JJG 2015-2013Verification Scheme of Measuring Instruments for Pulse Waveform Parameter (English PDF)
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for JJG 2015-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJG 2015-2013 (Verification Scheme of Measuring Instruments for Pulse Waveform Parameter) is available as an English-translated PDF.
JJG 2015-2013 — This standard applies to money transfer pulse waveform parameters measuring instruments.
Found what you need?
Document preview — JJG 2015-2013
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
- Replacing
- JJG 2015-1987
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Terms and definitions (1)
- 2.1 Kick-out pulse (1)
- 2.2 NTN calibration technology (1)
- 3 Overview (1)
- 4 Pulse waveform baseline measurement instruments (1)
- 4.1 Pulse waveform parameters reference means consisting of (1)
- 4.2 National measurement reference measurement range (2)
- 4.3 National baseline measurement uncertainty (2)
- 5 Pulse waveform measurement apparatus (2)
- 5.1 Standards of measurement (2)
- 5.2 Sampling oscilloscope calibration device (2)
- 5.3 Standard pulse amplitude generator (2)
- 5.4 High-bandwidth digital real-time oscilloscope (2)
- 5.5 Oscilloscope Calibrator verification device (2)
- 5.6 Sampling oscilloscope (3)
- 5.7 Pulse voltmeter (3)
- 5.8 Oscilloscope Calibrator (3)
1 Scope (1)
2 Terms and definitions (1)
2.1 Kick-out pulse (1)
2.2 NTN calibration technology (1)
3 Overview (1)
4 Pulse waveform baseline measurement instruments (1)
4.1 Pulse waveform parameters reference means consisting of (1)
4.2 National measurement reference measurement range (2)
4.3 National baseline measurement uncertainty (2)
5 Pulse waveform measurement apparatus (2)
5.1 Standards of measurement (2)
5.2 Sampling oscilloscope calibration device (2)
5.3 Standard pulse amplitude generator (2)
5.4 High-bandwidth digital real-time oscilloscope (2)
5.5 Oscilloscope Calibrator verification device (2)
5.6 Sampling oscilloscope (3)
5.7 Pulse voltmeter (3)
5.8 Oscilloscope Calibrator (3)
6-pulse waveform working measuring instruments (3) 7 pulse waveform parameters Measuring Instruments System Tables Diagram (3)
Introduction
The preparation of the Verification System is based JJF1001-2011 "common measurement terms and definitions", JJF1002-2011 "National verification procedures writing rules" and JJF1071-2010 "National Calibration Specifications writing rules" in the claim write. The verification system in substitution for 1987 by the National Measurement Bureau issued JJG 2015-1987 "pulse waveform parameters meter Amount after verification system. " Compared with JJG 2015-1987, in addition to editorial changes outside the main technical changes are as follows.
--- Pulse waveform parameters of technical indicators to improve the national benchmark for the September 2006 AQSIQ approved Nose-to-Nose utilize calibration technology to establish national baseline pulse waveform parameters of technical indicators;
--- Removed the timing generator pulse waveform parameter value transfer system has been unusual standard equipment;
--- Added Oscilloscope Calibrator and other standard equipment;
--- Refresh the kind and amount of pulse waveform parameters standards of measurement and pulse waveform parameters metrology instruments Value transfer relationship.
Pulse waveform parameter measuring instruments Verification System
1 Scope
The verification system applicable to money transfer pulse waveform parameter measurement apparatus, which includes a pulse waveform parameter measurement Reference equipment, standards of measurement pulse waveform parameter value passed until the waveform parameters between the measuring instruments work Uncertainty relations, money transfer and money transfer method when requirements. In carrying out the calibration, but also as the traceability in accordance with.
2 Terms and definitions 2.1 kick-out pulse Two sampling oscilloscope input docking, one of the built-in DC bias sampling oscilloscope for sampling by an Sampling head toward the end of the connector pulse input.
2.2 NTN calibration nose-to-nosecalibrationprocedure the use of three sampling oscilloscope twenty-two butt, kick-out pulse results of three measurements simultaneous responder system Cheng group, and then deconvolution impulse response determined for each sampling oscilloscope, enabling sampling oscilloscope rise time calibration Technology.
3 Overview
Pulse waveform parameters through time domain measurement method to measure the pulse waveform of the transient response of a set of parameters, including pulse Characterizing waveform parameters and characteristics of the system rise time, pulse amplitude, overshoot. The reference pulse waveform parameters by NTN school Pulse rise time to establish quasi-technical parameters of the measuring system and pulse amplitude measurement system components. Using the reference system Reproduce and save the waveform parameters by means of standard measuring instruments deliver a pulse waveform parameter value to the work of measuring instruments, to ensure that the magnitude of the pulse waveform parameters unity.
4 pulse waveform baseline measurement instruments 4.1 pulse waveform parameters reference device component 4.1.1 pulse rise time measuring device. it consists of three 50GHz digital sampling oscilloscope composition using NTN (Nose-to-Nose) calibration technology to reproduce the magnitude of the reference pulse rise time parameter measurement system.
4.1.2 pulse amplitude measuring device. AC-DC pulse amplitude precision measurement method by the sampled digital voltmeter and other equipment consisting of Means.
Supporting devices 4.1.3 pulse waveform parameters reference system. not leveled sine amplitude flatness characteristic measurement apparatus, pulse Chong interval measuring devices.
4.1.4 pulse waveform parameters to achieve the baseline measurement reproducibility and the basic unit of measure is not saved, but indirectly traceable to the basic unit of measure. current Units (ampere) and time units (seconds).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
How to Download JJG 2015-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 2015-2013
$165.00