JJG 678-2007Verification Regulation of Catalysis Combustion Type Methane Measuring Device (English PDF)
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJG 678-2007 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
August 21, 2007
Implementation date
February 21, 2008
Scope
JJG 678-2007 (Verification Regulation of Catalysis Combustion Type Methane Measuring Device) is available as an English-translated PDF.
JJG 678-2007 — This standard applies to mines with a loss of catalytic combustion of methane detector initial verification, testing and use of follow-up inspection.
Found what you need?
Document preview — JJG 678-2007
National Standard of the People's Republic of China
- ICS
- 17.120
- Classification
- A 61
- Replacing
- JJG 678-1996
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- 1 Scope (1)
- 2 Overview (1)
- 3 Metering performance requirements (1)
- 3.1 Indication error (1)
- 3.2 Alarm error (1)
- 3.3 Response Time (1)
- 3.4 Drift (1)
- 3.5 Alarm sound level and signal strength (1)
- 3.6 Load characteristics (1)
- 4 General Requirements (2)
- 4.1 Appearance (2)
- 4.2 Identification and Accessories (2)
- 4.3 Energizing check (2)
- 5 Control of measuring instruments (2)
- 5.1 Verification Conditions (2)
- 5.2 Verification Project (3)
- 5.3 Verification Methods (3)
- 5.4 Verification Results Processing (5)
- 5.5 Test cycle (5)
- Appendix A Test certificate-page format (6)
- Appendix B Test results in the notice page format (7)
- Appendix C Portable instrument calibration original record format (8)
- Appendix D Stationary instrument calibration original record format (9)
1 Scope (1)
2 Overview (1)
3 Metering performance requirements (1)
3.1 Indication error (1)
3.2 Alarm error (1)
3.3 Response Time (1)
3.4 Drift (1)
3.5 Alarm sound level and signal strength (1)
3.6 Load characteristics (1)
4 General Requirements (2)
4.1 Appearance (2)
4.2 Identification and Accessories (2)
4.3 Energizing check (2)
5 Control of measuring instruments (2)
5.1 Verification Conditions (2)
5.2 Verification Project (3)
5.3 Verification Methods (3)
5.4 Verification Results Processing (5)
5.5 Test cycle (5)
Appendix A test certificate-page format (6)
Appendix B test results in the notice page format (7)
Appendix C portable instrument calibration original record format (8)
Appendix D stationary instrument calibration original record format (9)
Catalytic combustion of methane detector test procedures
1 Scope
The order applies to mines with catalytic combustion of methane detector (hereinafter referred to as equipment) initial verification, subsequent verification and in-service inspection.
2 Overview
Instrument carrier thermal catalytic combustion principle, by a carrier catalytic element constituting the measuring bridge, when the instrument environment the presence of methane gas due to methane in the catalytic element surface flameless combustion, catalytic carrier resistance detection element Value changes, the bridge imbalance signal to produce an output signal magnitude and linearly proportional to the methane content in order to achieve Methane content detection and alarm.
Catalytic combustion of methane detector has two types of portable and fixed, stationary methane detector, also known as methane Biography Sensors. For measuring methane content in mine and alarm, when the methane concentration reaches the alarm set point, the instrument emits sound, Light alarm signal.
3 metering performance requirements
3.1 Indication error Indication error expressed in absolute error. Instrument under specified operating conditions, the differential value of the maximum value and the standard should not be Than specified in Table 1.
Table 1 shows the error
Measurement range /% CH4 0 ~ 4 Break /% CH4 0<=X<=1 1 \u003cX<=2 2\u003cX<=4 the maximum permissible error /% CH4 ± 0.10 ± 0.20 ± 0.30
3.2 Alarm error
Instrument alarm differential value and alarm set value should not exceed ± 0.10% CH4.
3.3 Response Time
Diffusion sampling instrument shall not exceed 20s, inhaled sampling instruments should not exceed 10s.
3.4 Drift
Instrument drift includes zero drift and span drift. Zero drift should not exceed ± 0.10% CH4, span drift shall not exceed ± 0.20% CH4.
3.5 alarm sound level and signal strength the portable instrument alarm sound level intensity should not be less than 75dB (A), fixed instrument alarm sound level intensity should not be less than 80dB (A). Alarm signal light in a dark environment at 20m should be clearly visible.
3.6 load characteristics
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJG 678-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 678-2007
$165.00