JJG 2028-2021Verification Scheme of Measuring Instruments for Diffuse Transmission Visual Density(Black and White Density) (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for JJG 2028-2021 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Mandatory

Issue date

December 8, 2021

Implementation date

June 8, 2022

Scope

JJG 2028-2021 (Verification Scheme of Measuring Instruments for Diffuse Transmission Visual Density(Black and White Density)) is available as an English-translated PDF.

JJG 2028-2021 — This standard applies to the verification of optical transmission density measuring instruments.

It stipulates the purpose of the national standard of diffuse transmission visual density, the complete set of basic measuring instruments included in the standard, the metrological parameters of the standard, and the procedures for transferring the unit value of transmission density to the working measuring instrument by means of the working standard and standard, and specifies that it is not Degree of certainty and basic verification methods, etc.

Found what you need?

Document preview — JJG 2028-2021

National Standard of the People's Republic of China

ICS
17.180
Classification
A 60

Issued by: State Administration for Market Regulation

Contents

  • Introduction (II)
  • 1 Scope(1)
  • 2 Measurement basis(1)
  • 3 Metrics(2)
  • 4 Working Measuring Instruments(3)
  • 5 Diagram of the calibration system for diffuse transmission visual density (black and white density) measuring instruments (3)

1 Scope(1)

2 Measurement basis(1)

3 Metrics(2)

4 Working Measuring Instruments(3)

5 Diagram of the calibration system for diffuse transmission visual density (black and white density) measuring instruments (3)

Introduction

JJF1001 "General Metrology Terms and Definitions", JJF1032 "Terms and Definitions of Optical Radiation Metrology", JJF1059.1 "Evaluation and Expression of Measurement Uncertainty" and JJF1104 "Rules for Compiling Tables of National Metrology Verification System" Together they constitute the basic series of specifications that support the revision of the verification system tables:

This verification system table replaces JJG 2028-1989: Compared with JJG 2028-1989, except for editorial modifications, the main technical changes are as follows:

--- Modified the description and indicators of the national benchmark for diffuse transmission visual density (see 2.1);

--- Modified the indicators of the diffuse transmission visual density work benchmark (see 3.1);

--- Increased the description and indicators of the diffuse transmission visual density standard device (see 3.2);

--- Modify the description about the standard density sheet (see 3.3, 3:4, 3:5);

---Deleted the related content of optical wedge density;

---Modified the diffuse transmission visual density (black and white density) measuring instrument verification system diagram (see Chapter 5):

The previous version releases of this verification system table are as follows:

---JJG 2028-1989:

Diffuse transmission visual density (black and white density) Measuring Instrument Verification System Table

1 Scope

This verification system table is applicable to the verification of optical transmission density measuring instruments: It specifies the diffuse transmission visual density state the purpose of the benchmark, the complete set of basic measuring instruments included in the benchmark, the metrological parameters of the benchmark and the use of the working benchmark, Standard procedure for transmitting the value of a transmission density unit to a working measuring instrument, specifying its uncertainty and basic verification method law etc:

The verification system is composed of three parts: measuring reference instruments, measuring standard instruments and working measuring instruments:

Spectral conditions and geometric conditions of measuring instruments at all levels shall comply with GB/T 11501-2008 "Photographic Densitometer Part 3: Spectral Conditions", GB/T 11500-2008 "Photographic Density Measurement Part 2: Transmission Density Degree of geometric conditions "requirements:

2 Measurement basis

2.1 National benchmark for diffuse transmission visual density

2.1.1 National benchmark for diffuse transmission visual density is a device to reproduce diffuse transmission visual density: optical density the spectrum-corrected photodetector directly reads the transmitted luminous flux of the sample and the measured luminous flux when the sample moves out of the sampling hole of the measuring device the amount is then calculated according to the definition of transmission density [Equation (1)]:

DT=lg(1/tau) (1)

Among them, DT is the optical density; tau is the transmission factor, which is defined as the difference between the luminous flux phitau passing through the sample and the sample measured from the ratio of the measured aperture flux phij after the sampling aperture of the instrument leaves, that is, tau=phitau/phij (2) Then there are:

DT=lg(phij/phitau) (3) Optical density is a dimensionless quantity with a unit of 1: The measurement spectral condition of the national benchmark is the incidence of the lighting system the spectral function should be the function SH specified in GB/T 11501-2008; the spectral function of the detection system should be VT: country the measurement geometry of the home benchmark is an integrating sphere plus opal glass lighting, and a 9° cone angle for collection: So this spectral condition and the functional representation of the geometric conditions should be DT (90° opalescent glass; SH<=10°; VT): This optical density is called diffuse Transmission visual density: The sampling hole diameter of the reference device is 4mm: Its schematic diagram is shown in Figure 1:

2.1.2 The incident lighting system of the national benchmark is realized by the light source system with the fiber optic hemispherical transmitter as the core, mainly including Includes tungsten halogen lamps, axicon ellipsoid mirrors, fiber optic hemispherical emitters, and opal glass: Its diffuse transmission coefficient reaches 0:945, in the reflection factor of opal glass at 550nm wavelength is 0:55:

2.1.3 The detection system consists of a lens group designed using the imaging principle, a silicon photodiode with a V(lambda) correction filter, and and picoammeter, the nonlinearity is 1:002 in the range of (4×10-6~1×10-12)A:

2.1.4 The optical density measurement resolution of the whole system is 0:001, and the expanded uncertainty is U=0:003 (0

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download JJG 2028-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 2028-2021

$150.00