Scope

JJG 349-2014 (Verification Regulation of the Universal Counters) is available as an English-translated PDF.

JJG 349-2014 — This Standard applies to the measurement frequency range of 18 GHz or less universal counter initial verification, use and subsequent verification check.

Found what you need?

Document preview — JJG 349-2014

National Standard of the People's Republic of China

ICS
17.080
Classification
A 57
Replacing
JJG 349-2001

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terms (1)
  • 4 Overview (1)
  • 5 Metering performance requirements (1)
  • 5.1 Input characteristics (1)
  • 5.2 Frequency Measurement maximum permissible error (2)
  • 5.3 The maximum permissible error measurement period (2)
  • 5.4 Time interval measuring the maximum permissible error (2)

1 Scope (1)

2 References (1)

3 Terms (1)

4 Overview (1)

5 Metering performance requirements (1)

5.1 Input characteristics (1)

5.2 Frequency Measurement maximum permissible error (2)

5.3 The maximum permissible error measurement period (2)

5.4 Time interval measuring the maximum permissible error (2)

Built-in time base oscillator 5.5 (2)

6 General Requirements (2)

7 Control of measuring instruments (3)

7.1 Test conditions (3)

7.2 Test items and test methods (3)

7.3 Verification Results Processing (7)

7.4 Test cycle (7)

Appendix A common counter calibration certificate/test results in the notice page format (8)

Appendix B universal counter calibration certificate test results page format (9)

Appendix C Universal counter notice test results test results page format (11)

Appendix D general-purpose counter the original record test data page format (13)

Introduction

This procedure is carried out revision of JJG 349-2001. Compared with JJG 349-2001, in addition to editorial changes outside the main technical changes are as follows.

--- Increase the frequency measurement limit, the lower limit of the measurement period and the time interval measurement limit;

--- New introduction, the term content, effective resolution proposed concept;

--- Modify, supplement the content requirements for performance measurement;

--- Refine and clarify the test conditions and test methods;

--- Modify, add cycle measurement error test methods;

--- Supplementary time interval measurement error in the single-channel pulse width test method;

--- New calibration certificate/test results notice page format, page format calibration certificate test results, test knot If the notice of test results page format, the original record test data page format.

The regulations previously issued as follows.

--- JJG 349-2001.

Universal Counter test procedures

1 Scope

The order applies to the measurement frequency range of 18GHz or less universal counter initial verification, and follow-up Use checks.

2. References

JJG 180 electronic measuring instruments within the quartz oscillator JJG 181 quartz crystal frequency standard JJG 292 rubidium atomic frequency standard JJG 841 microwave frequency counter for dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.

3 Terms

Effective resolution Instrument displays measurement results in a stable, positive digit represents the lowest value.

4 Overview

Universal Counter basic principle is suitable logic circuit (gate time) within a predetermined standard time the cumulative number of oscillations measured input signal, or in the time interval measured cumulative standard time (time base) signal a Number, frequency, and period measurement time interval; basic circuit by the input channel when generating transform unit group, Main door, a control unit, a display unit and other components and counting; with a variety of measurement functions, including the frequency, period, and Time interval measurement, usually including frequency than at any time interval and the cumulative number of pulses counting measure Features.

5 metering performance requirements

5.1 Input characteristics Input characteristics are shown in Table 1.

Table 1 Input characteristics

Measurement of performance Measurement function Frequency periodic time interval Measuring range (0 ~ 1) GHz (1 ~ 18) GHz 1ns ~ 10ns 10ns ~ 100s 2ns ~ 105s Input Sensitivity (RMS) (10 ~ 300) mV (-33 ~ -20) dBm (-33 ~ -20) dBm (10 ~ 300) mV ---

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download JJG 349-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 349-2014

$295.00