Scope

JJG 537-2006 (Verification Regulation of Fluorescence Spectrophotometer) is available as an English-translated PDF.

JJG 537-2006 — This standard applies to fluorescence spectrophotometer initial verification, testing and use of follow-up inspection.

Found what you need?

Document preview — JJG 537-2006

National Standard of the People's Republic of China

ICS
17.180
Classification
A 61
Replacing
JJG 537-1988; JJG 538-1988

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metrological performance requirements (1)
  • 3.1 Wavelength indication error and repeatability (1)
  • 3.2 Detection limit (2)
  • 3.3 Measurement linearity (2)
  • 3.4 Fluorescence spectrum peak intensity repeatability (2)
  • 3.5 Stability (2)
  • 4 General technical requirements (2)
  • 4.1 Appearance and preliminary inspection (2)
  • 4.2 Insulation resistance (2)
  • 5 Measuring instrument control (2)
  • 5.1 Verification conditions (2)
  • 5.2 Verification project (3)
  • 5.3 Verification method (3)
  • 5.4 Processing of verification results (7)
  • 5.5 Verification cycle (7)
  • Appendix A Preparation of working standard solution for verification (8)
  • Appendix B Measurement method of mercury lamp line (10)
  • Appendix C Measurement of Fluorescent Pool Completeness (11)
  • Appendix D Least Squares Calculation Formula (12)
  • Appendix E Fluorescence Spectrophotometer Verification Record Format (13)
  • Appendix F Verification Certificate Back Format (15)

1 Scope (1)

2 Overview (1)

3 Metrological performance requirements (1)

3.1 Wavelength indication error and repeatability (1)

3.2 Detection limit (2)

3.3 Measurement linearity (2)

3.4 Fluorescence spectrum peak intensity repeatability (2)

3.5 Stability (2)

4 General technical requirements (2)

4.1 Appearance and preliminary inspection (2)

4.2 Insulation resistance (2)

5 Measuring instrument control (2)

5.1 Verification conditions (2)

5.2 Verification project (3)

5.3 Verification method (3)

5.4 Processing of verification results (7)

5.5 Verification cycle (7)

Appendix A Preparation of working standard solution for verification (8)

Appendix B Measurement method of mercury lamp line (10)

Appendix C Measurement of Fluorescent Pool Completeness (11)

Appendix D Least Squares Calculation Formula (12)

Appendix E Fluorescence Spectrophotometer Verification Record Format (13)

Appendix F Verification Certificate Back Format (15)

Fluorescence spectrophotometer verification procedure

1 Scope

This procedure applies to the first verification, subsequent verification and in-use inspection of the fluorescence spectrophotometer.

2 Overview

When some substances are excited by light, they emit light that is slightly longer than the wavelength of the light. This light is called fluorescing.

Light. The fluorescence intensity has the following relationship with the concentration of the substance.

F=k'PhiI0(1-e-epsilonLc) where. F---fluorescence intensity;

K'---instrument constant;

I0---excitation light intensity;

epsilon---the molar absorption coefficient of the fluorescent substance;

L---the thickness of the liquid layer of the fluorescent substance;

c---concentration of the fluorescent substance;

Phi---fluorescence quantum efficiency.

For a given substance, when the wavelength and intensity of the excitation light are fixed, the thickness of the liquid layer is fixed, and the concentration of the solution is higher.

When low, the fluorescence intensity has a simple relationship with the concentration c of the fluorescent substance.

F=kc

Fluorescence spectrophotometer (hereinafter referred to as the instrument) is based on the above principle, to determine the substance that can emit fluorescence Analytical instrument for qualitative and quantitative measurement.

The instrument is mainly composed of a light source system, an excitation monochromator system, a sample chamber, a launch monochromator system, a detector system, and the data processing system is composed.

The monochromators of the instrument can be divided into two categories. Class A is a dispersive monochromator; Class B is a filter monochromator.

3 Metrological performance requirements

3.1 Wavelength indication error and repeatability

3.1.1 Class A monochromator wavelength indication error limits and wavelength repeatability shall meet the following requirements.

Wavelength indication error limit. better than ±2.0nm;

Wavelength repeatability. <= 1.0 nm.

3.1.2 Class B Monochromator Filter Light Transmission Characteristics the nominal value of the glass filter and interference filter of the class B monochromator configuration shall meet the following requirements.

Glass filter. nominal value ± 10 nm;

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

Referenced standards

How to Download JJG 537-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 537-2006

$494.00