Scope
JJG 2009-2016 (RF and Microwave Power Measuring Instruments) is available as an English-translated PDF.
JJG 2009-2016 — This standard is applicable to the transmission of radio frequency and microwave power, including the transmission of radio frequency and microwave power from the radio frequency and microwave power measurement standard through the measurement standard to the working measuring instrument, the amount of transmission method and the measurement of the transmission capacity.
Found what you need?
Document preview — JJG 2009-2016
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
- Replacing
- JJG 2009-1987
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Measurement basis (1)
- 3.1 Name and magnitude (1)
- 3.2 Power Benchmark Uncertainty (1)
- 3.3 Transfer method (1)
- 4 Metrological standards (1)
- 4.1 Name (1)
- 4.2 Volatility and Uncertainty (2)
- 4.3 Transfer method (3)
- 5 Work measuring instruments (3)
- 5.1 Name and measurement range of typical work measuring instruments (3)
- 5.2 Power deviation of work measuring instruments (3)
- 6 RF and microwave power measurement equipment test system block diagram (4)
1 Scope (1)
2 References (1)
3 Measurement basis (1)
3.1 Name and magnitude (1)
3.2 Power Benchmark Uncertainty (1)
3.3 Transfer method (1)
4 Metrological standards (1)
4.1 Name (1)
4.2 Volatility and Uncertainty (2)
4.3 Transfer method (3)
5 Work measuring instruments (3)
5.1 Name and measurement range of typical work measuring instruments (3)
5.2 Power deviation of work measuring instruments (3)
6 RF and microwave power measurement equipment test system block diagram (4)
Introduction
The test system table is based on JJF1001-2011 "General measurement terms and definitions" and JJF1104-2003 "country JQG2009-1987 is based on the preparation of the rules for the preparation of the system.
And JJG 2009-1987 "radio frequency and microwave power measurement instrument test system table" compared to the main content is like Under change.
--- According to the existing national radio frequency and microwave power reference value transmission capacity, will test system table work the upper limit of the frequency is extended to 75GHz, and the power range of the measurement standard and the working metering device is extended to 500W.
--- the original three sets of power reference band narrow, complex operation, not easy program control, is no longer used. Original system
Table 3cm power base using calorimeter technology, the new four sets of power benchmarks are used microcalorimeter technology, after
Than the former has the advantages of simple operation, low uncertainty. In view of the current international comparison, the domestic value of the most in the transmission High power level of 10mW, and the measurement standard in the 10mW power level with a stable value, measurement of high signal to noise ratio , The upper limit of the power level of the four sets of new power references is set to 10 mW. For more than 10mW Power level, the measurement department at all levels can be based on the situation, the use of range expansion method, to solve their own.
--- refer to the China Institute of Metrology published National Calibration and Measurement Capability (CMC) table to adjust the part Frequency band technical indicators.
In the measurement standard transfer method, the complicated method of power equation method and reflectometer method is deleted.
The test system table of the previous release.
--- JJG 2009-1987.
Radio frequency and microwave power measuring instrument verification system table
1 Scope
The test system table applies to radio frequency and microwave power transfer, including radio frequency and microwave power from the radio frequency and Microwave power measurement basis through the measurement standard to the work of measuring instruments of the transfer relationship, the value of the transfer method and the value of transmission when the measurement capacity. In carrying out the calibration, but also as a basis for the value of traceability.
2 reference file
Standard Terminology and Definitions for JJF1001 JQF1188 Terminology and definitions of radio metrology nouns Evaluation and Representation of Measurement Uncertainty in JJF1059.1 where the date of the reference file, only the date of the version applies to the system table, all do not note the date of the reference text , The latest version (including all modifications) applies to this system.
3 measurement basis
3.1 name and value
Radio frequency and microwave power (hereinafter referred to as power) measurement benchmark (hereinafter referred to as benchmark), including coaxial power reference group and the waveguide power reference group. The magnitude of the power reference reproduction is the effective efficiency of the RF and microwave thermistor mounts.
3.2 Power Benchmark Uncertainty
3.2.1 Coaxial power reference group N-type coaxial power reference, frequency. 0.01GHz ~ 18GHz, power. 1mW ~ 10mW, uncertain 0.1% (k = 2).
3.2.2 Waveguide power reference group WR-28 waveguide power reference, frequency. 26.5GHz ~ 40GHz, power. 1mW ~ 10mW, Fixed 0.1% (k = 2);
WR-22 waveguide power reference, frequency. 33GHz ~ 50GHz, power. 1mW ~ 10mW, uncertain 0.1% (k = 2);
WR-15 waveguide power reference, frequency. 50GHz ~ 75GHz, power. 1mW ~ 10mW, uncertain 0.1% (k = 2).
3.3 delivery method
Power reference using DC replacement technology, calorimetric technology for various forms of RF and microwave thermistor power (Hereinafter referred to as thermistor block) the effective efficiency of the assignment, to the lower level of measurement for the value of transmission.
4 measurement standards
4.1 Name
4.1.1 Type N Thermistor Block
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
How to Download JJG 2009-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1151-2025 — Verification Regulation of Liquid Chromatograph-Atomic Fluorescence Spectrometers
JJG 1204-2025 — Verification Regulation of Electronic Price Computing Scales(for Trial Implementation)
JJG 579-2025 — Trial Case Lenses
Secure payment via Stripe
Payments accepted
JJG 2009-2016
$145.00