Valid

JJG 246-2005Verification Regulation of Standard Lamp of Luminous Intensity (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for JJG 246-2005 in 30 minutes.

Issued by

The General Administration of Quality Supervision, Inspection and Quarantine issued, This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 3,.2005, and

Level / Type

National · Mandatory

Issue date

March 3, 2005

Implementation date

September 3, 2005

Scope

JJG 246-2005 (Verification Regulation of Standard Lamp of Luminous Intensity) is available as an English-translated PDF.

JJG 246-2005 — This standard applies to luminous intensity standard lamp (referred to standard lamps) for initial verification, testing and use of follow-up inspection.

Found what you need?

Document preview — JJG 246-2005

National Standard of the People's Republic of China

ICS
17.180
Classification
A 60
Replacing
JJG 246-1991; JJG 732-1991

Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 3,.2005, and

Contents

  • 1 Scope (1)
  • 2 Citations (1)
  • 3 Overview (1)
  • 4 Metrology performance requirements (1)
  • 4.1 Luminous intensity standard lamp stability (1)
  • 4.2 Luminous intensity standard lamp angle characteristics (1)
  • 4.3 Annual rate of change of standard lamp luminous intensity value (1)
  • 4.4 Uncertainty of the expansion of the standard lamp luminous intensity value (2)
  • 5 General technical requirements (2)
  • 5.1 Appearance (2)
  • 5.2 Identification (2)
  • 6 Measuring instrument control (2)
  • 6.1 Verification conditions (2)
  • 6.2 Verification project (3)
  • 6.3 Verification method (3)
  • 6.4 Processing of verification results (8)
  • 6.5 Verification period (8)
  • Appendix A Photoelectric parameters of domestic luminous intensity standard lamps (9)
  • Appendix B Determination of horizontal and vertical angle characteristics (10)
  • Appendix C Calculation Method of Measurement System Unstable Correction Coefficient (11)
  • Appendix D Verification of the non-linearity of the photometer (12)
  • Appendix E Calculation Method of Mismatch Correction Coefficient (13)
  • Appendix F Example of Uncertainty Evaluation (14)
  • Appendix G Verification of the original record of the standard record of luminous intensity standard lamp by equidistance method (17)
  • Appendix H Luminous Intensity Standard Lamp Verification Certificate and Verification Result Notice (inside page) format (23)

1 Scope (1)

2 Citations (1)

3 Overview (1)

4 Metrology performance requirements (1)

4.1 Luminous intensity standard lamp stability (1)

4.2 Luminous intensity standard lamp angle characteristics (1)

4.3 Annual rate of change of standard lamp luminous intensity value (1)

4.4 Uncertainty of the expansion of the standard lamp luminous intensity value (2)

5 General technical requirements (2)

5.1 Appearance (2)

5.2 Identification (2)

6 Measuring instrument control (2)

6.1 Verification conditions (2)

6.2 Verification project (3)

6.3 Verification method (3)

6.4 Processing of verification results (8)

6.5 Verification period (8)

Appendix A Photoelectric parameters of domestic luminous intensity standard lamps (9)

Appendix B Determination of horizontal and vertical angle characteristics (10)

Appendix C Calculation Method of Measurement System Unstable Correction Coefficient (11)

Appendix D Verification of the non-linearity of the photometer (12)

Appendix E Calculation Method of Mismatch Correction Coefficient (13)

Appendix F Example of Uncertainty Evaluation (14)

Appendix G Verification of the original record of the standard record of luminous intensity standard lamp by equidistance method (17)

Appendix H Luminous Intensity Standard Lamp Verification Certificate and Verification Result Notice (inside page) format (23)

Luminous intensity standard lamp verification procedure

1 Scope

This procedure is applicable to the first verification, subsequent verification and in-use inspection of luminous intensity standard lamps (referred to as standard lamps).

Test. The requirements for metering performance in standard lamp qualification can be referred to.

2 Citations

JJG 213-2003 "Distribution (color) temperature standard lamp" when using this procedure, care should be taken to use the current valid version of the above cited documents.

3 Overview

Luminous intensity standard lamps are measuring instruments that maintain and transmit a unit of luminous intensity. It is made to specific requirements an incandescent lamp with stable illuminating characteristics, the illuminants are arranged in a plane, the shape of the bulb and the additional aperture are sought to avoid or Reduce stray light. Such a lamp has a uniform light distribution in the measurement direction and has excellent reproducibility of magnitude.

4 Metrological performance requirements

4.1 Luminous intensity standard lamp stability Luminous intensity standard lamps must be aged according to relevant regulations before leaving the factory. The stability of the lamp after aging should be achieved.

When the test current (see Appendix A) is ignited for 4h, the lamp terminal voltage change of the vacuum lamp should be less than 0.15%, and the lamp end of the gas lamp the voltage change should be less than 0.25%.

4.2 Luminous intensity standard lamp angle characteristics Luminous intensity standard lamps should have good horizontal and vertical angle characteristics, and the lamp should be rotated ±1.5° in the horizontal direction.

When the luminous intensity changes by no more than 0.6%. When the bulb is rotated ±1.0° in the vertical direction, the luminous intensity does not change more than 0.6%.

4.3 Annual rate of change of standard lamp luminous intensity value the luminous intensity standard lamp for the first inspection is not rated. Year after the re-examination, the year according to the luminous intensity of the lamp the rate of change and the level of the standard lamp used for calibration of this lamp are rated as specified in Table 1.

Table 1 Annual change rate of luminous intensity of lamps at each level

The annual change rate of the luminous intensity of the standard lamp level to be tested should be less than Sub Benchmark Work Benchmark 0.5% Work benchmark level 0.7% Level 1 and Level 1.2% the annual rate of change of the luminous intensity of a standard lamp is calculated by the following formula.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

How to Download JJG 246-2005

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 246-2005

$385.00