JJG 755-2015Ultraviolet Irradiance Working Standard Apparatus (English PDF)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JJG 755-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
December 7, 2015
Implementation date
June 7, 2016
Scope
JJG 755-2015 (Ultraviolet Irradiance Working Standard Apparatus) is available as an English-translated PDF.
JJG 755-2015 — This standard is applicable to the first verification, follow-up verification and inspection during operation of the UV-irradiance reference device.
Found what you need?
Document preview — JJG 755-2015
National Standard of the People's Republic of China
- ICS
- 17.180
- Classification
- A 60
- Replacing
- JJG 755-1991
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Overview (1)
- 4 Measurement performance requirements (1)
- 4.1 Spectral response and band division of the device (1)
- 4.2 Annual change rate of the device (2)
- 4.3 Operating Baseline Ultraviolet Radiation Illuminance Zero Error (Full Scale FS) (2)
- 4.4 Working reference UV radiation illuminator long wave response error (2)
- 4.5 Working Baseline Ultraviolet radiation Illuminance meter cosine characteristics (directional response) (2)
- 4.6 Working standard Non-linearity error of ultraviolet radiation illuminometer (2)
- 4.7 Work reference UV radiation illuminometer shift error (2)
- 4.8 Working reference UV radiation illuminance fatigue error (2)
- 4.9 Working reference UV radiation illuminator maximum allowable relative error (2)
- 5 General technical requirements (2)
- 6 Metering device control (3)
- 6.1 Test conditions (3)
- 6.2 Test items (4)
- 6.3 Test method (5)
- 6.4 Processing of test results (10)
- 6.5 Test cycle (10)
- Appendix A Certificate of Verification and Verification Results Page Format (11)
- Appendix B Verification of the original record (12)
- Appendix C Working Basics UV Radiation Illuminance Meter Measurement Uncertainty Evaluation Example (UV-A Band) (14)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Measurement performance requirements (1)
4.1 Spectral response and band division of the device (1)
4.2 Annual change rate of the device (2)
4.3 Operating Baseline Ultraviolet Radiation Illuminance Zero Error (Full Scale FS) (2)
4.4 Working reference UV radiation illuminator long wave response error (2)
4.5 Working Baseline Ultraviolet radiation Illuminance meter cosine characteristics (directional response) (2)
4.6 Working standard Non-linearity error of ultraviolet radiation illuminometer (2)
4.7 Work reference UV radiation illuminometer shift error (2)
4.8 Working reference UV radiation illuminance fatigue error (2)
4.9 Working reference UV radiation illuminator maximum allowable relative error (2)
5 General technical requirements (2)
6 Metering device control (3)
6.1 Test conditions (3)
6.2 Test items (4)
6.3 Test method (5)
6.4 Processing of test results (10)
6.5 Test cycle (10)
Appendix A Certificate of Verification and Verification Results Page Format (11)
Appendix B Verification of the original record (12)
Appendix C Working Basics UV Radiation Illuminance Meter Measurement Uncertainty Evaluation Example (UV-A Band) (14)
Introduction
JJF1001 "General Metrology Terms and Definitions", JJF1032 "Terminology and Definitions of Optical Radiometry" JJF1059.1 "Measurement Uncertainty Assessment and Representation" and JJF1002 "National Metrological Verification Rules" Constitute the basic norms that support the revision of this Code.
Compared with JJG 755-1991, in addition to editorial changes, the main technical changes are as follows.
--- Remove the "SUV-1" in the new procedure, change the UV radiation illuminometer to "working reference UV radiation illuminometer" (See 3);
- on the basis of preserving the four bands of the original procedure (the UVB band of the original procedure is named in this procedure UV-310, UVA2 band named UV-365, UVC band named UV-254), the new International Lighting Commission the three bands proposed by CIE are. UV-A, UV-B and UV-C (see 4.1);
--- Modification of the composition of the UV spectrum radiation illumination comparison device structure diagram (see 6.1.1.3 image 3);
--- change the UV radiation intensity of the work of the reference device annual change rate, the working standard UV radiation illuminator zero Value error, long wave response error, cosine characteristic (directional response) error, nonlinear error, shift error, fatigue Error, relative indication error and other technical indicators (see 4.2 ~ 4.9) and the test method (see 6.3.3 ~ 6.3.10);
- An example of measurement uncertainty assessment has been modified (see Appendix C).
The previous release of this order is.
--- JJG 755-1991.
Verification procedure for the reference device of ultraviolet radiation
1 Scope
This procedure applies to the first test of the UV radiation exposure reference device, subsequent verification and inspection.
2 reference file
This procedure refers to the following documents.
JJG 384 Spectral Radiance Illumination Standard Lamp for dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.
3 Overview
International Council on Illumination CIE will be ultraviolet radiation is divided into UV-A (315nm ~ 400nm), UV-B (280nm ~ 315nm) and UV-C (100nm ~ 280nm) three bands. Due to 100nm ~.200nm UV radiation is strongly absorbed in the air, so for the UV-C band, this procedure only consider.200nm ~ 280nm Wavelength range.
UV Radiation Illumination Work Benchmark Each band consists of three working reference UV radiation illuminometers. jobs the standard UV radiation illuminance meter is the transmission of UV-A, UV-B, UV-C, UV-A1, UV-365, UV-UV-254 and other wavelengths of ultraviolet radiation standard value of the standard instruments, mainly by the detector, amplifier circuit and display instruments composition. Where the detector is typically composed of a photodetector, a filter (band-pass glass or interference filter), and a diffuser group to make. Figure 1 is a schematic diagram of the general composition of the operating reference UV radiation illuminometer detector, whose magnitude is measured by spectral Radiometric comparison of alternative methods Trace to spectral radiance Illumination national benchmarks.
Figure 1 Schematic diagram of the general composition of the working reference ultraviolet radiation illuminance detector
4 Measurement performance requirements
4.1 Spectral response and band division of the device UV-A band. 315nm ~ 400nm, peak wavelength lambdap = 365nm ± 5nm UV-B band. 280nm ~ 315nm, peak wavelength lambdap = 297nm ± 5nm UV-C band..200nm ~ 280nm, peak wavelength lambdap = 254nm ± 5nm UV-A1 band. 320nm ~ 390nm, peak wavelength lambdap = 365nm ± 5nm UV-365 band. peak wavelength lambdap = 365nm ± 2nm, peak half height width deltalambda <= 10nm
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download JJG 755-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 755-2015
$295.00