JJG 571-2004Verification Regulation of Reading Microscope and Measuring Microscope (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for JJG 571-2004 in 30 minutes.

Issued by

The General Administration of Quality Supervision, Inspection and Quarantine issued, This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 21,.2004, and

Level / Type

National · Mandatory

Issue date

September 21, 2004

Implementation date

March 21, 2005

Scope

JJG 571-2004 (Verification Regulation of Reading Microscope and Measuring Microscope) is available as an English-translated PDF.

JJG 571-2004 — This standard applies to indexing is not greater than 0. 01mm, 8mm measuring range upper limit to the reading microscope, and dividing the value is not greater than 0.

Found what you need?

Document preview — JJG 571-2004

National Standard of the People's Republic of China

ICS
17.040
Classification
A 52
Replacing
JJG 571-1988% JJG 904-1996

Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 21,.2004, and

Contents

  • 1 Scope (1)
  • 2 Citations (1)
  • 3 Overview (1)
  • 4 Metrological performance requirements (2)
  • 4.1 Displacement caused by the radial force of the circular table (2)
  • 4.2 Parallelism of the movement direction of the glass table and the longitudinal and lateral slides (2)
  • 4.3 Straightness of vertical and horizontal slide movement (2)
  • 4.4 Mutual verticality of vertical and horizontal slide movement (2)
  • 4.5 The verticality of the microscope lifting direction to the glass table (2)
  • 4.6 Indication error of round table (2)
  • 4.7 Magnification error of the microscope (2)
  • 4.8 Return error (2)
  • 5 General technical requirements (3)
  • 5.1 Appearance (3)
  • 5.2 Interaction of various parts (3)
  • 5.3 Relative position between the lines of the microscope (3)
  • 5.4 Prism seat rotation causes image displacement (4)
  • 5.5 Coincidence between the center of the spiral reticle and the center of rotation (4)
  • 6 Measuring instrument control (4)
  • 6.1 Verification conditions (4)
  • 6.2 Verification project (4)
  • 6.3 Verification method (4)
  • 6.4 Processing of verification results (9)
  • 6.5 Verification period (9)
  • Appendix A Analysis of the Uncertainty of the Results of the Errors in the Reading Microscope (10)
  • Appendix B Uncertainty Analysis of Measurement Results of Measurement Microscope Errors (12)
  • Appendix C Verification device for verifying the coincidence of the spiral dividing center with its center of rotation (14)
  • Appendix D Verification certificate and verification result notice page format (15)

1 Scope (1)

2 Citations (1)

3 Overview (1)

4 Metrological performance requirements (2)

4.1 Displacement caused by the radial force of the circular table (2)

4.2 Parallelism of the movement direction of the glass table and the longitudinal and lateral slides (2)

4.3 Straightness of vertical and horizontal slide movement (2)

4.4 Mutual verticality of vertical and horizontal slide movement (2)

4.5 The verticality of the microscope lifting direction to the glass table (2)

4.6 Indication error of round table (2)

4.7 Magnification error of the microscope (2)

4.8 Return error (2)

5 General technical requirements (3)

5.1 Appearance (3)

5.2 Interaction of various parts (3)

5.3 Relative position between the lines of the microscope (3)

5.4 Prism seat rotation causes image displacement (4)

5.5 Coincidence between the center of the spiral reticle and the center of rotation (4)

6 Measuring instrument control (4)

6.1 Verification conditions (4)

6.2 Verification project (4)

6.3 Verification method (4)

6.4 Processing of verification results (9)

6.5 Verification period (9)

Appendix A Analysis of the Uncertainty of the Results of the Errors in the Reading Microscope (10)

Appendix B Uncertainty Analysis of Measurement Results of Measurement Microscope Errors (12)

Appendix C Verification device for verifying the coincidence of the spiral dividing center with its center of rotation (14)

Appendix D Verification certificate and verification result notice page format (15)

Reading and measuring microscope verification procedures

1 Scope

This procedure is applicable to reading microscopes with a division value not greater than 0.01 mm and an upper measurement range up to 8 mm, and the division value is not more than 0.01mm, and the measurement range is. measurement in the longitudinal direction (0~50) mm and the lateral direction (0~13) mm.

The first verification, subsequent verification and in-use inspection of the microscope.

2 Citations

This procedure refers to the following documents.

JJF1001-1998 General measurement terms and definitions JJF1059-1999 Measurement Uncertainty Evaluation and Representation JJF1094-2002 Measuring instrument characteristic evaluation JB/T 2369-1993 reading microscope JB/T 9339-1999 Measuring microscope when using this procedure, care should be taken to use the current valid version of the above cited documents.

3 Overview

Reading microscopes and measuring microscopes (hereinafter referred to as microscopes) are optical mechanical length measuring instruments, readings the microscope is mainly used as the aiming and positioning reading device in the length measuring instrument, and can also be used for the scribe line width, spacing, etc.

Measurement of the length; the main purpose of the measuring microscope is to measure the part by the image method in Cartesian or polar coordinates.

Shape size. The shape of the reading microscope is shown in Figure 1, Figure 2, Figure 3. The shape of the measuring microscope is shown in Figure 4.

Shown.

Figure 1 One of the outlines of the reading microscope

1-objective lens; 2-measuring differential scrimmage box;

3-eyepiece; 4-micrometer knob; 5-light

Figure 2 Figure 2 of the reading microscope

1-objective lens; 2-micrometer knob; 3-eyepiece;

4-measuring differential scrimmage box; 5-zero adjustment knob; 6-light

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download JJG 571-2004

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 571-2004

$255.00