JJG 690-2003Verification Regulation of High Insulation Resistance Meters (English PDF)
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for JJG 690-2003 in 30 minutes.
Issued by
The General Administration of Quality Supervision, Inspection and Quarantine issued, This verification procedure was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 23,.2003.
Level / Type
National · Mandatory
Issue date
September 23, 2003
Implementation date
March 23, 2004
Scope
JJG 690-2003 (Verification Regulation of High Insulation Resistance Meters) is available as an English-translated PDF.
JJG 690-2003 — This standard applies to a test machine with the amplifier, the DC rated working voltage not exceeding 1000V, direct measurement instructions 1000M�� digital and analog resistance above indicate a high insulation resistance meter (hereinafter referred to as the impedance meter) of the first test, follow-up tests and the use of the test. This procedure does not apply to insulation resistance meter, ohm meter test.
Found what you need?
Document preview — JJG 690-2003
National Standard of the People's Republic of China
- Classification
- A 55
- Replacing
- JJG 690-1990
Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This verification procedure was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 23,.2003.
Contents
- 1 Scope (1)
- 2 Citations (1)
- 3 Noun terms (1)
- 4 Overview (1)
- 4.1 Composition of high resistance meter (1)
- 4.2 Calculation formula for measuring resistance with high resistance meter (1)
- 4.3 Type of high resistance meter (2)
- 5 Metrological performance requirements (2)
- 5.1 Basic error of resistance measurement (2)
- 5.2 Accuracy level (2)
- 5.3 Terminal voltage (3)
- 5.4 Repeatability (3)
- 6 General technical requirements (3)
- 6.1 Appearance (3)
- 6.2 Marks (3)
- 6.3 Display (3)
- 6.4 Resolution (3)
- 6.5 Terminal voltage ripple content (4)
- 6.6 Insulation resistance (4)
- 6.7 Dielectric strength (4)
- 7 Measuring instrument control (4)
- 7.1 Verification conditions (4)
- 7.2 Verification project (4)
- 7.3 Verification method (5)
- 7.4 Processing of verification results (10)
- 7.5 Verification cycle (11)
- Appendix A Basic Structure of High Resistance Meter (12)
- Appendix B Verification of the basic error of the high resistance meter by voltage compensation method (15)
- Appendix C Verification of the basic error of high resistance meter by current and voltage method (17)
- Appendix D High Resistance Meter Verification Certificate Page Format (19)
- Appendix E High-resistance meter verification result notice page format (20)
- Appendix F High Resistance Meter Verification Original Record (21)
1 Scope (1)
2 Citations (1)
3 Noun terms (1)
4 Overview (1)
4.1 Composition of high resistance meter (1)
4.2 Calculation formula for measuring resistance with high resistance meter (1)
4.3 Type of high resistance meter (2)
5 Metrological performance requirements (2)
5.1 Basic error of resistance measurement (2)
5.2 Accuracy level (2)
5.3 Terminal voltage (3)
5.4 Repeatability (3)
6 General technical requirements (3)
6.1 Appearance (3)
6.2 Marks (3)
6.3 Display (3)
6.4 Resolution (3)
6.5 Terminal voltage ripple content (4)
6.6 Insulation resistance (4)
6.7 Dielectric strength (4)
7 Measuring instrument control (4)
7.1 Verification conditions (4)
7.2 Verification project (4)
7.3 Verification method (5)
7.4 Processing of verification results (10)
7.5 Verification cycle (11)
Appendix A Basic Structure of High Resistance Meter (12)
Appendix B Verification of the basic error of the high resistance meter by voltage compensation method (15)
Appendix C Verification of the basic error of high resistance meter by current and voltage method (17)
Appendix D High Resistance Meter Verification Certificate Page Format (19)
Appendix E High-resistance meter verification result notice page format (20)
Appendix F High Resistance Meter Verification Original Record (21)
High insulation resistance measuring instrument (high resistance meter) verification procedure
1 Scope
This procedure is applicable to the test amplifier in the machine, its DC rated working voltage is not more than 1000V, and can be directly measured.
Digital indication and analog indication high insulation resistance measuring instrument with a capacity of 1000Mohm or more (hereinafter referred to as high resistance meter) First verification, follow-up verification and inspection in use.
This procedure does not apply to the verification of insulation resistance meters and ohmmeters. This procedure does not involve the inspection of high resistance meter measuring electrodes.
set.
2 Citations
This procedure refers to the following documents.
JJF1001-1998 General Terms and Definitions JJF1059-1999 "Measurement and Expression of Measurement Uncertainty" GB/T 13983-92 "Basic Terminology of Instrumentation" GB 4793-1995 "Safety requirements for electrical equipment for measurement, control and laboratory use" GB/T 14913-94 "DC digital voltmeter and DC analog-to-digital converter" Note. When using this procedure, care should be taken to use the current valid version of the above cited documents.
3 noun terms
3.1 High insulation resistance measuring instrument Direct measurement of insulation resistance values of insulating materials, general electrical products and electronic components, and high value resistors Electrical measuring instrument for resistance values. There are test amplifiers and indicating instruments in the instrument, and the DC rated working voltage is not large.
At 1000V.
3.2 Rated voltage
The nominal value of the output voltage at the open end of the measuring terminal.
3.3 terminal voltage Measure the measured value of the output voltage when the terminal is in the open state.
4 Overview
4.1 Composition of high resistance meter A high resistance meter is generally composed of three parts.
a) a DC voltage source;
b) a high input impedance DC amplifier;
c) Indicate the meter.
See Appendix A for the basic structure and principles.
4.2 Calculation formula for measuring resistance with high resistance meter.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
How to Download JJG 690-2003
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1201-2024 — Digital Tyre Pressure Gauges
JJG 1202-2024 — Long Distance Transmissible Pressure Gauges
JJG 746-2024 — Ultrasonic Flaw Detectors
Secure payment via Stripe
Payments accepted
JJG 690-2003