JJG 2095-2012Verification Scheme of Measuring Instruments for Air-Kerma of (10-60) kV X-Ray (English PDF)
(10~60)kV X射线空气比释动能计量器具
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for JJG 2095-2012 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
June 18, 2012
Implementation date
December 18, 2012
Scope
JJG 2095-2012 is the English-translated version of (10~60)kV X射线空气比释动能计量器具.
JJG 2095-2012 - This standard applies to (10-60) kV X-ray air kerma verification of measuring instruments.
Found what you need?
Document preview — JJG 2095-2012
National Standard of the People's Republic of China
- ICS
- 17.240
Contents
- 1 Scope (1)
- 2 Baseline measurement (1)
- 2.1 (10 ~ 60) kVX ray air kerma national baseline (1)
- 2.2 (10 ~ 60) other standard device kVX ray air kerma passing reference (1)
- 3 Measurement standards (1)
- 3.1 X-ray standard therapeutic levels apparatus (1)
- 3.2 Standard X-ray diagnosis apparatus (2)
- 3.3 X-ray standard level of protection means (2)
- 3.4 Environmental level X-ray standard device (2)
- 4 Working measuring instruments (2)
1 Scope (1)
2 Baseline measurement (1)
2.1 (10 ~ 60) kVX ray air kerma national baseline (1) 2.2 (10 ~ 60) other standard device kVX ray air kerma passing reference (1)
3 Measurement standards (1)
3.1 X-ray standard therapeutic levels apparatus (1)
3.2 Standard X-ray diagnosis apparatus (2)
3.3 X-ray standard level of protection means (2)
3.4 Environmental level X-ray standard device (2)
4 Working measuring instruments (2)
Therapeutic dose levels of 4.1 meter (2)
4.2 Medical X-ray radiation therapy (2)
4.3 X-ray detection machine (3)
4.4 X-ray measuring instruments (3)
4.5 Diagnosis dosimeter (3)
4.6 Medical Diagnostic X-ray radiation source (3)
4.7 Radiation Protection X-ray air kerma (rate) or dose equivalent (rate) measurement and alarm instruments (3)
4.8 Environmental Monitoring X-ray air Shibi kinetic (rate) measuring instruments (3)
5 (10 ~ 60) kVX ray air kerma Measuring Instruments System Tables Diagram (3) (10 ~ 60) kVX ray Air kerma measuring instruments Verification System
1 Scope
The verification system applicable to (10 to 60) Verification kVX ray air Shibi kinetic energy measuring instruments. It provides the (10 ~ 60) kVX ray air kerma national baseline purposes, including a full set of basic benchmark gauge Tools, metrology parameters, by means of a standard transfer air kerma values to the work program of measuring instruments, and to indicate its Uncertainty and verification methods.
2 baseline measurement (10 ~ 60) kVX ray air kerma by the reference measuring instruments and reference ionization chamber system (10 to 60) kVX ray radiation device components.
2.1 (10 ~ 60) kVX ray air kerma national benchmark 2.1.1 (10 ~ 60) kVX ray air kerma national benchmarks for reproduction and preservation of air kerma (Gy) of value, and by means of radiation to a standard of measuring instruments, measuring instruments work transfer unit value, to ensure National (10 ~ 60) kVX ray air kerma values of unity, the measurement range than the air kerma rate is (0.01 ~ 0.1) Gy/min.
2.1.2 (10 ~ 60) kVX ray air kerma national benchmarks for the free-air ionization chamber system, including flat Andante free-air ionization chamber and ionization charge measurement system. Ionization charge measurement system parallel plate free-air ionization the output of the charge chamber. Air kerma reference in (10 to 60) the radiation field kVX ray radiation device reproducing empty Air kerma values.
2.1.3 (10 ~ 60) kVX ray radiation device shall comply with the magnitude of reproduction and delivery requirements. By changing the current and distance methods to extend the range (0.01 ~ 0.1) Gy/min.
2.1.4 (10 ~ 60) kVX ray air kerma national benchmarks reproduce air kerma values are not extended Degree of certainty as. Urel = 0.56%, coverage factor k = 2 (if not specified, the following are the same).
2.2 (10 ~ 60) other standard device kVX ray air kerma transmission reference (10 ~ 60) kVX ray air kerma by the reference radiation device fitted with an alternative method to the standard therapeutic levels Position, the level of the standard diagnostic apparatus, protective levels of standard equipment transfer value.
3 measurement standard Standard measuring instruments and radiation dosimeter by the standard device components. Standard radiation dosimeter by normal means Alternative Working-class dosimeters transfer value.
3.1 standard therapeutic levels of X-ray apparatus
3.1.1 X-ray treatment level standard equipment by the treatment level standard dosimeters and treatment of X-ray radiation device composition.
3.1.2 treatment level standard dosimeter air kerma rate measurement range (0.01 ~ 10) Gy/min.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
How to Download JJG 2095-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
JJG 2095-2012
$165.00