying sources formed to standardize imaging quality Volume, thereby improving the accuracy of measurement (see 7.3.5.1);
--- Increasing the typical radionuclide air kerma conversion factor Clambdak value queries (see Appendix B).
The previous versions of the release JJG 773 case.
--- JJG 773-1992.
After the medical device gamma-ray brachytherapy Radiation test procedures
1 Scope
The order applies to medical gamma-ray after-loading brachytherapy radiation (dose rate range of about 0.01Gy/min ~ 5Gy/min) the initial verification, use and subsequent verification check.
This procedure does not apply to medical neutron radiation sources close brachytherapy, radiation therapy and medical Sticking seed implantation Radiation therapy and other verification.
2. References
This procedure references the following documents.
JJF1035 ionizing radiation measurement terms and definitions GB 4075 Sealed radioactive sources - General requirements and classification GB 9706.13-2008 Medical electrical equipment - Part 2. automatic control of brachytherapy equipment installed Requirements for safety (IEC 60601-2-17:2004, IDT) GB Z121-2002 after loading brachytherapy source gamma health protection standard for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.
3 terminology and units of measurement JJF1035 "ionizing radiation measurement terminology and definitions" and defined the following terms and definitions apply to this procedure.
3.1 Terms
3.1.1 After installation technology afterloadingtechniques Pre-positioned in a patient in need of treatment administered the site correctly, then the inner receptacle radioactive source is input applicator in the implementation of treatment technologies.
3.1.2 gamma-rays after loading brachytherapy gamma-rayafterloadingbrachytherapy with mounting technology, in accordance with the clinical requirements, so that gamma radioactive source resides or shipped between the body's natural cavity, duct or tissue Moving, but to achieve a predetermined dose of radiation treatment and distribution.
3.1.3 applicator radiationsourcesapplicator Previously placed between the body cavity, duct or tissue, for presence or movement of radioactive sources, and the implementation of a special container treatment Treatment is also known. Such as a needle, tube, or have other special shape of the applicator.
3.1.4 source storage device storecontainerofradiationsources After the storage container brachytherapy radioactive sources.
3.1.5 ionization chamber line corrections correctionofionizationchamberdimension in the dose distribution, since the distance between the point source is too close, the ionization chamber can not be seen as a correction point detectors carried out, such a Fixed distance main ionization chamber cavity with maximum size and point source related to the ionization chamber.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download JJG 773-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 773-2013
$315.00