Scope
JJG 353-2006 (Verification Regulation of 633nm Frequency Stabilized Lasers) is available as an English-translated PDF.
JJG 353-2006 — This standard applies to different types of 633nm laser frequency stabilization initial verification and follow-up examination. For a variety of frequency stabilization of the laser output wavelength 633nm wavelength in vacuum (frequency) values ??traceability and different sampling interval frequency stability measurements.
Found what you need?
Document preview — JJG 353-2006
National Standard of the People's Republic of China
- ICS
- 17.040
- Classification
- A 52
- Replacing
- JJG 353-1994
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- 1 Scope (1)
- 2 Citations (1)
- 3 Overview of the frequency stabilization principle of the 633nm stabilized laser detected (2)
- 4 Metrological performance requirements (2)
- 4.1 Average frequency value and vacuum wavelength value of the 633nm stabilized laser detected (2)
- 4.2 Relatively Extended Uncertainty of 633nm Stabilized Laser Wavelength (2)
- 4.3 Relative frequency stability (3)
- 5 General technical requirements (3)
- 5.1 Signs (3)
- 5.2 Technical Information (3)
- 5.3 Structure and appearance (3)
- 5.4 Function keys (3)
- 6 Measuring instrument control (3)
- 6.1 Verification conditions (3)
- 6.2 Verification project (4)
- 6.3 Verification method (4)
- 6.4 Processing of verification results (7)
- 6.5 Verification period (7)
- Appendix A Verifying the Original Record Format (8)
- Appendix B Verification Certificate (inside page) format (9)
- Appendix C Format of the verification result (inside page) format (10)
- Appendix D Introduction to Various Stabilized Lasers (11)
- Appendix E Wavelength Relative Expansion Uncertainty of Different Interferometer Sources (12)
- Appendix F Relative Depth of Lasers in Lamb Depression (13)
1 Scope (1)
2 Citations (1)
3 Overview of the frequency stabilization principle of the 633nm stabilized laser detected (2)
4 Metrological performance requirements (2)
4.1 Average frequency value and vacuum wavelength value of the 633nm stabilized laser detected (2)
4.2 Relatively Extended Uncertainty of 633nm Stabilized Laser Wavelength (2)
4.3 Relative frequency stability (3)
5 General technical requirements (3)
5.1 Signs (3)
5.2 Technical Information (3)
5.3 Structure and appearance (3)
5.4 Function keys (3)
6 Measuring instrument control (3)
6.1 Verification conditions (3)
6.2 Verification project (4)
6.3 Verification method (4)
6.4 Processing of verification results (7)
6.5 Verification period (7)
Appendix A Verifying the Original Record Format (8)
Appendix B Verification Certificate (inside page) format (9)
Appendix C Format of the verification result (inside page) format (10)
Appendix D Introduction to Various Stabilized Lasers (11)
Appendix E Wavelength Relative Expansion Uncertainty of Different Interferometer Sources (12)
Appendix F Relative Depth of Lasers in Lamb Depression (13)
633nm frequency stabilization laser verification procedure Meter is the basic length unit in the International System of Units (SI). The 17th International Metrology Conference in October 1983 (CGPM) passed the current m definition, ie "meter is light in vacuum, at intervals of 1/299,792,458 seconds the length of the internal propagation". At the same time, the original m definition was abolished. There are three methods for recurring the current m definition.
---l=c·t, that is, first measure the time t required for the plane electromagnetic wave to propagate over the distance l in the vacuum, and then c·t can find the measured length l;
---lambda=cf
, that is, measuring the frequency f of the plane electromagnetic wave, and then by cf Find the vacuum wavelength lambda and use lambda as the length standard;
--- Directly refer to the 12 laser radiation lines recommended by the International Metrology Commission (see the cited literature for details) Vacuum wavelength value or frequency value and used according to the given uncertainty.
This procedure uses the third method described above and selects 633nm stabilized on the saturated absorption line of iodine molecules.
The He-Ne laser wavelength is used as a measurement standard.
In.1992, the International Metrology Conference specified a relative standard uncertainty of 2.5×10-11 for the 633 nm laser wavelength reference.
The laser interferometer as the base standard of the length measurement in the length measurement is calculated according to the emission wavelength of the light source.
Length value. Various frequency-stabilized lasers as interferometer light sources have stable output wavelength (frequency) characteristics.
It is the basic working condition to ensure the normal operation of the interferometer.
1 Scope
This procedure applies to the first verification and subsequent verification of different types of frequency-stabilized 633 nm lasers. Suitable for all kinds of the trace value of the vacuum wavelength (frequency) value of the output wavelength of the stabilized 633 nm laser and the different sampling intervals Measurement of frequency stability.
The qualified 633nm frequency-stabilized laser can be used as the interferometer source of the standard equipment for national level, Provincial (department) level and interferometric measurement systems for various verification and calibration devices of enterprises and institutions.
2 Citations
This procedure refers to the following documents.
DocumentsConcerningtheNewDefinitionoftheMeter, Metrologia, 19 (1984) 163.
(the document of the definition of the new meter, the measurement, 19 volumes (1984) 163 pages.) MiseenPratiqueoftheDefinitionoftheMetre (1992), Metrologia, 30 (1994) 523.
(Implementation method of the definition of the meter (1992), measurement, 30 volumes (1994) 523 pages.) PracticalRealization of the Definition of the Metre (1997), Metrologia, 36 (1997) 211.
(Implementation of the definition of meters (1997), Measurement, Vol. 36 (1997) 211.)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 1983 pages — is available in the English PDF.
How to Download JJG 353-2006
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1201-2024 — Digital Tyre Pressure Gauges
JJG 1202-2024 — Long Distance Transmissible Pressure Gauges
JJG 746-2024 — Ultrasonic Flaw Detectors
Secure payment via Stripe
Payments accepted
JJG 353-2006
$444.00